• AC Submersible Water Pump System 1
AC Submersible Water Pump

AC Submersible Water Pump

Ref Price:
get latest price
Loading Port:
Ningbo
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
35000台 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Specifications

1.CE certificate
2.Aluminium/Stainless steel/PPO
3.Mechanical seal:Ceramic-Graphite
4.Suction strainer:Stainless steel

QDX 1'' 1.5m3/h 220v ac submersible water pump

♦APPLICATION AREA

For countryside lifting water from,water supply and drainage of farmland,garden,and daily life.Drainage of industry ponding,building construction and breeding.

♦OPERATING LIMITS

Trans medium'sPH:6-8.5

Fluid temperature limit:<40°C

Max ambient temperature: :<40°C

Operating depth:5m

♦STRUCTION CHARACTERISTICS

Insulation class:E

Protection class;IP68

♦FEATURES

1. CE, GS certificate

2. 100% copper wire, automatic wiring

3. Cold-rolled silicon steel sheet, with high-speed punching, improve the efficiency and

precision.

4. CNC precision automatic lathe for smoother shaft.

5. Strict tests include water test, outgas test and performance test, ect.

6. Anti-rust treatment castings and electrophoresis.

7. 23-year experience, 1 year warranty.

Q:What are the general water pump failure, how to repair?
Two, pump speed is low(1) human factors. Some users because of original motor damage, may be accompanied by another motor, resulting in a flow of small, low head or even the consequences of Sheung shui.(2) the mechanical failure of the pump itself. Impeller and pump shaft fastening nut loose or deformation of the pump shaft bending, resulting in multi impeller, directly with the pump body friction, or bearing damage, are likely to reduce the pump speed.(3) the maintenance of the power machine is not working. The motor is lost because of winding burn, the change of winding number, wire diameter, wiring method, or failure in maintenance can not change the pump speed.
Q:Bolus dosage of infusion pumpWhat is the purpose of the pill dose control in the special safety standard for infusion pumps? If the risk is not properly controlled, what is the degree of risk? And how can the open infusion pump be used in this regard?
(1) the pellet dose in the safety standard of the infusion pump refers to the amount of liquid that is transported to the patient in a short period of time(two) pill dose limit is mainly to control the risk of accidental pill dosage. Especially after the mandatory requirements of pipe blockage in the elastic pipe storage liquid limit amount of agglomeration and the limitation of these methods to release pill dose.
Q:What are the constant pressure pumps?
CatalogBooster pump definitionMechanical classification, methane booster pump, pneumatic booster pumpGas-liquid booster pumpAir booster pumpChlorine booster pumpWorking principlefunctionMechanical installationMechanical selection of booster pump definitionMechanical classification, methane booster pump, pneumatic booster pumpGas-liquid booster pumpAir booster pumpChlorine booster pumpWorking principle
Q:What is the series of pumps? What is the difference between a unipolar and a multilevel? What is the meaning of each "first class"?
A single-stage pump is a pump with only one impeller. 2, a multistage pump is a pump with two or more impellers. The multistage pump can increase the pressure and lift the head higher. Level 1 means a booster impeller.
Q:What is the relationship between the minimum suction vacuum of a pump and the required cavitation?
When the pump is working, the liquid at the inlet of the impeller, due to a certain vacuum pressure will produce steam, the vaporization of the bubble in liquid particles under the impact of movement, the impeller and other metal surface erosion, thereby damaging the impeller and other metal
Q:How high can the pneumatic diaphragm pump be?
Diaphragm capacity, high temperature, pneumatic diaphragm pump ability, high temperatureMany users do not know how high the temperature resistant diaphragm pump, diaphragm pump either electric diaphragm pump or pneumatic diaphragm pump products it cannot do without diaphragm attachments, diaphragm materials mainly fluorine rubber, rubber, rubber, polyether road three EPDM, PTFE several, if not considering the gas temperature resistant diaphragm made of stainless steel. The temperature to 600 degrees of diaphragm pump diaphragm pump, but must use the diaphragm, so the diaphragm pump can Naiduo high temperature depends entirely on the diaphragm was affected by temperature, following to share various diaphragm pump diaphragm material and different material temperature choice diaphragm pump product right:
Q:What is cavitation, centrifugal pump cavitation phenomenon how to solve?
Centrifugal pump cavitation phenomenon how to solve?:Measures to improve cavitation resistance of centrifugal pumps(1) improve the design of the suction port of the centrifugal pump to the impeller. Increase flow area; the radius of curvature increases the impeller cover inlet section, reduce the flow accelerated sharply with pressure; reduce the thickness of the blade, and the blade inlet rounded, close to the streamline, can also reduce the acceleration and pressure flow around the blade head portion of the impeller and the blade inlet part; improve surface finish in order to reduce the resistance loss; the blade inlet edge extends to the impeller inlet, the liquid flow in advance to accept work pressure, improve.
Q:Harm of air pump and pump
If the liquid is not full, this situation is generally the suction pipe or pump shell leakage, then easy to cause cavitationHit the pump for centrifugal pumps, centrifugal pump is recommended to start closed, the discharge valve closed, starting is in the state of pump
Q:What does "anti pump" mean in pump operation?
Function: anti pump effect when used for pumping concrete pumping occurs overpressure, the pumping pressure is above 25MPA, the concrete conveying pipe out of ash, can be understood as the precursor of pipe blockage, at this time should immediately use the anti pump, the concrete from the conveying pipe in the suction into the hopper, thus preventing plugging happen
Q:How to adjust the flow of piston pump?
For the swashplate valve controlled by the solenoid valve, the swashplate is in an angle with the cylinder body, so the plunger is reciprocating in the pump cylinder when the cylinder rotates. It goes from 0 degrees to 180 degrees, that is, to the upper plunger position, the plunger cylinder volume gradually increased

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords