Product Description:

Quick Details

Condition:

New

Brand Name:

CNBM

Place of Origin:

JIA,china China (Mainland)

Use:

Room,room

Power Source:

Electrical

Power Type:

AC

Type:

Central Air Conditioners

Cooling/Heating:

Cooling/Heating

Certification:

CE,RoHS

Capacity (btu):

48000

COP:

3

EER:

2.15

Power (W):

4800

Voltage (V):

220

Model Number:

KFR-120QW/VS

color:

white

warranty:

18months

kind:

central air conditioners

voltage:

220

model:

KFR-120QW/VS

brand:

Chunlan

name:

ceiling mounted air conditioner for commercial

Packaging & Delivery

Packaging Detail:safe carton package for export
Delivery Detail:15days

Specifications

air conditioner
1.sim body embedded in ceiling,
2.Save mroe space
3.Harmonize with your decorated room
4.Comfortable

 air conditioner

 

ceiling mounted air conditioner for commercial

 

Product Description

 

 1.sim body embedded in ceiling,Save mroe space.Harmonize with your decorated room

 

2.High efficient filters keep the dust out to avoid feculent air .you can breathe freshly

 

3.the auto-lifting of air -inlet arill is remote controlled,no need for climbing high and convenient for maintenance(VL series does not have this function)

 

4.Operation centrum is manufactured with super quiter technologh and outdoor unit is installed faraway from room,Noises are isolated perfectly.

 

5.Branded compressor generates powerful enerygy and strong cooling and heating capacity,which can meet your request for temperature swiftly.

 

5,Warranty Policy:

 

We guaranty 18 Months warranty for the products.

 

A.Repair include:compressor/fan motor/control panel/Receiver modules,thermal controller and other spare parts.

 

B.Because all the quality issues we should bear the cost maintenance and spare parts.

 

One of the following does not belong to the scope of the repair,But fees may apply maintenance

 

1,Damages caused during the transportation,load,installation which made by upload, transportation ,installation principal.

 

2,During the debug,damages caused by inappropriate test behaviors should be on charge by the debug team.

 

3,After debugging is completed and the equipments can be work normally,any mistaken manual operations made by the users should be on charge for the damage.
4,Any movements,dissemble and repair /maintenance operated by other company or person which leads to damage 

