Aluminum Foil Flexible Duct Ventilation air Duct

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
25 litre
Supply Capability:
500000 litre/month
  • OKorder Service Pledge
  • Quality Product
  • Order Online Tracking
  • Timely Delivery
  • OKorder Financial Service
  • Credit Rating
  • Credit Services
  • Credit Purchasing

Add to My Favorites

Follow us:

1.  Aluminum Foil Facing Description

The production technologies and products performance of aluminum foil facing have been up to international advanced level. The aluminum foil facing products are mainly used for HVAC system, refrigerators, building thermal aluminum foil facing insulation and laminated with glass wool and rock wool to increase the insulation function.

• FSK aluminum foil facing is mainly used for duct wrap in HVAC system and other fields, such as vapor barrier etc., and suitable for off-line lamination of glass wool or rock wool. By special processing, the facing will have excellent flame retardant property.

• Heat-sealing aluminum foil facing is used for duct wrap without applying extra adhesive and suitable for online lamination of glass wool and rock wool.

2.Main Features of the Aluminum foil facing

1. Full flexible, high quality factory thermally insulated duct, for all pressure air
conditioning and ventilation system
2. Diameter: 82mm to 457mm
3. Temperature range: -30 degree .C to 80 degree. C
4. Air velocity: Max.30m/sec(5906ft/min)
5. Working pressure: Max.300 mm WG(3000Pa or 12 WG)
6. Fireglass Thickness: 25mm
7. Fireglass Density: 16kg/m3-20kg/m3
8. Standard Length: 10m

 

3.Aluminum Foil Facing Images

 

 Aluminum Foil Flexible Duct Ventilation air Duct

fiberglass heat resistant flexible duct

fiberglass heat resistant flexible duct

fiberglass heat resistant flexible duct

 

4.Aluminum Foil Facing Specification 

TYPICAL PHYSICAL PROPERTIES:

PROPERTIES

UNIT

VALUE

TEST METHOD

Basic weight

gsm

80

ASTM D646

Tensile strength: M. D.

               X. D.

N/25mm

95

50

ASTM C1136

Burst strength

N

25

ASTM D774

Reflectivity of foil surface

%

95

----------

Temp. Resistance

-29°C

+66°C

No change

 keep soft

ASTM C1263

Water vapor permeance

ng/N.s

1.15

ASTM E-96

Water Soak Test

24hrs

No delamination

----------

Width: 1.0m, 1.2m, 1.25 m, 1.30, 1.37m

Length: 200m, 500m, 1000m, 2500m, 2750m, 3300m

Core I.D.: 3"(76mm ±1), 72mm ±1

Based on order, special sizes are also available.

 

5.FAQ

We have organized several common questions for our clientsmay help you sincerely

(1) How about your company?

 A world class manufacturer & supplier of aluminum foil facing and is one of the large-scale professional investment aluminum foil facing bases in China. Annually more than 1000 containers of aluminum foil facing are exported to markets in Europe, America and Japan.

(2)What is the storage condition?

The products should be stored at room temperature and kept from wet and heat source.

It is essential, as with all pressure-sensitive tapes, that the surface to which the tape is applied must be clean, dry, and free of grease and oil.

The user should take test and do trial-application on the above products before coming into application so as to witness and ensure suitability for user’s special purpose and technique. 

(3) How to guarantee the quality of the products?

 We have established the international advanced quality management system,every link from raw material to final product we have strict quality testWe resolutely put an end to unqualified products flowing into the market. At the same time, we will provide necessary follow-up service assurance.

