• LED Tube Lamp No Flicking SMD2835 T8 18W 1200mm System 1
  • LED Tube Lamp No Flicking SMD2835 T8 18W 1200mm System 2
LED Tube Lamp No Flicking SMD2835 T8 18W 1200mm

LED Tube Lamp No Flicking SMD2835 T8 18W 1200mm

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 pc
Supply Capability:
200 pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Item specifice

Color Temperature:
Warm White
Lamp luminous flux(lm):
800
Body material:
Aluminum
Power(W):
18
Certification:
BV,C-tick,CCC,CE,CQC,EMC,Energy Star,ETL,FCC,FDA,GOST,GS,LVD,PSE,REACH,RoHS,SAA,SASO,UL,VDE
Working Temperature(℃):
0
PF:
>0.9
Input voltage(V):
100-277
CRI (Ra>):
>80
Warranty:
two years

NO flicking smd2835 T8 18W 1200mm led tube lamp

 
1) Product Description
 LED Tube lighting

DescriptionT8/T5 Led Tube
CertificationETL DLC TUV SAA C-tick CE RoHs
Led ModelSMD2835 / 3014
Lumen Output>100 Lm/w
Warranty3 years
Input Voltage100-240V / 100V-277V
Power Factor>0.9
LED color index (CRI)Ra > 80
Color Temperature2700K - 6500K
Beam Angles120degree
MaterialAluminum & PC Cover
Working Temperature-30°C ~ 60°C
Average lifetime50,000 hours

 LED Tube Lamp No Flicking SMD2835 T8 18W 1200mm

2) ♠ Product Feature
- DLC ETL TUV SAA BV C-tick CE RoHS 
- SMD2835 / 3014 led chip, 100Lm/W CRI>80
- Constant current and Isolated power supply  PF>0.9
- Directly installing, no modification, No need rewire ,
- Running without Ballast and starter.
- Thickened 0.9mm aluminum radiator for heat dissipation
- Energy saving up to 80% high intensity
- Inner power efficiency more than 87%
- Heat protection systerm,can work under unstable voltage
 
3) ♠ Applications
1,Widely used in products such as drinkery,hotel,hall,chamber,
    villa and other slap-up locations to illuminate and decorate.
2,Store relevation,showcase,restaurant and other indoor decorations and lighting,
    relevation hall,arthallmuseum,office,reading roomand locallighting;groggery
 
4) ♠ Specifications of Led T8 Tube
LED Tube lighting

Model No.WattLengthLumensLED ModelLED QtyWarrantyVoltage
LY-T8L600-6W9W600mm/2FT900LM±10%SMD2835/301480pcs3 Years100-240V
LY-T8L600-9W12W600mm/2FT1200LM±10%SMD2835/3014144pcs3 Years100-240V
LY-T8L900-13W13W900mm/3FT1300LM±10%SMD2835/3014120pcs3 Years100-240V
LY-T8L1200-18W18W1200mm/4FT1600LM±10%SMD2835/3014160pcs3 Years100-240V
LY-T8L1200-20W20W1200mm/4FT1800LM±10%SMD2835/3014192pcs3 Years100-240V
LY-T8L1200-22W22W1200mm/4FT2200LM±10%SMD2835/3014216pcs3 Years100-240V
LY-T8L1500-22W22W1500mm/5FT2200LM±10%SMD2835/3014220pcs3 Years100-240V
LY-T8L1500-24W24W1500mm/5FT2400LM±10%SMD2835/3014240pcs3 Years100-240V
LY-T8L1800-26W26W1800mm/6FT2600LM±10%SMD2835/3014256pcs3 Years100-240V
LY-T8L2400-36W36W2400mm/8FT3600LM±10%SMD2835/3014356pcs3 Years100-240V
LY-T8L2400-44W44W2400mm/8FT4400LM±10%SMD2835/3014432pcs3 Years100-240V
         NoteCertificate: ETL DLC TUV SAA C-tick CE RoHs
Power Factor(PF)>0.9 CRI>80
CCT.:2700-3000K/ 4000-4500k/ 6000-6500K
Materials: AL+ Milky PC / Clear PC/ Stripe PC
Base: G13 Bin-pin / Fa8/ Rotating/ Single Pin


5) Packaging & Shipping
 ♠ Packing Item

     Length(mm)Gift Box SizeCarton SizeQty/CartonN.W.G.W./Carton
( L*W*H )mm(L*W*H) mm( Pcs )(g)(KGS)
LY-T8L600-9W/12W32*32*666680*340*1805027014.1
LY-T8L900-13W32*32*972985*340*1805037019.2
LY-T8L1200-18W/20W/22W32*32*12761290*275*1804047020.8
LY-T8L1500-22W/24W32*32*15761590*210*1803061019.2
LY-T8L1800-26W32*32*18411855*210*1803070021.9
LY-T8L2400-36W/44W32*32*12252465*180*1801691023.6

 
 
 6) ♠ Shipping options
1, By express: Such as DHL,UPS, TNT, FEDEX etc. The dispatch time is about 3-7 working days.
2, We will search for an economical shipping company to transport the goods safely.
3, Air Freight: When you order more than 100kg which will be more economical than express.
4, Agent designated by client: Please tell us the contact details of your shipping agent/forwarder
 
 
 
  1.ISO9001 Professional LED light Manufacturer
   2.High technology equipment,Standout R&D team, Skillfull workers,8 production lines.
   3.Monthly Production Capacity over 80,000pcs.
   4.Remarkable QC system,Make sure the Quality and stability.
   5.UL,ETL,DLC,SAA,TUV,CE,ROHS Certificates.
   6.Main market now: USA,Canada,Germany,U.K. & Australia.

