Technical Date

Material Specification

Nominal Diameter

DN50-DN600

Valve Body

Ductile Iron QT450-10

Nominal Pressure

PN10/PN16

Hand Wheel

Operation Temperature

-40°C~225°C

Bonnet

Flange Driling Standard

EN 1002-2 PN10/16

Gland Flange

Suface Treatment

Akzo Nobel Fusion Bonded Epoxy

Stem

2Cr13/ss410

Seal Material

EPDM or NBR


Application

Portable water, water distribution service & feed lines, sewage disposol, irrigation, fire protection pipe systerm, etc.

Wedge Nut

Carbon Steel

Thrust Washer

Brass

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What is the standard length of GB steel gate valve?
1, product standardsGeneral purpose valves, flanged connections, iron gate valves, GB/T 12232-2005General requirements for steel valves GB/T 12224-2005"Steel flat gate valves for pipelines" JB/T 5298-91Inspection and test of valves. JB/T 9092-1999Standard for safety evaluation of drinking water distribution equipment and protective materials GB/T 17219-1998
Q:What are the differences between the gate valve and the cut-off valve?
3, the valve is used in the system is relatively large, to close the gate off system; and the valve is used in the system is relatively small, and to adjust the flow quantity of the system, can not be closed gate and globe valves of different specifications for a variety of occasions, such as the valve rod the dark bar valve, gate valve, wedge gate valve, single valve, multi valve valve body structure is different, large volume. Generally large and nominal caliber DN50 mostly with gate valve, especially industrial high temperature, high pressure and other occasions.4, the cut-off valve is able to stop and adjust the flow, small footprint, small size, generally less than the nominal diameter, DN50 occasions use it. Two can be closed, in the flow of linear requirements are not high, you can adjust the flow. Just because of its structural characteristics of the valve to make its flow resistance, so there is a demand for throttling with a little more than the gate valve. In addition, the cut-off valve, whether it is a formal or reverse installed, in the opening and closing process, there is always a very difficult, and therefore can not do a great deal, or it is not easy to open and close. In addition, the sealing valve has the characteristics of one-way sealing effect, so that the utility model can prevent the working substance from flowing upstream
Q:What does gate valve Z44T-10-200 code mean?
The meaning of the model is standard, the landlord himself to check the JB/T308 standard, Baidu library some, and is free to download:JB/T 308-2004 valve type method of preparation clear EditionHttp://wenku.baidu.com/view/5f798850ad02de80d4d84036.htmlZ = gate valve4 = connection: flange4 = structure form: double gateT = sealing surface material: Copper10 = nominal pressure: 1.0MPa, followed by no letters indicate body material: Cast Iron200 = nominal path: DN200
Q:What are the working principles of the electric gate valve?
We see you what type of electric valve, is integral or ordinary type, if the overall type Denso took power on the line, is generally 380V and 220V power supply, and then according to their own needs and then open the signal line, in place and closing in place and remote control line, valve position feedback signal the commonly used 4~20ma over torque protection fault signal.
Q:What gate DH10016, AM
The first Z represents the gate valve (the initial consonant of the Chinese phonetic alphabet for the gate); the second 2 represents the drive mode of the valve, that is, electro hydraulic drive.
Q:What are the standards for the execution of cast iron dark pole gate valves?
Four, summary:1, cast iron gate valve is mainly used as a connection and cut off the role of medium. The opening and closing parts of the valve are ram, and the direction of movement of the gate is perpendicular to the direction of flow of the medium. Cast iron gate valve with ductile iron as the main material, the weight is very light, only about 20%~30% of the traditional gate valve;2, cast iron hidden rod gate valve belongs to the class of products, but also the successor to the traditional gate valve, the use of gate generated by the deformation of the compensation role, so that the valve to achieve good sealing effect. Cast iron dark rod valve with open and close the advantages of convenient, reliable sealing, good elastic memory, long service life, can be widely used in metallurgy, electricity, sewage, medicine, construction, food, textile, tap water, energy and other pipeline regulation and closure devices as.
Q:Does the tap belong to a stop valve or a gate valve?
Most taps are stop valves:1, gate valve (gate valve) is a headstock ram, RAM direction of motion perpendicular to the direction of the fluid, valve can only be fully open and fully closed doors, discomfort pumpsparameters vary, usually 5 degrees is not high, medium temperature is 2 degrees 52'. To improve its manufacturability, make up for the deviation of the angle of the sealing surface during processing. This gate is called an elastic ram.2, valve (stop, Globe, Valve) of the opening and closing parts are plug shaped valve, sealing surface is flat or sea cone, the valve along the center line of the valve seat in a straight line movement. Stem form of exercise (generic name: dark bar), but also lift rotating rod can be used to control air, water, steam, all kinds of corrosive media, mud, oil, metals and radioactive liquid media and other types of fluid flow. Therefore, this type of shut-off valve is very suitable for cutting or regulating and throttling. Because of the valve stem to open or close the trip is relatively short, but very reliable cut off function, and because changes in the valve seat and the valve stroke is proportional, is very suitable for flow regulation.The stop valve is an ascending stem type, and the handwheel rotates and rises along with the stem. Valve is hand wheel rotation, stem upward movement. Flow is not the same, the gate valve requires full open, the cut-off valve is not the same. The gate valve has no inlet and outlet direction requirements, and the cut-off valve has the required inlet and outlet!
Q:What does gate z41t-10 150 mean?
According to JB/T308-2004 "valve type programming method"Z gate valve4 flange connection1 Ming wedge single gateT sealing cover material is copper alloy10 nominal pressure PN10PN16 below no marked valve body code, body material is gray cast iron150 nominal size DN150
Q:Why is gate valve or butterfly valve used for water pump?
General pressure is small, use the butterfly valve, when the pressure is big, use the gate valve. The two main function of the valve is to adjust the flow and easy to overhaul.Zibo Boshan new Duke water supply equipment
Q:Why the valve can only be fully open and fully closed valve can adjust the flow?
Valve, if adjusted, it is easy to wash the sealing surface, resulting in sealing surface damage.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range