 

Q:What is the difference between the D-LD2000 clamp-type flexible fittings and the KRJ-type clamp-type flexible fittings?
Polystyrene board in the basement wall from the role of waterproof protective layer is to prevent the backfill due to external forces on the destruction of the waterproof layer. That the use of multi-layer board bear two Cao Dutch 丨 sell Zhatai Chun Jun can not. Because the deformation capacity of polystyrene board is relatively large. And the deformation capacity of the multilayer board is small.
Q:What is the effect of concrete pouring on the construction quality?
The use of the trench connection to check the pipe sealing surface is smooth, smooth, no burr. Whether the sealing surface of the sealing ring is scratched, whether the length of the sealing section of the pipe meets the requirements. These three points to ensure that certainly not leaking.
Q:I am sorry to see your answer on Google, can I also pass a copy of my construction and decoration project?
The difference between a flexible pipe and a rigid pipe is that the flexible pipe causes a change in the temperature of the working fluid due to the fluid or medium in the pipe or the temperature of the working environment, resulting in expansion and expansion of the pipe, causing some changes in the pipe itself, Within the scope of the pipeline itself will not cause damage. Such as plastic pipes, metal pipes. Rigid, such as concrete pipes, such as flues, exhaust shafts. Gas and heat is definitely a metal tube.
Q:Will the embedded stove why use stainless steel corrugated hose connection?
The construction of the scaffolding of this project is subject to the requirements of the relevant sections of the latest JGJ130-2011 "Safety Code for Construction Fastener Steel Scaffolding" To design and calculation, the preparation of special safety construction program, after the implementation of the approval. The preparation of the steel pipe should be selected first vertical and horizontal spacing and horizontal bar step, only these are determined in order to calculate the amount of steel pipe.
Q:On the classification of car repair, the best details Thank you Such as sheet metal workers, car circuits, etc. Thank you
first of all, this is a very professional problem, there are many kinds of maintenance shelves, materials are divided into wood, bamboo, steel pipe, etc
Q:How is the flexible casing of the fire pond connected to the tube?
Composite tube: in a tube of the tube with more than two electrode system, each electrode system independently through the electronic flow, to achieve their own functions, this tube is called composite pipe
Q:Maintenance Skills of Leakage of Fire Pipe Clamp Joint
On the use of steel pipe rack (double pole) support, the specific step to be self-checking, if it is 9 meters high, should be taken out of the full frame, the middle of the spine set must be standardized, in fact, we usually do high-level conversion layer beam is very common You share the board as a beam {face - line load}. On the line is not very complicated. Circular arc positioning to be accurate, first to do stereotypes better.
Q:Find a joint electronic M1.5.4 type ECU application system wiring harness and layout Thank you, anxious! The
According to the intrinsic composition of insulation materials can be divided into: inorganic insulation materials and organic insulation materials! Fire rating A is a non-burning point with the insulation effect of materials, materials. Class A non-combustible materials have the characteristics of low density, low thermal conductivity, high pressure capacity, convenient construction, economical and durable. They are widely used in thermal insulation materials and industrial industries such as hot pipes, thermal equipment and other industrial piping equipment and industrial buildings And the civil building envelope structure of the insulation, insulation, sound absorption materials. Because of its good thermal stability, and more for the steel structure of the fire protection coating material. Fire rating B1 level is a flame retardant insulation material, is determined according to the fire resistance of the material, in addition, different parts of the material division is also different! Burning performance: refers to the material and / or products in case of fire burning all the physical and / or chemical changes, that is, the fire reaction characteristics. Fire rating B2 is a combustible insulation material also known as flame retardant materials, mostly organic insulation materials, add the right amount of flame retardants. More common for EPS expansion polystyrene board and XPS extruded polystyrene board, that is, we often say that general board. This material is low in ignition and releases a lot of harmful gases during the combustion process. Fire rating B3 is a flammable insulation material, this is more common as the main material of polystyrene foam insulation material, because this material is easy to burn,
Q:What materials are made of flexible pipes? Why should the mechanical ventilation set the flexible tube? Where should I be located?
Masonry structure construction, the number of pole set which several
Q:How to strengthen the construction management and construction quality control
Combined with national energy Policy, and then according to the design of the various properties of insulation materials, calculated through a complex calculation process is not free to set the thickness.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request