Item specifice:

Color Temperature: Pure White LED type: SMD5630 Size: 600mm*26mm
Lamp luminous flux(lm): 850 Type: LED Tube Body material: Glass
Working lifetime(Hour): 50000 Power(W): 10W Certification: CCC,CQC
Working Temperature(℃): -40~50 PF: >0.95 Input voltage(V): 100-277
CRI (Ra>): >90 Warranty: two years IP Rating: IP55

Product Description:

Products features


   1. Aaward-winning technology of 2014 Geneva International Exhibition of Inventions

2. Patented AC (Alternative current) directly drive.

3. No LED driver design, replace the LED driver by AC chips, more stable and reliable.

4.   Prolong the service life of T8 tube to 50,000 hours, it is 2 times as long as traditional driver.

5.  High light efficiency. Use high quality SMD chips to ensure the high light efficiency

6.  Low lumens depreciation. Less than 3% per year. The users needn’t to replace the tube during 4-8 years.


High purity glass tube

Good heat dissipation

Patented AC driving solution

Super long service-life


Perfect AC directly drive solution which won the won the 2014 Geneva International Exhibition of Inventions. 

As the global leader in LED driving technology.  


AC Chips replace the traditional LED driver. 

The service life of AC chips more than 100,000 hoursso service life of the whole tube more than 50,000 hours. 

The ueser needn't replace the tube in 4-8 years. 

LED T8 tube 10W

Electric parameter




160270V AC50/60Hz

Power Factor


Operating Temperature

-40~50℃,20%~90% H.R.

Storage Temperature

-40~80℃,10%~90% H.R.

      Optical parameter

Color Temperature


The LED type

5730 SMD LED

Number of LED

75 PCS

Angle of LED


Luminous Flux


Photosynthetic efficiency


Physical parameter

Level of Waterproof


Service life

50000 H

Electrical categories


Lamp cover material

High light transmittance glass tube

Lamp cover color

Milk white





Lamp weight


Mode of package


Package measurements


Package weight

8KG 17.7lbs


Revolutionary no driver LED, Alternative directly drive, high efficiency and stability


Pioneered the AC directly drive LED solution, replaced the traditional LED driver by TF-11 and G13 chips. The patented technology won the award of 2014 Geneva International Exhibition of Inventions. The reliability and service life of LED are improved enormously by AC directly drive solution. The service life of AC drive solution surpasses 100,000 hours.     


High grade luminous source

Professional encapsulated SMD 5730 with high quality LED chips ensures the LED resource obtaining excellent protection of optical attenuation and the heat conduction ratio. Reduced the optical attention rate to the minimum value as 3% per year.

Triple heat dissipation, Super long service life.


Utilizing high thermal conductivity aluminum plate, high purity glass tube and no LED driver consumption, the triple heat dissipation design ensures that chips can conducting the heat rapidly. Our LED tubes are driven directly by Alternative current without delay start, unaffected by electric fluctuation. The service life of T8 tube is more than 50,000 hours and it’s 2 times than that of traditional LED driver tube. So users needn’t replace the tube in 4-8 years.   


Uniform illuminance, Comfortable visual sense


The LED tubes use high luminous transmittance glass tube to reach high transmissivity, the transmissivity over 99%.

The surface of tube was frosted without light spot. The light is soft and pure spectrum, high CRI ( color rendering index )without ultraviolet ray, infrared radiation, ensure users a comfortable visual sense.

 Our tube process soft light, pure spectrum, high CRI ( color rendering index ) without ultraviolet ray, infrared radiation to ensure users a comfortable visual sense.



Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:The notice of LED daylight lamp tube
The service life of the LED fluorescent tube, LED fluorescent lamp power saving more than 80%, life expectancy of more than 10 times of ordinary lamp, is almost free maintenance, often there is no want to change the lamp, ballast, the problem of electric fluorescent starter, about half a year down can switch back to the cost of cost savings. Green environmental protection of semiconductor lighting, the light is downy, spectrum pure, is good for eyesight protection of workers and healthy body, the 6000 k cold light source, give a person the feeling of cool and refreshing on the vision, help to concentrate, improve efficiency.
Q:Feasibility analysis report of LED lamps
With the advent of ultra bright white leds, applications in lighting have become possible. According to the international authorities, the 21st century will enter the era of new lighting, which is represented by leds, and is called a fourth generation new light source. At present, the lighting consumption accounts for about 20% of the whole power consumption, reduce lighting electricity is an important way to save energy, in order to achieve the goal of the industry have developed many kinds of energy-efficient lighting apparatus, and achieved certain results. However, the requirement of "green lighting" is not enough, and it is imperative to develop and apply a new source of efficiency, reliability, safety and durability. LED with its inherent superiority is attracting the world's attention. According to the forecast the U.S. department of energy (doe), around 2010, the United States will have 55% of incandescent lamp and fluorescent lamp is replaced by LED, power saving value of up to 35 billion dollars a year, may become a $50 billion industry. Japan suggested that leds would replace traditional incandescent lamps in 2006. LED development history has for decades, but the application in the field of lighting and new technology, but with the rapid development of LED technology, gradually improve the luminous efficiency, LED the market will be more widely used, especially in the rising again under the background of global energy shortage, the LED in lighting market prospect is more highly attention around the world, is considered by the industry in the next 10 years to become the most promising markets, as well as the biggest markets will be replace incandescent lamp, the greatest potential for tungsten filament lamp and fluorescent lamp.
Q:Fluorescent lamp fire line zero connection
The fire line is different from the zero line Both the wire and the zero line are charged lines, and if the two phase power is connected to the electrical appliance, the current flows through the wires General feeling of fire electricity, because if people (including some indirect contact with) the contact wire, part of the electric current is passed from the body, like a ShuiGuanZi, originally from the middle points of a faucet. The zero line is not charged because the other side of the power supply (zero) is connected to the ground, and when we reach the zero line on the ground, because there is no difference, there is no current. So there's a zero line of uncharged feeling. The zero line and the fire line are originally generated by the power supply, and the current direction of the current is the one that goes through the external device and comes in from the other end, forming a circuit. The difference between the zero and the wire is one of the two terminals of the power supply So the fluorescent lamp will not be bright!
Q:How many lumens is the T5 bulb of 18W
If the screw lamp, generally in the luminous flux of 50-60 lm/W, and haven't consider it droop, even if Edison lamp just pack up and give a person feel very bright, but as long as a long time can tell what separates!
Q:The LED light bulb is more efficient than the daylight lamp
In the same power, it's more efficient.I hope my answer is useful to you.
Q:I hope my answer will help you
Rotate it, or you can move the tube to the right and try it.I hope my answer will help you.
Q:Daylight lamp tube is broken, does not clean can be bad? In the office
What is destroyed can bring a bad feeling and affect the person's mind
Q:I have LED lights on fluorescent lamp tubes, and I have tested five times a dc
No good. 220v is a valid value. The maximum value is 310v, and it burns instantly.I hope my answer will help you.
Q:Now there is no led lighting, just like the fluorescent light bulb, which is universal
Yes, it is installed directly on the original lampstand, remove the regenerator.
Q:How to connect the power supply when the LED lamp is energized?
The power supply is not positive and negative, and the power supply can only work under the dc environment. Normally bought LED lamp tube has built-in power, can be used directly in the lamp holder, but should be careful to remove the regenerator, short connect ballast. You can also go to LED918 for me.

1. Manufacturer Overview

Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range