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Air conditioning voltage is how many v?
General of the air conditioning is 220 volts single-phase three-phase 380 v
Q:Do you need frequency conversion for household air-conditioning
The working principle of the frequency converter compressor is always start non-stop, through different rotation speed to output different sizes of cold/heat, cold/heat, constant speed machine is a constant output depends on the compressor start and stop to control the temperature. The greatest characteristic of frequency converter, therefore, it is quiet, no compressor start and stop the mechanical noise, 2 it is accurate to 0.5 degrees, the temperature control and constant speed machine control range is 2 degrees, so the frequency conversion machine is especially suitable for use in the bedroom. Due to the frequency changer the price is expensive, decided to other room whether choose according to economic conditions. About energy-saving frequency converter, frequency converter with constant speed machine working mode is different, can't absolutely more energy-saving, frequency converter is used more long time to reflect and energy saving, so the energy-saving sex just select one of the reference factors of frequency converter, is not the main factor. Eer level low frequency changer is not as good as level high constant speed machine and energy saving.
Q:Machine evaporator dirt inside air conditioning and cleaning method
Fault condition: refrigeration effect is not good, almost feel wind speed. Fault analysis: air conditioning has been used for many years, is not installed at the beginning, so can be ruled out of design or installation errors (some air conditioning fluorine injection pressure is not enough or install valve tight can also result in refrigeration system failure, leading to poor cooling effect). Air conditioning use place as a knitting workshop, the air conditioning of electric control board and power supply, freon, and so on and so forth of illness, have not found the problem. When the air-conditioning outlet screen again found that the temperature on the high side, analysis may be caused by air volume is too small. It has already been carried out on the air conditioning of electric control board, the cause of air volume small also may be a dirty wall motor fault or evaporator. Through layers of screening and found the evaporator surface glue has a lot of wire cloth with soft nap, accompanied by frost. Debugging methods: completely remove dirt machine evaporator, bootable again, refrigeration effect is very ideal, and wind speed has returned to normal. Experience: some dust, soot, more environment was the cause of bad air conditioning refrigeration smudgy, therefore maintenance when this kind of air conditioning to adjust measures to local conditions, from the perspective of the peripheral environment, first screening condenser, evaporator, filter, such as whether the dirt, two, and capillary for the junction box, etc., this will make the repair work get twice the result with half the effort. Online to find information... Hope to have help!!!!!
Q:Air conditioning general under the condition of high and low pressure is normal?
This depends on the specific condition and the air conditioning refrigeration and heating of freon types, year-round operation under different indoor and outdoor temperature is not the same. Refrigerant R22, for example, if the cooling when outdoor temperature is 35, indoor temperature is 26, the air conditioning condensation temperature is about 50, corresponding to the high side pressure of 1.944 MPa, evaporation temperature of 6 degrees, corresponding to the low voltage side pressure of 0.6028 MPa. When heating, high and low pressure almost 1.3557 MPa and 0.5314 MPa.
Q:Can air conditioning filter pm2.5
Filtering, very serious tell you, I am make the test, compare to understanding membrane filter and filter. So in haze weather, had better not open air conditioning, especially not to open the ventilation mode (some called air conditioning to health model, with a green leaf said), or you and haze weather open window is an effect. If 2.5 is severe pollution in winter, you go to sleep at night don't open air conditioning, especially for children. If you feel cold, rather than oil, and don't open air conditioning.
Q:Air conditioning can not open 24 hours a day. Air conditioning will not bad ah
Had better not open air conditioning, because not ventilated, have many kinds of diseases. General feeling is not too hot in the day time to shut down, and then open the window ventilation, air conditioning open not bad. Can't do that, open air conditioning no effect after the Windows open, the cold air will be blown out, so you have to open air conditioning period of time, turn off the air conditioning in the morning and dusk, open the window, if too much electricity to burn your house is open for 24 hours all day, but it would definitely be sick
Q:Household air conditioning separate-bodied air-conditioners can use hanging way
Hang it is hard to think of, the machine is shaking, the earthquakes are, expansion of loose, mainly in doubt about the quality of the now If possible, the best is the concrete casting is there is a corresponding structure hanging out
Q:Buy a few P good sitting room buy a air conditioning?
Every room needs to be alone with a computer, not much room to share, not because each room air circulation, so the effect cannot be Shared. The basics of air conditioning of choose and buy: The output power of 1, refrigerating capacity, air conditioning, and must choose according to room size, the effect can be ensured, and manufacturer's request for an average of 200 watts/square meters. 18 square meters room, for example, requires the capacity 3600 watts, can buy a standard 3500 watts of machines on the market, or 35 machine, or 1.5 machine. With two digits in the type of air conditioning, KFR35GW / * * *, for example, is the machine capacity 3500 watts. Horse is the input power unit, it with simple conversion formula between the output power of 1 = 2500 watts refrigerating capacity. Refrigerating capacity choice is the main performance of air conditioning, refrigerating capacity partial bigger effect is good, the capacity is too small, low cost, but the effect is poor, more power consumption. Refrigerating capacity is basically hang up within 2 horse, more than 2 horse is basically a ark. 2, can effect comparing level: air-conditioning energy saving, the machine type annotation the Numbers below. Eer = refrigerating output/input power, the refrigerating capacity of the machine, the same old standard before June of this year has eer grade 1-5, 3.4 3.2 3.0 2.8 3.2, the new standard after June 1-3 grade 3.6 3.4 3.4. 1.5 horse machine refrigerating capacity is 3500 watts, for example, level 1 machines consumed power is 3500/3.6 = 976 watts of energy efficiency, the machine level is 3500/3.2 = 1094 watts, the consumption of grade 1 machine than 5 small 1094-976 = 1094 watts, that is to say, the compressor working continuously for an hour, a level 1 machine is less than level 3 machine power consumption 0.118 degrees. Level 1 machine is the most energy saving of energy efficiency, but also the most expensive price, from the perspective of performance test
Q:Air conditioning use how long and snow?
1, missed to add, add fluoride regardless of three to five years. Just missed to add, that is afraid of you just bought not used, as long as the fluorine a leak that must have to add to the refrigeration. 2, because of the fluorine is easy to miss, the fear of the air conditioning in the copper tube, especially the corner and junction, or even a little crack defects such as sand holes, fluorine would be in a very short period of time all miss! 3, air conditioning in the selection of quality in the process of manufacturing may never add fluoride or add fluoride is relatively long some shorter conversely some useless to a summer even missing. 4, leaking air conditioning is it possible to have fluorine: one is to look at the presence of refrigeration, the refrigeration effect how? 2 it is to see the fan blow an outdoor wind is cold, if boot in cooling mode, the fan blowing outward or outdoor air cooling, it can be omitted to fluorine. Three is to see whether the air conditioning in the use of water, without running water, that can be omitted to fluorine, four is After listening to air conditioning in the use of stop the moment, there are no water in the machine using sound, not possible Is the leakage fluorine. (above whether air conditioning leakage fluorine in fact is not very accurate air conditioning not refrigeration not only is it a possible leakage fluorine also cause air conditioning or refrigeration is bad not many such as compressor is broken filter clogging and so on.)
Q:How to choose home air conditioning
In accordance with the relevant provisions of the state: "air conditioning within 7 days from the date of sold, such as performance failures occur, consumers can choose to return, within 15 days from the date of sale can choose to replace the same model with the specifications of the air conditioning", but in the air conditioning sales season, you're likely to hit the "goods, is not the first to open". If the arrival of the goods and install time later than make out an invoice for several days, you will be delayed a few days in virtually found a claim on the failure, precious time, and even lose some of 3 packets of rights and interests. Before consumer is buying air conditioning, therefore, be sure to ask for air delivery to distributor and installation time, even with Ming on the shopping vouchers.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range