Led Tube Lighting T8 18W 1200mm No Driver AC directly drive
- Loading Port:
- Shanghai
- Payment Terms:
- TT or LC
- Min Order Qty:
- 5 PCS
- Supply Capability:
- 500000 PCS/month
- Option:
- Replaced the power driver by AC circuit
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Item specifice
Products features
1. Patented AC (Alternative current) directly drive.
2. No LED driver design, replace the LED driver by AC chips, more stable and reliable.
3. The invention won the Award of 2014 Geneva International Exhibition of Inventions
4. Prolong the service life of T8 tube to 50,000 hours, it is 2 times as long as traditional driver.
5. High light efficiency. Use high quality SMD chips to ensure the high light efficiency
LED T8 tube 18W | |
Electric parameter | |
Power | 18W |
Voltage | 160~270V AC,50/60Hz |
Power Factor | ≥0.95 |
Operating Temperature | -40℃~50℃,20%~90% H.R. |
Storage Temperature | -40℃~80℃,10%~90% H.R. |
Optical parameter | |
Color Temperature | 5500-6300K |
The LED type | 5630 SMD LED |
Number of LED | 80 PCS |
Angle of LED | 120(Degree) |
Luminous Flux | 1530Lm |
Photosynthetic efficiency | ≥85Lm/W |
Physical parameter | |
Level of Waterproof | IP55 |
Service life | 50000 H |
Electrical categories | ΙClass |
Lamp cover material | High light transmittance glass tube |
Lamp cover color | Milk white |
length | 1200mm |
diameter | 26mm |
Lamp weight | 0.41Kg/0.904lbs |
Mode of package | 30Units/Ctn |
Package measurements | |
Package weight | 15.3KG (33.8lbs) |
LED T8 tube 10W | |
Electric parameter | |
Power | 10W |
Voltage | 160~270V AC,50/60Hz |
Power Factor | ≥0.95 |
Operating Temperature | -40℃~50℃,20%~90% H.R. |
Storage Temperature | -40℃~80℃,10%~90% H.R. |
Optical parameter | |
Color Temperature | 5500-6300K |
The LED type | 5630 SMD LED |
Number of LED | 75 PCS |
Angle of LED | 120(Degree) |
Luminous Flux | 850Lm |
Photosynthetic efficiency | ≥85Lm/W |
Physical parameter | |
Level of Waterproof | IP55 |
Service life | 50000 H |
Electrical categories | ΙClass |
Lamp cover material | High light transmittance glass tube |
Lamp cover color | Milk white |
Length | 1200mm |
diameter | 26mm |
Lamp weight | 0.41Kg/0.904lbs |
Mode of package | 30Units/Ctn |
Package measurements | |
Package weight | 8KG (17.7lbs) |
Revolutionary no driver LED, Alternative directly drive, high efficiency and stability
Pioneered the AC directly drive LED solution, replaced the traditional LED driver by TF-11 and G13 chips. The patented technology won the award of 2014 Geneva International Exhibition of Inventions. The reliability and service life of LED are improved enormously by AC directly drive solution. The service life of AC drive solution surpasses 100,000 hours.
High grade luminous source
Professional encapsulated SMD 5730 with high quality LED chips ensures the LED resource obtaining excellent protection of optical attenuation and the heat conduction ratio. Reduced the optical attention rate to the minimum value as 3% per year.
Triple heat dissipation, Super long service life.
- Q:What's the difference between a single input and a double-end input?
- Like our products, single side used on special occasions, be flat installation place, double side is directly used in the traditional ordinary lamp, so change the LED fluorescent lamp is very convenient.
- Q:The ambient humidity of the LED daylight lamp is in the range
- If you're in a particular high humidity environment, don't use an ordinary led fluorescent lamp, considering the safety of an led lighting device that USES waterproof dust
- Q:What causes the red light on both ends
- On both ends of the fluorescent lamp with a filament, when using the filament with a long time because of the heat for a long time makes its internal metal tungsten evaporates and attached to the fluorescent lamp on the wall of darkened, and so you turn on the light because the light on the wall that had led to that piece of dark red.
- Q:Can a fluorescent tube be used in series?
- The second floor says: "theoretically can light up". Can you say the theory? In theory, I think, it's not bright.
- Q:Why is it that when my electric car is charged, the light bulb is burning in the house, and the incandescent lamp is fine, and the other appliances are normal
- It is possible that the high frequency pulse of the charger inside the charger is flowing into the power grid, causing the fluorescent lamp ballast to work and burn down. Electric car charger belongs to the circuit structure of the switching power supply, and the internal vibration circuit is used to produce high frequency signal to drive the transformer. Please use the TV interference method to test electrical good or bad. Put the charger in the TV next to blunt electricity. Television will have interference image will solve the problem that there is something wrong with the charger repair and replacement..
- Q:What are the types of leds?
- The T5 is powered by a small lamp and no power supply. The component is the power supply of LED lamp tube, buy return is a light tube + a set of power supply, the installation time should use the old lamp tube support, also install the power supply
- Q:In several production workshops of my unit, we will replace a batch of philips T5 fluorescent fluorescent lamps with LED fluorescent lamps. However, it took more than two years to get rid of the old lamp, and it was neither green nor economical, so consult the high man.
- The fluorescent lamp doesn't seem to have a dedicated recycling system. Go to secondhand market transfer, after appearance is refurbished, again can use Led fluorescent lights are needed
- Q:The two ballast that originally was electric inductance towed three ordinary fluorescent lamps, now changed to LED fluorescent lamp tube, have influence?
- The impact is certain, and it wastes electricity. It is expected to waste about 12W of power, and if it is powered by a capacitor, it will also greatly affect the brightness.
- Q:Electronic ballast tube lamp change led lamp tube how to change circuit how to do
- Usually direct 220V, in the package of the lamp tube has the wiring diagram, does not use the original ballast, the nature is different
- Q:Do the fluorescent tubes save electricity for 10 minutes, or do they save electricity in a split second?
- Although the data is missing, the electric current of the opening is larger and the power consumption is no more than 10 minutes
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Led Tube Lighting T8 18W 1200mm No Driver AC directly drive
- Loading Port:
- Shanghai
- Payment Terms:
- TT or LC
- Min Order Qty:
- 5 PCS
- Supply Capability:
- 500000 PCS/month
- Option:
- Replaced the power driver by AC circuit
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products
Related keywords