8) FAQ
♠Why choose LED ?       
♥ Our service
1.OEM & ODM are offered.
2.30more R&D engineer.All your questions will be replied in 24 hours.
3.Distributorship is offered for your unique design and some our currect models.
4.Protection of your sales area,Ideas of design and all your private information.
5.If the oder more than 500pcs,we will return back the payment of samples.
 
9) ♥ Reliability
1.As long as 72h aging test with automatic switching before each shipment.
2.100% vibratility test will make sure the fastness of the assembling.
3.100% resist voltage test of AC85-305v makes sure those tubes compatible for both 120v and  277v.
4.More than 95% lumen maintenance based on the 6000h LM-80-08 test
5.-40°C to 50°C(-40°F to 122°F) extreme environment compliant.
 
10) ♥ Trade Terms »  »  »
Payment: T/T , 30% deposits before production, 70% balance to be paid before delivery.
Production lead time for 100~500pcs: 7days, 500~1000pcs:10days
Sample can be delivered in 3 days
Discounts are offered based on order quantities
 

 

Q:The T8 nominal 36W standard daylight bulb is only 18W
Do you know your own design is what reason. Now in the market is almost not not qualified fluorescent lamp, fluorescent lamps (CFL) so I said is rubbish products. By doing a lot of LED torch is take waste products such as the contrast of the object, in fact only take the LED of the measured power and comparison of the nominal power of the fluorescent lamp to do, just can have what 18 w instead of 40 w theory and practice,
Q:Put on the new light bulb, why the lamp still not bright
For the electronic ballast, if no response after the power supply the tubes, should first check whether the fuse of the ballast burned, if it is a filament is red, estimation is ballast resonant capacitance breakdown.
Q:The lighting is replaced by LED lights and circuit problems
No, you're going into a ballast, one is out. The picture you gave is only part of it. When you disconnect the ballast, connect the same color. The red one is the wire, the current of the ballast. After disconnecting, it should be a connection between the red wire and two broken wires. You should shoot the right wire again. The situation in my home was to tear down the ballast and the two red lines were connected to the red line. The green earth line connects to the blue line. You have to capture the essence of the problem, and you have to see the current flowing. The current must be in and out of the ballast. When you disconnect the ballast, you should connect the broken one to the other. This will make the current pass.
Q:20wled bulbs are more energy-efficient than 20w fluorescent bulbs
Led fluorescent lamp is twice as common fluorescent lamp, luminous efficiency is 10 w led fluorescent lamp brightness is equivalent to 20 w common fluorescent lamp brightness, what's more, the led fluorescent lamp light Angle of 120 degrees, ordinary fluorescent lamp light Angle is 360 degrees, so the led fluorescent lamp to use more efficient, and common fluorescent lamp ballasts, it also consumes, and led fluorescent lamp does not need. So led fluorescent lamp is very energy-saving, normally can guarantee 3 years.
Q:How much energy does normal lamp tube compare with LED light tube?
When installed the LED fluorescent lamp is very simple, the original of the fluorescent lamp to remove the LED fluorescent lamp, ballast and electric fluorescent starter, let 220 v ac mains on both ends of the LED fluorescent lamp directly. LED fluorescent lights are up to 80 percent of the electricity, and more than 10 times that of a normal lamp.
Q:What kind of lamp tube is the 2G11 lamp of LED fluorescent lamp
It's a lamp holder, which is different from T8 T10. The spacing of the pins is different. Look at figure 2G11. If you don't understand, you can add me Q9, 5, 3, 4, 7, 2, 5, 3, 2
Q:Is there a greater value in switching from a normal daylight lamp to an LED energy-saving lamp?
I can give you a detailed example of your problem: LED fluorescent lamp tube 6w can replace the normal daylight lamp tube 20w, 9w can replace 30w, 12w can replace 40w, 15W replace 45W, 18w can replace 60w, save more than 70% electricity; LED life can theoretically reach 5-100,000 hours, nearly 10 years. Q: how much electricity do you need a year if your company owns 10,000 40W, regular daylight bulbs (plus a rectifier, for example, 46-49 watts)? A: common light bulb: 365 days * 15 hours * 46w * 10,000 lamp tube / 1000W (1 hour) * charge 1 yuan = 2518500 yuan. LED bulbs: 365 days * 15 hours * 12W * 10,000 tubes / 1000W (1 hour) * charge 1 yuan/degree = 657,000 yuan. On the data, the cost can be recouped within a year, saving as much as $3 million in electricity bills within three years.
Q:Is it healthy to hang a towel with a bad fluorescent lamp
Mercury vapor reaches 0.04 to 3 mg, which causes chronic toxicity in two to three months. An increase of 1.2 to 8.5 mg can cause acute mercury poisoning, and if it reaches 20 mg, it leads to death.
Q:I hope my answer will help you
It is recommended to remove the silver and then remove the lamp.
Q:Fluorescent lamp fire line zero connection
The fire line is different from the zero line Both the wire and the zero line are charged lines, and if the two phase power is connected to the electrical appliance, the current flows through the wires General feeling of fire electricity, because if people (including some indirect contact with) the contact wire, part of the electric current is passed from the body, like a ShuiGuanZi, originally from the middle points of a faucet. The zero line is not charged because the other side of the power supply (zero) is connected to the ground, and when we reach the zero line on the ground, because there is no difference, there is no current. So there's a zero line of uncharged feeling. The zero line and the fire line are originally generated by the power supply, and the current direction of the current is the one that goes through the external device and comes in from the other end, forming a circuit. The difference between the zero and the wire is one of the two terminals of the power supply So the fluorescent lamp will not be bright!

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products