Product Description:

Perfect Power Output Section

The HIVERT general MV VFD adopts the power cells connected in series and voltage overlapping method (i.e. Power cells multi-level cascade technology), it can output the perfect PWM sinusoidal waveform (see Figure 2 and Figure 3). It has the following advantages:

1. No need for the additional output filter

2. Directly driving general synchronous or asynchronous motor

3. No de-rating operation on the motor

4. No dV/dt stress on the insulation of motor and cables

5. No torque ripple, extending service life of motors and mechanism

6. No cable length restriction within the acceptable voltage drop.

The general MV VFD has the following protection functions and features:

Overload and over-current

Phase loss and grounding

Over voltage


Current limit

Redundant control power supply

Cell Bypass (optional)

Cabinet door alarm

Phase-Lock function

Synchronous Switching between VFD and Grid system

Soft start of motor

High efficiency >98% (VFD at full-load)

Electrical Isolation by the optic fiber

Built-in PID regulator

RS485 communication with the protocol, Modbus as standard, optional Profibus-DP, Ethernet,etc

Accurate fault records, easy to check fault history

 Compact structure and layout, customized design is available

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:My inverter is the era TVF8000 series, the motor is 15KW6 pole motor, has been used for 3 years.
For your situation about the summary of recommendations: First, check whether the motor overload and whether the leakage exceeded, Second, check and clean the inverter fan, if the room temperature is high, add the external fan to the inverter cooling Third, if none of the above, then please check the inverter module is burned, replace the module Fourth, if the inverter is no problem, then the motor and load the problem, if the motor problems are not resolved, then only re-select the inverter, please select the time to increase the margin
Q:Will the motor suddenly stop when the inverter is suddenly powered down?
Generally in the absence of external brake or brake case, if the power, the motor is in a free stop state, uncontrolled,will gradually slow down to 0
Q:In the case of the inverter, why can not the normal operation after removing the gearbox? The motor is 4 pole.
If there is no load, the demolition of the gearbox is the same can be run.
Q:5.5 kW 4-pole motor with the fastest speed can exceed the rated speed?
Can not be exceeded Although the inverter can run out of the motor rated speed as the motor will soon burn You want your running speed of 2m / s you have to run 5m / s so go eggs do not pull the
Q:Inverter with 2.2KW 6 pole motor. 1 minute 8 times reversing often burn the motor, how to solve. For the 2 pole 4KW motor is the same.
7 seconds more than a change, too often. It is estimated that the inverter will not work. Suggest:
Q:The inverter control power is also the same, the pole is not the same as the motor 6 or 4 pole can be used?
can use. But in the inverter "motor parameters" to be some changes. Such as the number of poles, rated current.
Q:Can the four motors be tuned to 2900 rpm?
You have to look at what is the load, and look at the motor bearing can not bear 2900 turn, if the line, then under normal circumstances are possible. Only to the speed up to the motor rated speed above, the motor output torque is reduced.
Q:Fuji inverter motor set the number of poles will not have any effect?
The number of poles is not the same as the speed is not the same mistake machine can not work or motor coil burned
Q:Motor 2 pole and 4 pole in the inverter with what set to show
Motor parameters, there must be a parameter "motor pole" of the bar.
Q:What is the laptop power adapter? Is it the battery?
Power adapter is inserted in the plug-in power cord connected to the black, rectangular cube that thing, after the power adapter into a notebook acceptable voltage,

1. Manufacturer Overview

Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range