Air vent grill Ceiling/Sidewall Registers/ diffuser 8x8 steel 4-way register

Ref Price:
Loading Port:
Qingdao
Payment Terms:
TT OR LC
Min Order Qty:
30000 PCS
Supply Capability:
100000 PCS/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Air vent grill  Ceiling/Sidewall Registers/ diffuser 8x8 steel 4-way register

ABS /PP/ PVC Plastic Air Diffusing Grille for Construction or building

Product Description of ABS /PP/ PVC Plastic Air Diffusing Grille for Construction or building

ABS /PP/ PVC Plastic Air Diffusing Grille for Construction or building Is Engineered polymer construction, Three-way deflection,Traditional styling,Integral multi-shutter damper with easy to use damper handle   For heating or cooling applications

The specification of ABS /PP/ PVC Plastic Air Diffusing Grille for Construction or building

Material Plastic(ABS/HIPS)

Color the frame is natural, the adaptor is black

Size mainly including150mmx300mm; 250mmx250mm; 300mmx300mm; 360mmx360mm; 360mmx540mm,and different sizes available upon your requirements

 

The feature of ABS /PP/ PVC Plastic Air Diffusing Grille for Construction or building :

1. The grille is made out of two levels of deflection blade sets perpendicular to each other,vertical blade set at the front and horizontal blade set at the back. 

2. The deflection blade sets can be adjustable manually.

3. The optional volume control damper can be added to the grille to form as register to further control the air volume.

4. Removable core, four direction air flow , the windows are assembled with each frame, the windows can be removed.

5. Easy mounting clip, easy to install and clean

6. Less condensation than metal grilles

The Advantage of ABS /PP/ PVC Plastic Air Diffusing Grille for Construction or building :

1. Surface is processed by anodic oxidation, so it is smooth, clean, beautiful, corrosion resistance.

2. Reasonable design, superior materials, manufacture of high precision, complete variety, easy installation and cleaning.

Package of ABS /PP/ PVC Plastic Air Diffusing Grille for Construction or building:

 the frames and the adaptors are separated in carton to save the room,the frames are packed 10pcs/carton, a poly bag for each frame.  

Lead Time 25-30 days

Payment Terms L/C, T/T

Delivery Terms Delivering by sea, air or express agent according to customer's requirements

Application of ABS /PP/ PVC Plastic Air Diffusing Grille for Construction or building :

It is mostly used on the sidewall outlet type air distribution. We always export to supermarket to USA ,CHILE ETC. For heating or cooling applications



4way Air register 
1.All steel construction 
2.For ceiling or sidewall installations 
3.Any color you would like. 

4. material: steel ,PVC,ABS etc

Air Registers

1.All steel construction.

2.Used for ceiling or sidewall installations and ideal for shallow duct installations.
3.1/2"spaced fins set at 40 degrees and 1-5/8"depth when fully opened.
4.Multi-shutter valve.
5.Four way deflection.
6.White powder-coating finish.
7.Any color you would like.

 

4SW Available Sizes(in.)
HTWIDTH
68101214
6X



8
X


10

X

12


X
14



X

FAQ :

1.What is the air grille?

It is made of plastic (ABS PVC,PP PE)or steel metal ,aluminum steel by mould.  It could be used for sidewall ,outletype air distribution, heating or cooling applications.

2.what kind of grille we have ?

We have ABS /PP/ PVC Plastic Air Diffusing Grille, aluminum swirl air diffusers, floor register, return air grille , wooden register ,plastic air grille, aluminum air grille, baseboard registers, celling side way registers, plastic air vent, blades dampers, etc .

3.what is the application of our grilles?

It could be used for sidewall ,outletype air distribution, heating or cooling applications.

4. what kinds of design we have ?

Please check our catalogue or website for reference. Or we could make design as your ideas .  We have professional technical team . they could make what you imagine.

 Air vent grill  Ceiling/Sidewall Registers/ diffuser 8x8 steel 4-way register


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What's the difference between compressor and air compressor?
Compressor: a wide range including air compressors, and others, such as oxygen, as the medium, both of which provide pressure, only the medium of compression is different
Q:How to deal with the liquid hammer phenomenon of compressor
If the compressor has occurred abnormal impact (knock or impact) sound, and will strongly shake vibration, indicating that the liquid is in the attack. Slight short term abnormal shocks may be of little concern, but often prolonged and heavy fluid shocks cause compressor deformation, rupture, and even breakage, which directly damages the compressor
Q:What is the Basic accessories for air conditioners?
with six system,Air duct system, refrigeration system, humidifying system, electric heating system, power distribution system and control protection system
Q:What are the types of condensers?
The condenser is often used for the condensation of the two steam at the end of the multi effect evaporator to ensure the vacuum of the final effect evaporator
Q:What are the types of compressors?
Displacement compressor is the ability to limit a certain amount of continuous air flow to a closed space, increasing the pressure
Q:What is the function of the refrigerator compressor?
Refrigerator is the use of evaporation, refrigeration or gasification absorption of heat to achieve the purpose of refrigeration
Q:What are the air compressors for?
The food and pharmaceutical industries use compressed air to stir the slurry
Q:What is the function of the hydraulic differential controller in the compressor?
When the oil pressure drops to insufficient to make the compressor work safely, it has not been restored to the set oil pressure value during the delay setting
Q:Refrigerators do not cool, compressors do not work, but very hot, what is the reason?
For the refrigerator electronic control system, in the case of electricity, with a multimeter measuring AC voltage blocking main control board of the input voltage and the output voltage is normal, the screen to show whether the compressor work? Each sensor is normal or not? The contact normal? If the input voltage and output voltage is normal without the main control board a fault
Q:What are the risk factors of condensers?
Combustible components are mainly acetylene and other hydrocarbons, acetylene is the most dangerous, the solubility in liquid oxygen is very low (5.6 * 10-6mg/L), it is easy to precipitate in solid state and cause explosion.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range