Single Stage Horizontal Corrosive Chemical Pump
- Ref Price:
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 10000 set/month
- OKorder Service Pledge
- Quality Product
- Order Online Tracking
- Timely Delivery
- OKorder Financial Service
- Credit Rating
- Credit Services
- Credit Purchasing
1.Specifications of Single Stage Horizontal Corrosive Chemical Pump• Industrial chemical pump
• For corrosion liquid
• Easy maintenance,High efficiency
• OEM order is accepted
• Good quality and service
2.Main features of Single Stage Horizontal Corrosive Chemical Pump
Chlor-alkali industry: lye, electrolyte, refined salt water of ion film caustic soda, chlorine solution, sodium hypochlorite, hydrochloric acid, sulfuric acid.
Iron and steel industry: electroplating, pickling, etc;
Paper-making industry: agents, bleaching liquid, sewage, etc;
3.Specification of Single Stage Horizontal Corrosive Chemical Pump
Model | Capacity | Head | Speed | NPSHr | Efficiency | Power(N)(kW) | Weight | |
Q(m3/h) | H (m) | n(rpm) | r(m) | η (%) | Shaft power | Motor power | w(Kg) | |
IH50-32-125 | 7.5 | 22 | 2900 | 2 | 47 | 0.96 | 2.2 | 34 |
12.5 | 20 | 2 | 60 | 1.13 | ||||
15 | 18.5 | 2.5 | 60 | 1.26 | ||||
IH50-32-125A | 6.7 | 17.5 | 2900 | 2 | 45 | 0.71 | 1.5 | 33 |
11.2 | 16 | 2 | 58 | 0.84 | ||||
13.5 | 14.7 | 2.5 | 58 | 0.93 | ||||
IH50-32-160 | 7.5 | 34.3 | 2900 | 2 | 44 | 1.59 | 3 | 39 |
12.5 | 32 | 2 | 54 | 2.02 | ||||
15 | 29.6 | 2.5 | 56 | 2.16 | ||||
IH50-32-160A | 7 | 30 | 2900 | 2 | 42 | 1.36 | 2.2 | 38 |
11.7 | 28 | 2 | 52 | 1.71 | ||||
14 | 26 | 2.5 | 54 | 1.83 | ||||
IH50-32-160B | 6 | 25.8 | 2900 | 2 | 40 | 1.05 | 1.5 | 37 |
10 | 23 | 2 | 50 | 1.25 | ||||
12 | 21 | 2.5 | 52 | 1.32 | ||||
IH50-32-200 | 7.5 | 52.5 | 2900 | 2 | 38 | 2.82 | 5.5 | 43 |
12.5 | 50 | 2 | 48 | 3.54 | ||||
15 | 48 | 2.5 | 51 | 3.95 | ||||
IH50-32-200A | 7 | 45.3 | 2900 | 2 | 37 | 2.33 | 4 | 42 |
11.7 | 44 | 2 | 46 | 3.05 | ||||
14 | 41.5 | 2.5 | 49.5 | 3.2 | ||||
IH50-32-200B | 6.5 | 39.6 | 2900 | 2 | 36 | 1.95 | 3 | 41 |
10.8 | 37.5 | 2 | 45.5 | 2.42 | ||||
13 | 36 | 2.5 | 48.5 | 2.63 | ||||
IH50-32-250 | 7.5 | 82 | 2900 | 2 | 28.5 | 5.87 | 11 | 75 |
12.5 | 80 | 2 | 38 | 7.16 | ||||
15 | 78.5 | 2.5 | 41 | 7.83 | ||||
IH50-32-250A | 7 | 72 | 2900 | 2 | 28 | 4.9 | 7.5 | 74 |
11.7 | 70 | 2 | 37.5 | 5.95 | ||||
14 | 68.5 | 2.5 | 40 | 6.53 | ||||
IH50-32-250B | 6 | 61.5 | 2900 | 2 | 27.5 | 3.65 | 5.5 | 73 |
10 | 60 | 2 | 36.5 | 4.48 | ||||
12 | 58.5 | 2.5 | 39 | 4.9 |
4.FAQ
① What is your product range?
Centrifugal pump, slurry pump, gravel pump, clean water pump, sewage pump, chemical pump, single stage
pump, double suction pump, industry pump, oil pump, paper pulp pump, mud pump, self-priming pump, pipe
water pump, boiler water pump, etc.
② Are you a manufacturer?
Yes, we have been in manufacturing and marketing industry centrifugal pump over 20 years.
③ What information should I let you know if I want to get a quotation?
Pump capacity, pump head, medium, medium temperature, pump material, quantity, if possible, please also
provide the pump model you are using now, price will be calculated as per the pump model, if not, we will recommend relevant product for reference.
