Product Description:

  • The technical parameter of type XS pump:

    Pump outlet diameter: Dn:  80~800mm

    Capacity: Q:  22~11600m³/h

    Head : H:  7~200mm
    Temperature :T:   -20°C~105°C(Type XS)
                                 -60°C~200°C(Type XS—R)
    Solid parameter:     ≤80mg/L
    Permissible pressure ≤2.5Mpa  (Type Xs)
                                 ≤4Mpa      (Type XS—R)

    Technical Advantage:

    1.       Type XS pumps work stably with less noise and vibration and can work at a lifting speed due to short support at both sides, thus they can be widely used.

    2.       The pipelines arrangement of type XS pump looks simple and beautiful due to inlet and outlet at a same center line.

    3.       The same rotor of type XS pumps can be operated at reverse direction to avoid damage to the pumps water hammer.

    4.       Unique design of type XS pumps working at high temperature using middle support to fasten the pump casing and using cooling seals oil lubrication bearing then pump suitable for working at 200℃ especially for supplying heated water to pipe net system.

    5.       Type XS pump casting parts can be vertically or horizontally mounted according to different working condition, with mechanical seals or packing seals.

    6.       Type XS pumps look beautiful with visible lines adopting industrially designing.

    If you have any special requirement, please contact us without hesitation.No file download!

















Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What are the ways of hydraulic pumps?
There are several ways:Direct flow mode, such as external gear pump;Port plate, such as vane pump, axial piston pump, etc.;
Q:How to maintain and repair the booster pump of pipeline pump?
Installation and use1. use rubber washer and bolt to connect the pump flange at both ends and the pipe flange. In order to use and maintenance convenience, in the pump inlet and outlet pipelines should be installed with a regulating valve.2. open the inlet control valve, so that water into the pump, in order to keep the cavity filled with liquid (otherwise it will damage the seal), close the outlet valve.3. turn on the power and make sure the correct turn.4. make sure the pump starts and runs after turning.5. adjust the opening of the outlet valve so that the pump runs near the design point, depending on the rated flow and lift of the pump. [for this reason, it is better to place a pressure gauge near the outlet flange). Note: this pump is strictly prohibited to run without water, so as not to damage the seal.
Q:What is a vacuum pump for?
You are not confused by different names. It is mainly used in folding machines, paper cutting machines and water treatment aeration
Q:The distance from the pump button to the ground
After confirming that the fire pump has started running, issue a command signal to the hydrant button to light the green answer light.
Q:What are the functions of a disposable infusion pump?
This is a very professional question, ha!I only know disposable infusion pumpsAttached: intelligent medical infusion pump and its application
Q:Why does the centrifugal pump start with a closed valve and the axial pump starts with an opening valve?
Centrifugal pumps require a vacuum to produce negative pressure, which allows atmospheric pressure to lift the water surfaceAxial flow pump impeller is thrust on water
Q:What's the difference between non negative pressure and variable frequency water pump?
Re pressure to a given pressure pressure zone water supply, than frequency conversion water pump energy savingFrom a health perspective, a water tank variable frequency water pump, water tank and the atmosphere, easy occurrence of water pollution two, no negative pressure equipment without negative pressure tank and pump and valve fittings etc., no water tank, the whole process of water supply of water is completed in a closed system, with air contact to avoid two pollution problems water supply.From the management point of view, no negative pressure is fully automatic intelligent operation, reduce management costs, no water tank, reducing the trouble of tank cleaning. No negative pressure is the upgrading of variable frequency water pump products
Q:What is the minimum continuous flow of a pump?
Quality solutionsMinimum flow of pump, minimum continuous flow of pumpIn order to ensure the proper use of the pump and the normal operation of the pump manufacturer will indicate the minimum pump in the sample of the continuous operation flow, the correct selection or use to warn or instruct users. According to the provisions of the API standard, the minimum continuous flow into the minimum continuous stable flow and continuous flow. Most small thermal limit(1) the minimum continuous stable flow.API standard specifies the minimum continuous stable flow refers to the vibration limit does not exceed the standard set by the pump can work normally. The minimum flow pump at small flow rate, there will be noise and vibration increase, API of this provision is to ensure that the service life of the pump, avoid due to improper operation of the pump caused by the adverse effects.
Q:Constant pressure pump working principle
15MPa. 20MPa means that if you enter the 20MPa, the variable mechanism will work, and the flow at this time automatically matches the load. 20MPa used to supply the fuel by maximum displacement.
Q:How should the water pump be installed?
(4) before installation, make sure all pipes connected with the pump should be clean, and no solid foreign bodies which may cause damage to the pump shall be allowed.(5) apply the blind flange or other things to the suction, exhaust or open pump to ensure that no sundries enter the pump cavity during the installation.(6) check whether the pump random data is complete and complete; whether the pump surface has obvious damage. Only with complete data, no obvious damage to the pump, you can continue to install.(7) the installation of centrifugal pump with the coupling of the hand when turning slowly rotating coupling or pulley, observe the pump rotation are stable, flexible and adjustable, the rotor parts have no jamming, the pump has no debris crash, bearing the operation is normal, with elastic suitability.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range