ZX Type self priming centrifugal Stainless steel EX-Proof motor pump

Ref Price:
Loading Port:
Ningbo
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
100 set/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

                            Products Introduction

Product Description


Data:

1.Flow rate (Q)3.2-550m3/h


2.lift head (H) : 20-80m


3.Suction lift: 5-6.5m


4.Rotatory speeed:1450/2900r/min(1800/3600)


5.Suction performance:1.2-3.4 min/5m


6.Shaft power:0.46-126kw


7.Motor power:0.75-132kw


8.Brass or bronze SS304 316 impeller


9.Cast iron SS304 316  pump body


PUMP name:ZX Type self priming centrifugal Stainless steel EX-Proof motor pump

Summarize:

     ZX centrifugal self-priming water pump(diesel water,self-priming pump,water pump,self-priming polluted water pump,pump) are newly developed self-priming centrifugal pumps for clean water or chemicals. The pumps have the compact structure, the high energy-efficiency to operate smoothly and reliably, the long life expectancy. It is just need to check the amount of liquid in the pump for self-priming before starting pump  

1) Detailed instructions

2) Application Area

           The self-priming centrifugal pumps are widely used for applications in the chemical, dye stuffs, petroleum, pharmaceutical, brewery, paper and pulp, metallurgical and mining industries and for oil discharge of oil carrying ships, as well as for water supply and sewage drainage of municipal industrial and emergence services.

3)Industries Served

♦ Construction

♦ Industrial

♦ Municipal

♦ Agricultural

♦ Mining

♦ Dewatering

♦ Industrial Waste

♦ Sewage

♦ Oil Field

♦ Petrochemical

♦ Paper Mills

♦ Processing


4)Parameter

Model
Flow capacity
Head
(m)
Suction
lift(m)
Rotary
speed
(r/min)
Self-priming
performance
min/5m
Power
KW
(m3/h)
L/S
Shaft
power
Motor
power
25ZX3.2-20
3.2
0.9
20
6.5
2900
1.9
0.46
0.75
25ZX3.2-32
3.2
0.9
32
6.5
2900
1.8
0.8
1.1
40ZX6.3-20
6.3
1.8
20
6.5
2900
1.9
0.87
11
40ZX10-40
10
2.8
40
6.5
2900
1.5
2.7
4
50ZX15-12
15
4.2
12
6.5
2900
2.4
1.1
1.5
50ZX18-20
18
5
20
6.5
2900
1.9
1.8
2.2
50ZX12.5-32
12.5
3.5
32
6.5
2900
1.5
2.1
3
50ZX20-30
20
5.6
30
6.5
2900
1.5
2.6
4
50ZX14-35
14
3.9
35
6.5
2900
1.5
2.7
4
50ZX10-40
10
2.8
40
6.5
2900
1.5
2.7
4
50ZX12.5-50
12.5
3.5
50
6.5
2900
1.4
4.3
5.5
50ZX15-60
15
4.2
60
6.5
2900
1.3
6.2
7.5
50ZX20-75
20
5.6
75
6.5
2900
1.3
9.8
11
65ZX30-15
30
8.3
15
6.5
2900
2
1.9
3
65ZX25-32
25
6.9
32
6
2900
1.5
4.4
5.5
80ZX35-13
35
9.7
13
6
2900
3.4
1.9
3
Our Services

 Samply available: 7~10days.
Qty: 1pc, only pump head is provided.
Price: US$100~200
OEM is welcome
OEM expierence: more than 10 years.
Countries: Germany, U.S.A, Spain, Italy, United Kingdom etc
Warranty: the whole pump is guaranteed within 1 year, the pump's spare parts are guranteed for 3 months from the date of delivery.
For more information, please do not hesitate to contact me.

FAQ


The information should be including inquiry as following:
1.Pump's flow rate
2.Pump's Head (Pressure
3.Driven Mode: By electric motor or diesel engine or bare shaft etc
4.Power and rotary speed
5.Suction lift for self priming pump
6.Temperature of liquid if you can provide
Upon the receipt of the pump's parameter, we can send our quotation to you within 24 hours.

Or the condition of pump station would be provided.

♦FAQ:

1.   Q: Can I know more about your products?

       

        A: Pls view our website: www.lanco.cc.

2. Q: What’s your MAQ of this item?

        A: 1~2PCS

3. Q: What is the lead time?

        A: 10~30 days after receiving your payment,depends on pumps.

4. Q: where is your loading port?

        A: Ningbo, China port

5. Q: Are you a manufacturer or trading company

        A: We are a manufacturer specialize in water pump and other pumps more than 20 years.

For more information, please contact me.

Detailed Images








Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Hydraulic pump displacement refers to the pump shaft what?
Displacement of the hydraulic pump refers to the axis of each turn, the volume discharged, called displacement, the unit is ml (ML),
Q:Must the water pump in the tank be all soaked in water?
Of course, if the motor is overheated, it will burn, and the temperature of the water will drop down.
Q:Concrete pump 125 pipe wall thickness
Concrete pump diameter 125mm, pipe wall thickness is generally 4mm, also have 4.25mm, 4.5mm, 4.75mm, need to be in accordance with the rules of transport.
Q:What is a positive displacement pump? He Weizheng displacement?
The principle and structure of displacement pumps are similar to those of hydraulic motors. Positive displacement is the pump outward to provide flow and pressure, that is, conventional pumps. A negative displacement pump is a hydraulic motor that rotates by external pressure and flow
Q:Centrifugal pumps for normal operation, is it reasonable to install valves on their inlet lines?
Submersible pump is best in the water, if dry pumping will cause burns.
Q:If you use an ordinary 15W submersible pump, put it in the tank, if the leakage, the fish will hang it?
Submersible pump even if it really leakage, it will not cause the fish electric shock. The so-called leakage is the submersible pump wire or shell broken, live parts and water contact, the most extreme test is a fire line directly into the fish tank
Q:What is the pump delivery? What's the difference between years and years?
Secondly, the landlord asked the question, although I did not go to the insurance company to practice the operation, but to my four years of learning, as well as internship experience, or can help you analyze, and I hope to help you.Pay is a one-time payment of premium -- all wholesale D sea n
Q:Double floor sewage pump circuit diagram of a small problem
Question 3 when the water level is low, when the 1KA is connected, the pump will run depending on where your SS selector switch is located. Its left and right position, running pump and standby pump definition is different, left position is 1#, running 2# standby, right position is 2# running, 1# standby. Only inIn case the high level switch 2KA is connected, the standby pump may work at the same time.
Q:Know flow and lift how to calculate the pump power?
N=Q.H.g. P / nN - motor power, kWH - pump head, MQ - pump flow, m^3/sG - gravity acceleration g=9.81
Q:Why can't the inlet of centrifugal pump be negative pressure?
However, the centrifugal pump will have its import pressure requirements, which is to prevent cavitation, that is, the fear of the delivery of liquid at low pressure will occur gasification. Centrifugal pump has an important parameter called NPSH, for example relating to the inlet pressure, the pump NPSH, 4 meters, it means that the absolute pressure of imports should be higher than the saturated steam conveying fluid pressure of liquid column is 4 meters high, so, when it is at a temperature of saturated vapor pressure for water transport 2 meters, 4+2=6 meters minimum inlet absolute pressure. Because the absolute pressure is 10 meters water column atmospheric pressure, at this time the entrance negative pressure is 10-6 meters =4 meters water column.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range