• Concrete Pump Truck 5r47m Portable Truck Mounted System 1
  • Concrete Pump Truck 5r47m Portable Truck Mounted System 2
Concrete Pump Truck 5r47m Portable Truck Mounted

Concrete Pump Truck 5r47m Portable Truck Mounted

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 PCS
Supply Capability:
1500 PCS/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Concrete Pump Truck 5r47m Portable Truck Mounted 

Product Details

Basic Info.

Model NO.:HZZ5381THB

 

Transmission Type:Manual

Condition:New

 

Overall Dimensions(Mm):12600X2500X3980

Total Loading Mass(Kg):38500

 

Concrete Displacement(M3/H):120

Engine Power (HP):390

 

Hydraulic System:Germany Rexroth

Mutiple Valve:Germany Harwe

 

Remote Controller:Germany Nbb

Power:Diesel

 

Emission Standard:Euro 3

Truck Type:Cargo Truck

 

Export Markets:Global

Additional Info.

Trademark:China. Jinggong

 

Packing:Naked

Standard:ISO9001, CCC

 

Origin:Zhejiang. China

HS Code:8705909090

 

Production Capacity:2units/Month

Product Description


 




Model No.
5R47

Pumping Unit
 

Output capacity (m3/h)
120

Concrete pressure(bar)61-76

Concrete cylinder(mm)230x2000


Mixer Hopper Capacity (L)

550
Boom SectionBoom folding type"R"

Boom unfolding height (m)8.9

Boom vertical reach (m)47.0

Boom horizontal reach (m)42.1

Boom depth reach (m)33.4

Boom rotation (o)370

Concrete pipe (mm/inch)125/5''

Number of boom sections5

Angle between boom sections (o)91/180/180/180/265
StabilizerStabilizer opening width of outriggers (m)"I"

Maximum opening width of outriggers (m)10.2
Chassisaccording to customer requirements, pumps can be mounted on 8x4 chassis from Europe, Japan or chinese manufactures.

Concrete Pump Truck 5r47m Portable Truck Mounted

Concrete Pump Truck 5r47m Portable Truck Mounted


Q:What is the working principle and structure of a concrete pump truck?
The fabric device is a boom type, can be in a certain range of vertical and horizontal direction of the transport and watering concrete, can reduce the support staff, reduce labor intensity, improve the construction efficiency, and make the concrete evenly, smooth, dense, improve the quality of concrete
Q:What is the lubrication of the concrete pump before it is transported to the concrete?
Concrete pump to transport concrete before the pipeline lubrication
Q:What are the drawbacks of concrete pump gate valve and S pipe valve?
In addition to the use of gate valve delivery, but also requires the vertical transport pipeline in front of the installation of a horizontal transmission pipe section, the length of concrete lifting height of 1 /
Q:What kind of driver's license does the concrete pump need?
Driver's license to use B2 card, qualification certificate can be transported with ordinary goods, no need to use special vehicle qualification certificate.
Q:What is the difference between the construction of a concrete pump and a concrete distributor?
Pumps require concrete and easy to work, concrete admixture to add pumping agent.
Q:How the calculation of the discharge speed of concrete pump truck
as well as mixing and mixing station mixing speed, There is also a condition that is the quality of concrete
Q:How much concrete can the pump pump pump for an hour?
On the other hand reflected in the performance of the concrete pump in the construction of the proposed Futian Liza pump, Futian Leisha pump using large diameter, long stroke of the cylinder and the smaller suction angle of the perfect combination of technology, the maximum pumping
Q:Why does concrete pump truck need pipe?
Over the past few decades, ready-mixed concrete industry throughout the country has been using water and mortar on the concrete pump for pipe operation, the result is neither economic nor consistent with the current low-carbon environmental protection and energy saving concept.
Q:What is the role of the one-way valve at both ends of the main cylinder of a concrete pump truck?
Oil circuit to open the one-way valve does not work to facilitate the piston back to the cleaning room to facilitate the replacement of the piston.
Q:Why is my concrete pump often appear plugging phenomenon?
The first pumping, due to the larger pipeline resistance, this time should be low-speed pumping, pumping normal, may be appropriate to improve the pumping speed.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords