AMB300-280G-T3 3 Phases Heavy Load Vector Frequency Converter

AMB300-280G-T3 3 Phases Heavy Load Vector Frequency Converter

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
10 unit
Supply Capability:
100 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Specifications

AMB300-280G-T3 3 phases heavy load vector frequency converter 
Unique fast DC brake 
Torque control 
CE, RoHs 
2 years warranty

Features:

• Control Mode: Sensorless vector control (SVC), V/F control, Open-loop torque control 
• Starting torque: 0.5Hz/150% 
• Speed adjusting range: 1:100(SVC) 
• Steady speed accuracy: ±0.5%(SVC) 
• Overload capacity: 60s with 150% of rated current, 1s with 200% of rated current 
• VF control, automatic torque increase, manual torque increase of 0.1%-30.0% 
• Stationary rotating motor parameters self-learning 
• Automatic energy-saving operation:Under load conditions,automatically optimize V/F curve, to achieve energy-saving operation 
• Automatic voltage regulation(AVR): Automatically keep the output voltage stable when input voltage fluctuating 
• Automatic limit on the run automatically during the current limit to prevent the frequent overcurrent fault trip 
• Automatically adjusted depending on the load characteristics of the carrier, automatically adjust the carrier frequency (optional)
• Sensorless vector control under the control of superior performance 
• Truly instantaneous normal operation after power-down 
• Vector under the control of low frequency and large torque and stable operation 
• Unique grid instantaneous power-down non-stop 
• Torque control operation 
• Unique fast DC brake

SPECIFICATION                                                                                        AMB300-280G-T3 3 phases heavy load vector frequency converter         AMB300-280G-T3 3 phases heavy load vector frequency converter

MODEL

AMB300-280G-T3

OUTPUT

DC VOLTAGE

0 ~ 380V

RATED CURRENT

520A

FREQUENCY RANGE

0 ~ 600Hz

OVERLOAD (max)

150% 1min, 200% 1s

INPUT

VOLTAGE RANGE

380V Triple-Phase (-20% ~ +15%)

FREQUENCY RANGE

50~60Hz (±5%)

CONTROL

&

RUNNING

SELF-ADJUSTING OUTPUT VOLTAGE

With the validity of AVR function, the output voltage is essentially unchanged when the input voltage changes

CONTROL MODE

Sensorless vector control (SVC), V/F, Open-loop torque control

SPEED ADJ. RANGE

1:100

OUTPUT FREQUENCY RESOLUTION

Digital setting: 0.01Hz;

Analogue setting: Maximum Frequency×0.1%

VOLTAGE/FREQUENCY CHARACTERISTIC

Two VF curve available to the choice

TORQUE BOOST

Auto Torque Boost; Manual Torque Boost

ACCELERATION &

DECELERATION CHARACTERISTICS

0.1s~3600s

BRAKING TORQUE

>20%

FREQUENCY SETTING INPUT

Keyboard, Computer, 0~10V, 0~20mA

INPUT COMMAND SIGNAL

Running, forward / reverse, jog, multi-speed, multi-stage acceleration and deceleration time, coast, step-by-step control, reset, voltage / current input signal switching

STANDARD FUNCTION

Auto-Retry Fault Recovery, Automatic torque boost, DC braking, Restarting at instantaneous power failure, Upper and lower limit in frequency bias, Frequency gain, carrier frequency adjustment, Adjustable acceleration and deceleration mode, Output frequency meter and ammeter, Multi-speed, PID control, RS-485 Interface

PROTECTION

Overvoltage, under-voltage, phase loss, over-current stall, current limiting, over-temperature, electronic thermal overload relays, overvoltage stall, data protection

EXTERNAL OUTPUT SIGNAL

Fault relay signals, 0 ~ 10V, 0 ~ 20mA signal and current signal, Programmable open collector output:

·Signal synchronization of the output frequency:

DC 0 ~ 20mA, 0 ~ 10V

·Signal synchronization of the output current:

DC 0 ~ 20mA, 0 ~ 10V

DISPLAY

KEYBOARD

Setup mode

Operation mode

Trouble mode

ENVIRONMENT

ALTITUDE

Indoor, Altitude below 1000m

REQUIREMENT

Free of Dust, Corrosive Gas, and direct sunlight

WORKING TEMP.    

-10 ~ +40°C

WORKING HUMIDITY

20%~90%RH (non- condensing)

VIBRATION

<5.9m/s2 (0.6g)

STORAGE TEMP.,

-25 ~ +65°C

INSTALLATION

Wall mounted

OTHERS

IP LEVEL

≤15Kw (IP20),  ≥18.5Kw (IP10)

COOLING

Forced air cooling

DIMENSION

1130*740*540mm ((L*W*H)

PACKING

142.5Kgs/Piece/Wooden Case

 

FAQ

What is the delivery time?

We can delivery the goods within 5 days after receiving your payment.


Q: 2 pole 0.75 kW motor can increase the speed through the inverter?
2-pole motor speed of about 2900 r / min or so, 4-pole motor speed of about 1400 r / min or so, which are in the case of 50HZ,
Q: How is the notebook with a power adapter?
The safest option is to choose the same type of notebook power adapter. When in some cases (the original adapter is too expensive or not available), you can select the operating parameters and output connectors and the original adapter.
Q: 6-pole motor, speed 8000 rpm, corresponding to the frequency converter output frequency is how much?
The synchronous speed of the motor is n = 60f / p P is the pole pair number, and f is the power supply frequency. The pole pair number of the 6 pole motor is 3. Therefore, f = n * p / 60 = 8000 * 3/60 = 400Hz.
Q: Variable frequency pump pressure in the very low flow instability, why?
From the performance curve, the flow becomes smaller, the combination of pressure and frequency adjustment flow will only stabilize the flow at a small value, the pressure will be reduced, because the work point will move down.
Q: Master Hello a machine requires 500 speed matching 6-pole motor frequency converter transferred to about 28HZ
The belt rotation is calculated by the speed ratio. The current transferred to the motor by the inverter is approximately equal to the rated current of the motor, ie the motor's power is maximized.
Q: Inverter problem
A: The inverter output 4 ~ 20mA (0 ~ 20mA), the analog signal can be directly connected to the measuring instrument, the daily design, installation, application are so, as long as the selection is correct, there will be no problem.
Q: What is the difference between AC and DC frequency converters?
Advantages and disadvantages: Advantages: inverter air conditioner with variable frequency power supply, inverter compressor, electronic expansion valve and microcomputer technology, the organic combination of air conditioning to further improve the performance, the use of room temperature fluctuations, better comfort, the better Power supply voltage fluctuation is not sensitive, the compressor starts, the general non-stop, cooling capacity in the range of 35% to 117% change, to avoid the frequent open air-conditioning, to extend the life of the compressor, while efficient, Features. Disadvantages: the price is more expensive, compared with ordinary air conditioning, about 1/3 to 1/4 of the price, at the same time, because the inverter air conditioner control system and frequency conversion system is more complex, higher requirements for components, compared to ordinary air conditioning , Inverter air conditioner failure rate is high, and, due to the use of frequency conversion technology, at the same time, will produce harmonic pollution. What is DC inverter air conditioner? DC inverter air conditioner is relative to the AC inverter air conditioner, in fact, its name is not correct, because the DC and no frequency, it is by changing the DC voltage to adjust the compressor speed, thus changing the air conditioning cooling capacity, It can only be said to be a DC variable speed air conditioning, not strictly in the sense of inverter air conditioner.
Q: Who knows how the inverter is calculated?
Quadrupole motor synchronous speed is: 1500 r / min, but the actual motor speed will be more than 14 turn.
Q: Inverter 0.2KW, the motor speed requirements down to 4 turn, the motor pole 4 pole. Can the drive drive the motor?
Can, but this is a test product, the application does not try!
Q: Three sets of batteries (540V) DC power supply U / f inverter.
It is estimated that the battery should be string - and - series connection method, and then rectifier part of the converter (which may also be caused by the switch) is actually a series of diodes in series, positive and negative after the reverse is actually the battery is Negative shorts, resulting in burning, as to burn only one of the group of a few cells, it should be string - and - string and that group, because the parallel to bear it double voltage.