- Q:There are 6 pumps, two indoor fire hydrant pumps, two spray pumps, two outdoor pumps, three units, one master and one spare control cabinet. From the control room to the control cabinet, is there only 3 lines or 9 lines?... How do I get it? Where does the hydrant line come from?
- Spray pump in addition to remote direct Kai, there are modules to start function, that is, on the cabinet to add control module, bus linkage pump, in addition to the pressure switch, directly pumping function, a total of three functions.
- Q:What is the Rhodes pump?
- The ultimate vacuum of roots pump depends on the pump structure and manufacturing accuracy, and also depends on the limit vacuum of the front pump. In order to increase the limit vacuum of the pump, the roots pump can be used in series. The working principle of roots pump is similar to roots blower. As the rotor continues to rotate, the gas is pumped from the intake air to the space between the rotor and the pump housing V0, and then discharged through the exhaust port. Since the V0 space is fully enclosed after inhalation, the gas in the pump cavity does not compress and expand. But when the top of the rotor turns off the edge of the exhaust and the V0 space communicates with the exhaust side, the gas pressure at the exhaust side is higher, and a part of the gas flows back into the space V0, causing a sudden increase in the gas pressure. As the rotor continues to rotate, the gas is expelled from the pump. Roots pump in the pump cavity, there are two "8" shape of the rotor perpendicular to each other on a pair of parallel axis, by a transmission ratio of 1 of a pair of gear belt movements synchronous reverse movement of each other. In the rotor, the rotor and the pump housing between the wall to maintain a certain gap, you can achieve high speed operation.
- Q:Why should the pump be closed when the centrifugal pump is started?
- On the other hand, the water on the pipe of the inlet pipe of the pump is stationary before the pump is opened, such as the sudden acceleration, and the water behind it can not keep up, which will cause the pressure of the inlet to drop suddenly and vaporize the water, and the centrifugal pump will be evacuated. (because of the centrifugal pump is rotating centrifugal force generated by the pump, leaf water and steam driven (gas) quality is very light, according to F= Ma, the centrifugal force is small, the pump can not be water sent).
- Q:Because the water pressure of the booster pump is not enough, it can not work automatically. It can only be operated by hand. It is inconvenient to use.
- If the water pressure is not enough, the pump can not start, then it must be wrong. Because if the water pressure is not enough, the pump should be running automatically. It's just because the water pressure is not enough.
- Q:What is the name of the day pump and ground pump? Specific introduction
- People often say "day pump" actually refers to the boom pump, it also has many other name, such as pump, boom pump, concrete pump, concrete pump truck, these words are "day pump".Ground pump, in fact, refers to the pump drag pump. Therefore, to understand the difference between day pump and ground pump is to understand the difference between the boom pump and the tow pump
- Q:Which nuclear submarines use the shaftless pump technology?
- At present, the submarine has been used in the pump jet technology, the most representative is the United States Virginia class submarine and the Russian North Sea God class submarines.. And shaftless pump is a derivative application of superconducting technology, which is more advanced than pump jet technology..If you want to learn more about shaftless pump technology, you can find relevant papers online.
- Q:What is the function of a submersible pump?Do you have any knowledge about submersible pumps?.
- Submersible pumpThe submersible pump is composed of a control cabinet, submersible cables, water pipes, submersible pumps and submersible motors.Submersible pump main application and scope of applicationIncluding mine rescue, construction, drainage, agricultural irrigation and drainage, industrial water recycling, urban and rural residents cited water supply, and even rescue, disaster relief and so on.Classification of submersible pumpsAs far as media is concerned, submersible pumps can be broadly divided into three categories: clean water submersible pumps, sewage submersible pumps, sea water submersible pumps (corrosive).
- Q:What is the displacement of the pump? Flow? What is the volume efficiency and mechanical efficiency of the pump?
- Mechanical efficiency: the ratio of theoretical torque to actual torque of the pump.
- Q:Why is the submersible pump tripped on an electrical switch?There is no electrical leakage protection, directly connected to the circuit breaker, and when the switch on, the circuit breaker jumpedI checked the line is good, the pump did not break down, is not the water pump?
- Calculate or refer to the water pump nameplate that the normal operating current, according to this data exchange switch.2) with 500V shaking table, measuring the cable, motor insulation is in line with the requirements
- Q:What does "dual purpose" of water pump mean? Please expert advice
- In order to ensure safe and continuous operation, three pumps usually need two units and run one standby.Precautions for using pumps1, if there is any small water pump failure, remember not to work. If the pump shaft packing end wear should be added in time, if you continue to use the water pump will leak. The direct effect of this is the increased energy consumption of the motor, which will damage the impeller.
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Similar products
New products
Hot products
You Might Also Like