AC Driver 5.5kw 380v 3 Phase Frequency Inverter

Ref Price:
Loading Port:
Qingdao
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
3000 unit/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

5.5kw 400v 3 phase frequency inverter for air compressor  



Introduction of SVF-G7 Series High-performance Vector General-purpose Frequency Inverter

 

1. Voltage class: 380V


2. Range of power: 0.4KW~450KW


3. Stable and reliable Control Mode


(1) VF control: Multiple curve could been chosen, Linear V/F curve, 2.0 times power drop torque V/F curve, custom V/F percentage(can realize manual energy saving control), multipoint VF curve. This apply to the situation that one frequency inverter drives multiple motors, such as fan, water pump, engraving machine, injection molding machine etc.


(2) Open-loop vector control: Steady speed with high precision, wide range of speed governing, as the speed ratio is 1:200 and 180% rated torque could be output in 0.5Hz. Good dynamic performance.

Open-loop vector is suitable for high-Performance universal occasions such as machine tools, centrifuges, cranes and handling equipment, rolling mill and other loads.



(3) Torque control: Fast torque response,<20ms, precision torque: <5%, applied to winding, drawing and other occasions.


Technical Parameter

 

VFD Capacity

Input Voltage (V)

Power Capacity (KVA)

Input Current (A)

Output Current (A)

Adapter Motor(KW)

G3.7/P5.5T4B

3 Phase 380V Range:-15%~20%

5.9

10.5

9/14

3.7/5.5

G5.5/P7.5T4B

8.9

14.6

14/18

5.5/7.5


Model Size

 

VFD Model

W1

H1

W

D

H

Installation Aperture  

Weight (Kg)

SVF-G7-G3.7/P5.5T4B

143

233

155

175

245

Φ5

4

SVF-G7-G5.5/P7.5T4B


 



 

 


Reckoned to be the quality-oriented organization, we ensure that clients are served efficiently most appropriate manner. Clients appreciate our range for their quality and easy availability, besides the reasonable prices. Suggestions of clients are always welcomed and we make changes accordingly if required. We ensure that queries of clients are solved in minimum time-frame with appropriate solutions.



AC Driver 5.5kw 380v 3 Phase Frequency Inverter.jpg.JPG



Trade terms

 

a. Delivery term

We will delivery for you after you done the full payment within 3 to 15 working days.

b. Payment

For small order by air or by express, it is 100% T/T in advance.

For large order by ocean, 30% deposit of the order value should be paid, 70% of the balance payment should be done before delivery.

c. Packing                            

Unless otherwise stated in the offer, the prices include packing in accordance with CHINSC’S customary standard of packing.


AC Driver 5.5kw 380v 3 Phase Frequency Inverter


Applicable fields

Widely used in various fields such as metallurgy, petroleum, chemical industry, textile, power, construction material, coal, pharmacy food, paper making, plastic, printing & dying, lifting, cable making, washing, water supply, heat & ventilation, sewage treatment and son on. In addition the products can also be applicable to draw benches, mixers, extruders, winding machines, compressors, fans, pumps, grinding machines, belt conveyors, hoists and centrifuges.


Welcome your inquiry!

 

 

Looking forward to cooperating with you!


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Laptop power adapter is used to do what
Power and charge the notebook. Equivalent to power, mobile phone charger.
Q:Ordinary 4-pole motor Under the control of the inverter, the higher the speed, the higher the power or the slower the power
The original you are the ordinary motor ah, this ordinary motor can not afford too high frequency. Often at high frequencies or low frequency work will burn the motor. The higher the speed, the current will increase, the lower the speed, the current will be reduced. Its power is not much change. You still with a special frequency control motor it. Frequency conversion motor is a special design, the use of frequency converter for the drive power, the motor and inverter electromechanical integrated frequency control system, so as to achieve low frequency constant torque operation and high frequency constant torque operation. This motor has good speed performance and significant energy saving effect
Q:Siemens g120 inverter torque limit what is the meaning
Torque is a strain, the inverter can not actively control the output torque size, only according to the size of the load demand torque, the output of the corresponding torque.
Q:First reduce the frequency of about one-third of the test, not the case, then appropriate adjustments!
In the inverter in the following 18.5kw inverter will bring their own braking unit for some special occasions, such as the inverter at high speed due to production needs, must be 1 second, or less time to stop, in the stop when the frequency The internal DC bus voltage is too high, the inverter will be reported over-voltage fault, in the positive and negative connected bk-dk connected to a resistor to the inverter discharge, the inverter will not report over-voltage failure
Q:55 瓩 4 pole motor with a frequency of one hour can save much electricity
Such as: 55KW motor full load operation, 1 hour with 55 degrees of power (according to the motor power slightly different changes),
Q:In the case of the inverter, why can not the normal operation after removing the gearbox? The motor is 4 pole.
If there is no load, the demolition of the gearbox is the same can be run.
Q:What is the application of variable frequency speed control?
Frequency conversion is to change the power supply frequency, thus regulating the load, play a lower power consumption, reduce losses, extend the service life of the role. Frequency translation. Frequency conversion technology is the core of the inverter, through the conversion of the power supply frequency to achieve the motor speed regulation of the automatic adjustment of the 50Hz fixed-line frequency to 30-130 Hz change frequency. At the same time, also make the power supply voltage to adapt to the range of 142-270V, to solve the power grid voltage instability caused by electrical work problems. By changing the AC frequency of the way to achieve the AC control technology is called frequency conversion technology.
Q:Oil-free vertical vacuum pump why a little negative pressure inverter on the torque limit
Here is not the inverter can solve the problem, you should first 220V single-phase AC rectifier for the DC (full-wave rectifier plus filter about 310 volts),
Q:Can the laptop 1.3a power adapter be used on a 1.5a device?
No, use a power adapter that is equal to or slightly larger than 1.5a.
Q:Computer frequency changer to do cd frequency changer how points positive and negative
This inverter is 380V of the bar, the capacitor series is to increase the pressure, and then parallel to increase the capacity of the capacity of the capacitor and the inverter is proportional to the power, the greater the capacity of the capacitor capacity requirements are greater.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range