Ductile iron gate valve 2‘’-12‘’
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Packaging & Delivery
Packaging Detail: | plywood case |
Delivery Detail: | 30days after recieve your deposit |
Specifications
1.Face to Face:BS5163
2.Material: Cast iron
3.Nominal Pressure: PN16
4.Stem Material:Stainless Steel
5.Flange End:2"-24''
Product Description
rising stem gate valve, metal seated gate valve
BS5163 gate valve
Cast iron gate valve
Rising stem gate valve,
Product name:
Rising stem gate valve
BS5163 gate valve
Cast iron gate valve
OS&Y gate valve
BS rising stem gate valve
BS gate valve
resilient seat gate valve
Material
Body: CI or DI
Disc: CI or DI
Seat: Brass/Bronze
Stem: stainless steel
Standard
Face to face: BS5163:1986,BS5150
Flange: BS 4504&BS10table E or D
Pressure
PN10/16
- Q: Function of signal butterfly valve and gate valve
- The signal butterfly valve applies to petroleum, chemical, food, medicine, papermaking, water and electricity, ships, water supply and drainage, smelting, energy and other system pipelines. It can be used as regulating and throttling devices in a variety of corrosive, non corrosive gases, liquids, semi fluids, and solid powder pipelines and containers. It is widely used in high buildings, fire protection systems and other piping systems that need to display valve switching status.
- Q: What are the meaning of the cast rigid gate valves z41h-16c?
- According to the provisions of the JB/T 308-2004 valve type programming method:Z== gate valve4== flange connection1== rigid single gateH== sealing surface material: Cr13 stainless steel16== pressure rating: 1.6MPaC== body material: carbon steel
- Q: Why does the fire hydrant box in the air defense area need to be added with gate valves?
- when the envelope from the introduction of civil air defense, air defense should be set in the side of retaining structure; through the protection unit between the closed wall, should be installed in the pipe walls on both sides of the door closed;2 protection valve nominal pressure shall not be less than 1.OMPa;
- Q: What does gate valve do?
- Valve in the pipeline can only be fully open and fully closed off, can not be adjusted and the throttle. Gate valve is a valve used in a wide range, generally more than 50mm caliber DN block device is selected it, sometimes cut off very small aperture devices are used to gate valve, gate valve is used as cut-off media, when in full flow through the whole, when the media is running a minimal pressure loss. Gate valves are normally used in situations where they do not need to be frequently opened and closed, and the gate is fully open or fully closed. Not used as an adjustment or throttling. For high speed moving medium, the gate can cause the vibration of the gate under the condition of partial opening, and the vibration may damage the sealing surface of the gate and the valve seat, while throttling will cause the gate to suffer the erosion of medium.
- Q: What is the difference between Z41X gate valve and Z45X gate valve?
- There is no difference in function. The two models are mainly made of different sealing materials,
- Q: What are the common standards for gate valves?
- 1, product standardsGeneral purpose valves, flanged connections, iron gate valves, GB/T 12232-2005General requirements for steel valves GB/T 12224-2005"Steel flat gate valves for pipelines" JB/T 5298-91Inspection and test of valves. JB/T 9092-1999Standard for safety evaluation of drinking water distribution equipment and protective materials GB/T 17219-1998
- Q: What's the difference between the knife gate valve and the stop valve?
- Standard light valve professionals to answer for you, gate valve refers to the closure of parts (gate) along the central line of the vertical direction of moving valve. The gate valve is mainly used for cutting in the pipeline. The valve is a valve with a very wide, cutting device general caliber DN = 50mm use it, sometimes a small diameter cutting device also use valve, gate valve has the following advantages:Fluid resistance is small.
- Q: What is the difference between gate valve and gate valve? Is it the same valve?
- The same, very few people call gate valve, all call gate valve.
- Q: What is the difference between the cut-off valve and the gate valve?
- When opening and closing, the valve core and valve seat sealing surface always contact and rub each other, so the sealing surface is easy to wear, the valve is close to shut down, the pressure difference between the pipe is very large, so that the sealing surface wear more serious.Gate valve and stop valve advantages and disadvantages:Valve is the advantages of small flow resistance, the media can flow in two directions, but there are tall, complex structure, sealing surface easy to wear shortcomings. The flow resistance of the gate valve is 3-5 times that of the gate valve. Open and close to shut down in order to seal the valve, the valve is completely closed when in contact with the sealing surface, the sealing surface wear is very small, because the flow of the main actuator with large valve should pay attention to adjust the torque control mechanism.
- Q: What does "Z45W-10T" mean?What does each letter stand for?
- For type PN10 Z45W Brass Gate ValvesZ is the valve type code, which represents the gate valve;Driving mode is hand wheel (code name omitted);4 is the connection form code, which represents the flange;5 is the gate valve structure form code, represents for the dark pole wedge rigid single gate;
Send your message to us
Ductile iron gate valve 2‘’-12‘’
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords