• Ceiling Cassette Type Air Conditioner 24000BTU 2 Ton  KFR-70QW System 1
  • Ceiling Cassette Type Air Conditioner 24000BTU 2 Ton  KFR-70QW System 2
  • Ceiling Cassette Type Air Conditioner 24000BTU 2 Ton  KFR-70QW System 3
Ceiling Cassette Type Air Conditioner 24000BTU 2 Ton  KFR-70QW

Ceiling Cassette Type Air Conditioner 24000BTU 2 Ton KFR-70QW

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
20 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

 

Quick Details

Condition:

New

Brand Name:

CNBM

Place of Origin:

Jiangsu China (Mainland)

Use:

Room

Power Source:

Electrical

Power Type:

AC

Type:

Ceiling

Cooling/Heating:

Cooling/Heating

Certification:

CB,CE,EMC,RoHS

Capacity (btu):

24000

COP:

2.8

EER:

2.8

Power (W):

2600

Voltage (V):

220

Model Number:

KFR-70QW

Pipe Size:

3/8" + 5/8"

Condenser:

Pure Copper

Connecting Pipe:

Pure Copper

Cable:

4m

Compressor type:

Rotary

Loading Quantity:

120sets (40HQ)

Application Area:

40-50m3

Packaging & Delivery

Packaging Detail:Carton Box Packing
Delivery Detail:30-45 days after receiving down payment

Specifications

Ceiling Cassette air conditioner :
1, R22/R410a
2, 18000BTU 2ton;
3, Cooling only/Cooling& Heating ;
4, 220V 50HZ/60Hz

Ceiling Cassette Air Conditioner 24000BTU 2ton

1) Reliable quality---professional assembling and sufficient test, defective rate below 0.05%.

2) High quality compressors and parts with guarantee;.

3) Delivery: Within 45days after confirming the L/C or T/T swift copy.

4) Certificate--- CE, RHOS,MEPS, SAA, C-TICK, EMC, BV, SGS, ISO9001,SAA,CB, etc..

5) Compressor Brand: CHUNLAN, TOSHIBA, RECHI, HITACHI

6) 1% free parts of the total FOB amount.

7)OEM service.

Q: ?the home of air conditioning ark of wire is to use a few square?
Copper wire safety calculation method is: 2.5 mm2 safety carrying capacity of copper power cord - 28 a. 4 mm2 safety carrying capacity of copper power cord - 35 a. The safety of the 6 square mm copper power cord carrying capacity - 48 a. 10 square mm copper power safe carrying capacity - 65 a. The safety of the 16 mm square copper power cord carrying capacity - 91 a. 25 mm square copper the safety of the power cord carrying capacity - 120 a.
Q: Are there any of household air conditioning fresh air?
Yes, claims to have more qigong can be automatically.Is worse than a few hours to open a window, each window as fast as more than 10 seconds for air, more fully.
Q: Electric power is generally how many watts family air conditioning?
This is related to the specifications of the air conditioning, the general window machine from 800 w to 2000 w, hang up the general from 1200 w to 2500 w, ark general 2500 w ~ 4500 w. This is just an approximate figure, if you have auxiliary heating, power larger; Household central air conditioning power is greater.
Q: Household air conditioning refrigeration quality measure standard is what?
Summer air conditioning refrigeration standard is: air-conditioning electricity work half an hour later, the temperature of the outlet should be about 10-15 degrees below the temperature of the inlet to the normal. Know, isn't it?
Q: How do I clean the evaporator coils on my air conditioner?
Cleaning the evaporator coils on your air conditioner is an important maintenance task that can greatly improve the efficiency and performance of your unit. Here's a step-by-step guide on how to clean the evaporator coils: 1. Turn off the power: Before you start cleaning, ensure that the power to your air conditioner is turned off. This is crucial to avoid any accidents or injuries during the cleaning process. 2. Remove the access panel: Locate the access panel on your air conditioner unit. This panel usually covers the evaporator coils. Use a screwdriver or any required tools to remove the panel gently. 3. Inspect the coils: Once the access panel is removed, inspect the evaporator coils for any signs of dirt, dust, or debris buildup. This buildup reduces the efficiency of the coils and can lead to poor cooling performance. 4. Clean the coils: Use a soft brush or a vacuum cleaner with a soft brush attachment to gently clean the coils. Be careful not to bend or damage the delicate fins of the coils. Brush in the direction of the fins to remove any dirt or debris. 5. Apply a cleaning solution: For stubborn dirt or grime, you can create a cleaning solution by mixing equal parts water and vinegar. Using a spray bottle, apply this solution to the coils and let it sit for a few minutes to loosen any buildup. 6. Rinse the coils: After the cleaning solution has had time to work, rinse the coils thoroughly with water. You can use a spray bottle or a garden hose for this step. Ensure that the water pressure is not too high to avoid damaging the coils. 7. Allow the coils to dry: Once rinsed, allow the coils to air dry completely. This may take a few hours, depending on the humidity in the area. Make sure the coils are completely dry before reassembling the unit. 8. Reassemble the unit: Once the coils are dry, reinstall the access panel securely. Ensure that all screws or fasteners are tightened properly. 9. Restore power and test the unit: Finally, turn the power back on and test the air conditioner to ensure it is functioning properly. Check for any changes in cooling performance or unusual noises. Regularly cleaning the evaporator coils is essential for maintaining the efficiency and longevity of your air conditioner. It is recommended to clean the coils at least once a year, or more frequently if you live in a dusty or humid environment. If you are unsure or uncomfortable performing this task yourself, it is best to seek professional help from a qualified HVAC technician.
Q: What type of refrigerant home air conditioning?
General fixed frequency machine is to use traditional R22, frequency changer now multi-purpose R410A
Q: How do I prevent ice buildup on my air conditioner coils?
To prevent ice buildup on your air conditioner coils, there are a few steps you can take: 1. Regularly clean and maintain your air conditioner: Make sure to clean the filters, evaporator coils, and condenser coils regularly. Dust, dirt, and debris can accumulate on the coils, reducing airflow and causing ice formation. Use a soft brush or a vacuum cleaner to remove any buildup. 2. Ensure proper airflow: Check that all vents and registers are open and unobstructed. Restricted airflow can cause the evaporator coils to become too cold, leading to ice formation. Additionally, ensure that there are no furniture or objects blocking the airflow around the indoor and outdoor units. 3. Check for refrigerant leaks: Low refrigerant levels can cause the evaporator coils to freeze. If you notice ice buildup frequently, it may be a sign of a refrigerant leak. In such cases, it is advisable to call a professional HVAC technician to identify and fix the leak. 4. Maintain a suitable thermostat setting: Adjust your thermostat to a temperature that is not too low. Extremely low temperatures can cause the evaporator coils to freeze. Aim for a comfortable temperature range to prevent ice buildup. 5. Use a programmable thermostat: A programmable thermostat can help regulate the temperature and prevent the system from running excessively, which can lead to ice formation. Set the thermostat to maintain a consistent temperature and avoid drastic temperature fluctuations. 6. Keep the area around the outdoor unit clean: Ensure that the outdoor unit is free from debris, such as leaves, grass, or dirt. Clear any vegetation or other obstructions around the unit to allow proper airflow. 7. Schedule regular maintenance: It is advisable to have your air conditioner inspected and serviced by a professional technician at least once a year. They can identify any potential issues and perform necessary maintenance to keep the coils clean and prevent ice buildup. By following these preventive measures, you can minimize the risk of ice buildup on your air conditioner coils and ensure optimal performance of your cooling system.
Q: Air conditioning use how long and snow?
Air conditioning how long need to add fluoride is a direct relationship between the and the installation of air conditioning, installation of good a don't need to add five to six years. Your air conditioning not refrigeration also is not necessarily the lack of fluorine. If you can check our before please maintenance workers to: 1. Look at the air filter dirty don't dirty 2. Let me check if the voltage is normal. 3. See if both inside and outside fan operation. 4. Listen to the outdoor compressor is working. If you check if the normal, wonder if leakage fluorine, before adding fluorine must check the freon missing from there, otherwise even added also use for a long time not appear the same problem again.
Q: How to choose and buy online ask yi tuo 2 air conditioning, is copying other people's answer, at last, it is not family air-condition is the central air conditioning, fission air conditioning? The general set of machine? Two sets of? The central air conditioning? Is not local tyrants.
Split type air conditioning is air conditioning set of machine is divided into inside and outside the machine, through online pipe online the types of air conditioning. Different from one-piece air conditioning, such as units. Yituo 2 air conditioners, refers to the outside air conditioning machine, towing chance within two lines. Is a kind of split type air conditioner
Q: Which master know why household air conditioning Wells, drilling Wells have what effect?
of course, it is definitely not like some people don't understand the principle that can increase the humidity (how much water flow in, how much water will be out, didn't reduce.) it will reduce indoor humidity. All of these and conventional air conditioning. A pump is available for three hanging air conditioning or 1-2 sets cabinet air conditioning used at the same time. It is more save electricity! (3 room 4-7 hours once electricity!!) Natural air conditioning geothermal air conditioning only water pump and air conditioning fan consumes little power, can effect comparing 1:25 above is one of the most energy saving air conditioning. Shallow groundwater is close to the local average atmospheric temperature throughout the year, with warm in winter and cool in summer seasons constant temperature characteristics, almost not influenced by air temperature

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches