High Alumina 0-1mm 1-3mm 3-5mm Calcined Bauxite Granular for Road Making

Ref Price:
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
111 m.t
Supply Capability:
11111111 m.t/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

 

1.Structure of Calcined Bauxite Description

Bauxite (aluminous soil; Bauxite) is also called the alumina or bauxite, main ingredients are alumina, hydrated alumina containing impurities, is an earthy mineral. White or gray, brown and yellow or light red by iron.  From 4 to 3.9 g/cm3 density, hardness, 1 ~ 3 is not transparent, very brittle.  Very difficult to melt.  Insoluble in water,  soluble in sulfuric acid, sodium hydroxide solution. Mainly used for aluminium, refractory material. 

 

2.Main Features of the Calcined Bauxite

Calcined bauxite is one of the principal ore of aluminum. Calcined bauxite contains hydrous aluminum oxides and aluminum

hydroxides, formed through the laterization of aluminous rocks in tropical and subtropical areas .Calcined bauxite is obtained by calcining (heating)superior grade bauxite at high temperature (from 85OC to 1600C) .This removes moisture there.By increasing the alumina content,compared to an alumina content of about 57%to 58% in raw bauxite, calcined bauxite has an alumina content of 84%to88%.The heating is carried out in rotary kilns. 

3.Main usage of the Calcined Bauxite

(1) aluminium industry. Used in national defense, aerospace, automotive, electronics, chemical industry, daily necessities, etc. 
(2) precision casting. Alumina clinker made after the mould precision casting processed into fine powder. Used in military industry, aerospace, communications, instrumentation, machinery and medical equipment department. 
(3) is used for refractory products. High bauxite clinker refractoriness is as high as 1780, chemical stability strong, and good physical properties. 
(4) aluminum silicate refractory fiber. With light weight, high temperature resistance, good thermal stability, low thermal conductivity, heat capacity is small and the advantages of resistance to mechanical shock. Used in iron and steel, nonferrous metallurgy, electronics, petroleum, chemical, aerospace, atomic energy, defense and other industries. 
(5)  in magnesia and bauxite clinker as raw materials, add the appropriate binder, used for pouring ladle whole ladle lining has particularly good effects. 
(6)   manufacture alumina cement, abrasive materials, ceramic industry and chemical industry can be aluminum of various compound.

 

4. Calcined Bauxite Images

 

High Alumina 0-1mm 1-3mm 3-5mm Calcined Bauxite Granular for Road Making

High Alumina 0-1mm 1-3mm 3-5mm Calcined Bauxite Granular for Road Making

5. Calcined Bauxite Specification

 

 

Al2O3SiO2

Fe2O3

CaO+MgOK2O+NaODensityTiO2
80%6-14% min2%-3% max0.4% max0.05-1% max2.9-3.23.5% max
85%6-14% min2% max0.4% max0.05-1% max2.9-3.23.5% max
87%6-14% min2% max0.4% max0.05-1% max2.9-3.23.5% max
88%6-14% min2% max0.4% max0.05-1% max2.9-3.23.5% max

 

6.FAQ of Calcined Bauxite

1). Q: Are you a factory or trading company?

A: We are a factory.

2). Q: Where is your factory located? How can I visit there?

A: Our factory is located in ShanXi, HeNan, China. You are warmly welcomed to visit us!

3). Q: How can I get some samples?

A: Please connect me for samples

4). Q: Can the price be cheaper?

A: Of course, you will be offered a good discount for big amount.

 

 

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What are fire resistant level standards of class A fire resistant door?
Executive standard: GB12955-2008 Fire Door. Fire resistant level: Class A: 1.5h, B:1.0 h, C: 0.5 h. Thickness of door leaf: Class A: 50mm, B 45mm, C 40mm. Doorframe Specification: Class A, B, C. Door leaf form: Single open, double open, single open with glass, double open with glass, single open with glass and bright, double open with glass and bright, with a bright picture, Zimu glass Zimu glass with light. Doorframe Specification: Class A, B, Door leaf form: Single open, double open, single open with glass, double open with glass, single open with glass and brightness, double open with glass and brightness, double open with a lager door leaf and a smaller door leaf, double open with a lager door leaf and a smaller door leaf with glass, double open with a lager door leaf and a smaller door leaf with glass and brightness. Standard sizes: In line with GB5824-86 Hole Size of Building Doors and Windows."
Q:What are the advantages and disadvantages of new external wall fireproof and thermal inuslation matertials?
STP has a certain chance to self-destruct. After the sealing layer is damaged, the property will be bothered. When filling the foam glass, burst foam cement and low-strength glass fiber, the structural requirements are very high with big spraying limitations. As everyone knows that rock wool absorb organic matters, and the government do not allow us to use self-insulation, so it is not the mainstream with too low adoption rates. In fact the owners shouldn't worry about this problem. Since the developers have installed it for you, it is useless to worry about it. The other is that for those who want the original balcony closed up, if you want to shovel the original balcony wall insulation, you must pay attention to ask the construction team before you start. Because it is common that the cold bridges formed thereby will cause water seepage and moisture condensation in the balcony.
Q:Who can introduce the difference between galvanized fireproof coatings and steel structure fireproof materials?
Steel structure with heat galvanization has a process requirement, which is to spray fireproof coatings. Fireproof coatings have different functions and purposes from galvanized process. When the steel surface derusted, it generally needs to brush rich-zinc primer before spraying fireproof coating. Fireproof coating plan itself includes anticorrosion plan, and fireproof coating is just a layer of coating plans, which is an intermediate layer in general. Fireproof coating plan generally includes primer, fireproof coating and finishing paint. Some fireproof coatings can be directly painted on the bare steel elements without primer and finishing paint.
Q:It the Special Fire-Proof Material belonged to ceramics? Is there a national standard of the Special Fire-Proof Material?
The fiber and reinforcing material of the metal ceramic is also belonged to the Special Fire-Proof Material. ~~~~GB is too much trouble, GB online should ~~~ Lei Bao Refractories for you. The high temperature inorganic coating. 5. The refractory compound. 3. The high melting point oxide. You can search it on the internet according to the classification~~~~ The special refractories can be divided into five categories: 1. metal ceramic
Q:How to determine the fire resistance rating of the aluminium-plastic panel?
The fire resistance rating of the aluminium-plastic panel is determined by two indicators, namely national compulsory standard of GB8624 "Building Materials Combustion Performance Grading Method ", and GB/T17748 "Aluminium-plastic Composite Panel National Standard" . Classifications of combustion performance of building materials in our country are as follows: A class: Incombustible building materials; B1 class: Flame-retardant building materials; B2 class: combustible building material; B3 class: flammable building materials. The fire resistance rating of the aluminium-plastic composite panel shuld be no less than B1 class. 1. Detection indexes and requirements of fireproof aluminum-plastic composite panel (B1 class): (1) Conduct the test according to GB/T8625-88, the average leftover length of each test specimen should be more than 150mm, (any test piece should have leftover length), and the maximum average flue gas temperature of each test should be no more than 200 ℃; (2) Conduct the test according to GB/T8626-88, flame hight indicators.
Q:What's the requirements of fire-fighting criteria of heat insulating material?
It shouldn't be under than B2 level. Roofing insulation fire rating requirements: the ministry of public security, housing and urban-rural development department issued about printing and distributing the civil building external thermal insulation system and the interim provisions on the exterior wall decorative fireproof prescribed in the notice: roof grassroots adopted duration of fire resistance is the non-combustible component that shouldn't less than 1.00 h's. Its roof insulation materials should not be below B2; Otherwise, the combustion performance of insulating material should not be below the B1 level. The junction of the roof and wall, the insulation layer around the opening part of roof should use the grade A thermal insulation material to set level fire-fighting belt that width is not less than 500 mm.
Q:whether the fire resistant level of aerated concrete building blocks can reach the grade one?
it has fire resistant level, incombustible material,and it should reach grade one level.
Q:The history of refractory material
Q:What problems should be paid attention to while using refractory materials under a controlled atmosphere?
Pay attention to the performance of the materials, and the use of non oxide materials!
Q:What is the fire endurance of ceramsite concrete blocks?
The fire endurance of 240mm thick ceramsite concrete blocks is 2.9 hours. It is made by adding pottery into fine aggregate, using cement as binding material, by mechanical mixing, molding machinery and natural protection. Ceramsite building blocks are used as wall material, which can reduce workers' labour intensity. It saves work and material. There is no empty drum during rendering. It is not easy to produce fissure. It has sound insulation, good thermal insulation performance, and is convenient to decorate. Nails, expaned setscrew and no wood anvil can be directly hit into wall. Moreover, It has high firmness.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range