500mm Round Air Vent Diffuser pakistan Market

Ref Price:
Loading Port:
Ningbo
Payment Terms:
TT OR LC
Min Order Qty:
100 pc
Supply Capability:
999999 pc/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:


Specification of Air Diffuser

 

Round Diffuser 

 Supplying Air Diffusers 

-Frame Thickness: 1.0mm /0.8mm
-Any Size be customed 
-Powder Coated RAL 9010/9016


Data Details

round air diffusers

circular ceiling diffuser

round diffuser

NECK SIZE(mm)

DESCRIPTION OF GOODS

Diameter

100

1. Product name: round air diffuser

Diameter

125

2. Material: aluminum

Diameter

150

3. Powder coated: standard color, RAL 9010/9016

Diameter

160

4. Damper with

Diameter

200

5. reduce the flow resistance and noise.

Diameter

250

6. The products are easy to install and clean.

Diameter

300

7. adapt to centrel air-conditioning systems.

Diameter

350

8. other size/colors available.

Dimensions,colors,thickness, finished, disigns and other specification can be customized according to customers' request


Pictures show

500mm Round Air Vent  Diffuser pakistan Market

500mm Round Air Vent  Diffuser pakistan Market

500mm Round Air Vent  Diffuser pakistan Market

500mm Round Air Vent  Diffuser pakistan Market

500mm Round Air Vent  Diffuser pakistan Market

500mm Round Air Vent  Diffuser pakistan Market

 

Packing


PO shrink film bag for each pcs, ourter by export carton

PVC film + 4 plastic protection corners + carton box + closed wooden box optionally. 

Shipping:

within 21 days after deposit


Company Information

500mm Round Air Vent  Diffuser pakistan Market


FAQ


1, What's size do u have for round type diffuser?

A: We have face size from 150mm to 550mm,neck size from 250mm to 400mm

 

2, Do u still have other types ?

A: Yes, we have round diffuser/ rectangle diffuser/ linear grilles/ baseboard diffusers,etc

 

3, What's the most early delivery time?

A: Within 25 days for each 40'fcl




Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What is the working principle of the condenser?
Refrigeration principle general refrigerator compressor is the refrigerant by low temperature and low pressure gas compressed into high temperature and high pressure gas after temperature high pressure condenser into the liquid, through the throttle valve throttle valve, is a low temperature low pressure liquid. The liquid medium at low temperature and low pressure is sent into the evaporator to absorb heat and evaporate into low temperature and low pressure steam. It is transported into the compressor again, so as to complete the refrigeration cycle
Q:What are the parts of the outdoor unit?
Start capacitor compressor refrigerant cycle for capillary tube respectively high pressure pipe and low pressure pipe
Q:What are the differences and characteristics of D M type V compressor?
V is generally used in multi cylinder, large, high speed. The utility model has the advantages of full utilization of space, good heat dissipation and stable operation. Requirements for technical content is relatively high
Q:What is the function of the air conditioning condenser?
The high pressure and high temperature refrigerant gas discharged from the compressor enters the condenser coil outside the chamber and is cooled by the airflow outside the fan (about 35 degree C) driven by the fan
Q:How to deal with the liquid hammer phenomenon of compressor
The cause of liquid hammer is refrigerant or excessive lubrication, the liquid is too fast, the expansion valve (or valve) the regulation degree (opening) is too large, the heat load of evaporator (heat transfer) is not stable, large open type compressor suction valve open too fast (or unloading capacity too fast). System design and installation is unreasonable, abnormal shock may have caused the compressor
Q:How to repair air conditioning compressor?
The compressor power supply line card is generally burned, long time working in load condition caused by compressor, high current operation, the surface temperature of the compressor is higher. After dealing with the terminal fault, check the damage reason of the compressor terminal, the condenser fouling, the outdoor fan speed and the compressor capacitor will cause the compressor to run at high current and the surface temperature is too high
Q:What is the cause of the overload of the air conditioning compressor?
Dust on the outside condenser can be cleaned, and the heat insulation cotton wrapped on the compressor can be removed
Q:What are the types of condensers?
The condenser used in boiler, also called flue gas condenser, can effectively save the production cost, reduce the smoke exhaust temperature of boiler and raise the thermal efficiency of boiler. Boiler operation in line with national standards for energy conservation and emission reduction
Q:What is the mean of condenser?
In refrigeration plants, condensers are used to condense the cooling vapours of ammonia and freon. In petrochemical industry, condensers are used to condense hydrocarbons and other chemical vapors. A device in which steam is converted into liquid during distillation. Also called a condenser. All condensers operate by removing heat from the gas or steam.
Q:Refrigerators do not cool, compressors do not work, but very hot, what is the reason?
For the refrigerator electronic control system, in the case of electricity, with a multimeter measuring AC voltage blocking main control board of the input voltage and the output voltage is normal, the screen to show whether the compressor work? Each sensor is normal or not? The contact normal? If the input voltage and output voltage is normal without the main control board a fault

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range