CFE Utility ESS 2580Kwh- 3440Kwh Battries in containers
- Loading Port:
- Shanghai
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1 watt
- Supply Capability:
- 10000 watt/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
l ≤ 1 hour: Maintenance and replacement time is less than 1 hour
l ≥ 90%: System charging and discharging efficiency>90%
l ≥ 6000 cycles: The battery cycle life under energy storage conditions exceeds 6000 cycles
l High-performance PCS: Using high-efficiency three-level topology, Germany's seventh-generation IGBT, the highest efficiency can reach 99.3%
l High configuration system: Integrate high-speed communication, power distribution and metering, AC output adopts 2-level controllable switch + passive protection
l Actively balanced BMS: Adopt high-current high-efficiency two-way active equalization technology to eliminate series losses caused by inconsistent batteries
l Active safety system: Adopt intelligent environment control to ensure the best battery temperature, The 9-level active safety system ensures that the fire protection is controllable.
l Intelligent power distribution system: Integrating high-speed communication, electric power distribution and metering, AC output adopts 2-level controllable switch + passive protection.
System nominal | |||
Rated power | 500KW | 1000 KW | 1000 KW |
Nominal capacity | 2580KWh | 3010 KWh | 3440 KWh |
Communication side | |||
Rated voltage | 380V | 380V | 380V |
Rated current | 759A | 1500A | 1500A |
Rated frequency | 50HZ | 50HZ | 50HZ |
Power factor | >0.98 | >0.98 | >0.98 |
Wiring | Three-phase three-wire | Three-phase three-wire | Three-phase three-wire |
Isolation transformer | 630KVA | 1250KVA | 1250KVA |
Inrush current | Less than 7 times | ||
Harmonic distortion rate | Less than 3% (secondary side of transformer) | ||
DC side | |||
Rated voltage | 768V | 768V | 768V |
Lower limit voltage | 600V | 600V | 600V |
Upper limit voltage | 876V | 876V | 876V |
Rated current | 650A | 1300A | 1300A |
Cell specifications | 280Ah | 280Ah | 280Ah |
Number of batteries | 2880 | 3360 | 3840 |
Number of modules | 180 | 210 | 240 |
Module specifications | 1P16S | 1P16S | 1P16S |
Actual capacity | 2580KWh | 3010KWh | 3440KWh |
Battery management | |||
Cluster battery | 12 | 14 | 16 |
Cluster unit | 12 | 14 | 16 |
Voltage accuracy | 0.002 | 0.002 | 0.002 |
Temperature accuracy | 0.01 | 0.01 | 0.01 |
SOC accuracy | 0.05 | 0.05 | 0.05 |
Power accuracy | 0.01 | 0.01 | 0.01 |
Cabinet | |||
Battery cabinet | 966*855*2400mm | 966*855*2156mm | 966*855*2156mm |
Control cabinet | 2000*600*700mm | 2000*600*700mm | 2000*600*700mm |
PCS cabinet | 1400*825*2180mm | 1400*825*2180mm | 1400*825*2180mm |
Air conditioning | |||
Installation method | Embedded | Embedded | Embedded |
Cold power | 30KW | 30KW | 30KW |
Fire control | |||
Fire fighting medium | Heptafluoropropane | ||
Spray method | Pipeline (battery room) | ||
Fire detection tube (PCS room) | |||
Communication Interface | |||
Wireless | 2G,1 minute update | ||
Wired | Network, 5 seconds update | ||
System cycle life | >6000Cycle(25℃) | >6000Cycle(25℃) | >6000Cycle(25℃) |
Capacity availability | >80% | >80% | >80% |
Weight | <20T | <41T | <45T |
Structure size | 12.192m*2.438m*2.591m | 12.192m*2.438m*2.591m | 12.192m*2.438m*2.591m |
- Q: How is the capacity of the battery defined?
- 100AH capacity of the battery, fully charged after the 100A current discharge can be an hour to put the power finished. 50A current is 2 hours put away! 20A is 5 hours! Of course this is the theoretical value, in fact it is impossible to have a constant current discharge.
- Q: What is the difference between a maintenance-free battery and a conventional battery?
- Lead-acid battery is composed of positive and negative plates, partitions, shell, electrolyte and wiring pile head and other components, the discharge of the chemical reaction is to rely on positive electrode active substances (lead dioxide and lead) and negative plate active substances (sponge Pure lead) in the electrolyte (dilute sulfuric acid solution) under the action, which plate grid, the traditional battery lead and antimony alloy manufacturing, maintenance-free battery is made of lead calcium alloy, the former with antimony, the latter with calcium, This is the fundamental difference between the two points.
- Q: What are the technical parameters of the battery?
- Usually the capacity of the power supply is expressed by kV · A or kW. However, as a power supply VRLA battery, the use of security (A · h) that its capacity is more accurate.
- Q: What are the hazards of battery over discharge?
- Crystalline conductivity is poor, and bulky, will clog the pores of the battery plate, affecting the battery electrolyte penetration and exchange, but also further increase the battery resistance, a long time will prevent the battery power and chemical energy Of the reversible conversion, resulting in poor recovery of the battery charge, the battery was seriously damaged, or even unable to repair until scrapped.
- Q: Maintenance-free battery how to detect it?
- Check the height of the electrolyte at least once a month. There is no mark line of the battery, the electrolyte added to the plate 10-15mm can be higher; there are two red line of the battery, the electrolyte can not exceed the red line above.
- Q: What battery does the van use?
- The battery is mainly composed of tube positive plate, negative plate, electrolyte, separator, battery compartment, battery cover, pole, injection liquid cover and so on. The electrode of the exhaust type battery is made of lead and lead oxide, and the electrolyte is an aqueous solution of sulfuric acid. The main advantage is the voltage stability, the price is cheap; the disadvantage is lower than the energy (that is, per kilogram of battery storage power), short life and routine maintenance frequently. Old ordinary battery life of about 2 years, and the need to regularly check the height of the electrolyte and add distilled water. However, with the development of science and technology, lead-acid battery life becomes longer and maintenance is also more simple.
- Q: What is a maintenanceable battery?
- It also has a shock, high temperature, small size, self-discharge characteristics. Life is generally twice the ordinary battery.
- Q: Battery 200ah / 104 what does that mean?
- This should be refers to 2V200AH battery 104, power with the 220V. Lead-acid battery nominal voltage is 2V / (each or monomer), but in fact will be higher than 2V, so the actual use and charging equipment for the matching will use 104, also useful 103, also useful 108 Only.
- Q: How does battery activation work?
- If the battery is charged, because the battery discharge itself, the active substance to activate, not add acid, but should be added pure water (no minerals and impurities in the water) is best steaming water, and now you Since the addition, you can use water to wash several times, and then use 1C current charge to 2.3 times. Then discharge, so repeated several times, will be better. So that you can remove the vulcanization.
- Q: Lead-acid battery how to maintain?
- Open the rubber cap, exposing the exhaust raft, you can see the battery inside, some of the battery exhaust cutting can be unscrewed.
Send your message to us
CFE Utility ESS 2580Kwh- 3440Kwh Battries in containers
- Loading Port:
- Shanghai
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1 watt
- Supply Capability:
- 10000 watt/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords