• High quality UL T8 LED tube with 3 year warranty System 1
  • High quality UL T8 LED tube with 3 year warranty System 2
  • High quality UL T8 LED tube with 3 year warranty System 3
  • High quality UL T8 LED tube with 3 year warranty System 4
High quality UL T8 LED tube with 3 year warranty

High quality UL T8 LED tube with 3 year warranty

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
150000 pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

High quality UL T8 LED tube with 3 year warranty


High quality UL T8 LED Tube with 3 year warranty Features:

Ø  2/3 Aluminum body and 1/3 94-V0 level optical-grade PC cover

Ø  No delay or warm up time, no mercury,no maintenance.

Ø  Low power consumption and can save energy up to 75%

Ø  The length-2ft,4ft,5ft are available

Ø  RoHs,UL certification are approval.

Ø  Directly compatible with magnetic ballast fixture,3 years warranty


High quality UL T8 LED Tube with 3 year warranty specification:

Item

T8-UL09

T8-UL18

T8-UL22

Dimension

600mm

1200mm

1500mm

Power

9±1w

18±1w

22±1w

LED Qty

54 SM2835

100 SMD2835

110 SMD2835

Lumen(lm)

1000±50

1800±100

2200±100

CCT

3000-3500K warm white  |  4000-4500K nature white  | 5500-6500K daylight

CRI

80Ra

PF

>0.92

Beam angle

240°


Installation Guide for High quality UL T8 LED Tube with 3 year warranty

1. Turn power off by disconnecting the supply voltage.

2. Remove current fluorescent lamps and dispose of them properly based on local regulations

3. Find and remove existing fluorescent starter

4. Insert LED T8 starter provided into existing fluorescent starter location

5. Installer should apply caution label provided to luminaire to state that luminaire has been modified and operates only LED lamps

6. Check fluorescent socket for damage. If damaged replace with one of the exact configuration and rating.Insert T8 LED lamp

7. Turn power back on and check for proper operation



Q:How do the long daylight bulbs change
Two kinds: the lamp tube moves to the left or right, the spring quantity is compressed, the two feet of the other end of the lamp pull out and pull out. Install instead.
Q:How to detect the good and bad of the fluorescent lamp
Normally, the filament on both ends is not broken is good.
Q:What causes the red light on both ends
There are two kinds of red light on both ends of the fluorescent tube: 1, if it is the use of long tube, gradually from both ends of black, red in the end, there is a gradual process, is basically a lamp aging, filament will burn out the precursor, exchange tubes can troubleshooting; The lamp tube USES all the time normal, occurrence afore-mentioned phenomenon suddenly, that most is the rectifier is caused by failure, change rectifier can.
Q:Can a fluorescent tube be used in series?
Because 20 watts bulb needs about 450 v high voltage to the breakdown, 40 tile tubes need about 550 volts can be breakdown. Usually ballasts provide high voltage is slightly more than, but not more than a lot.
Q:How does the lamp line connect
The one that used to be in the early part of the world, which requires the regenerator to cooperate with the light, is an inductance ballast, and the fluorescent tube now needs to glow without the regenerator. The ballast that doesn't need a regenerator is an electronic ballast. Ask to sell tubes of the owner, they all know and electronic ballast inductance ballasts, now basically eliminated inductance ballasts, everybody understand the electronic ballast is enough. If it is an old lamp, it will meet the inductive ballast. The lamp tube has two feet on each side, and the left and right sides are four feet
Q:Is there any LED fluorescent lamp that can be used for more than five years?
LED lights are used for start-up time, and if it is open tomorrow for four to five hours it should take five years, but there will be light decay.
Q:20wled bulbs are more energy-efficient than 20w fluorescent bulbs
LED power, which USES electricity at the same brightness, is 80 per cent of other appliances.
Q:What is the minimum starting voltage for the fluorescent tube?
I use the 20 watt fluorescent lamp to measure the lowest maintenance of the tube and the voltage is 98V volts.
Q:What is the conversion between the number of leds and the number of tiles?
In this case, we'll talk about energy efficiency.I hope my answer is useful to you.
Q:Fluorescent lamp double lamp tube wiring method
Leds that do not normally require special orders are mostly built with built-in power, which is directly available. Most can only need to remove the starter on the traditional stent line (is a cylinder bracket highlighted below) mount tubes can be used, if not yet so could you use the stent is a relatively new "electronic" will be a little trouble need you open the stents to get inside the ballast also take off to the inside of the line directly connected to the utility, LED bulb is directly at the mains. Of course, if you understand the circuit and you're not afraid of trouble, it's advisable to remove the "regenerator", because the "ballast" is a power drain.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords