• Rubber Foam Heat Insulation Pipe for Chiller Systerms System 1
Rubber Foam Heat Insulation Pipe for Chiller Systerms

Rubber Foam Heat Insulation Pipe for Chiller Systerms

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
20 Cubic Meters m³
Supply Capability:
200000 Cubic Meters per Year m³/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

1.Product features: 

It is an elastomeric rubber based insulation material in the form of sheet and pipe with closed cell structure which doesn’t contain CFC halogen materials (chlorine, bromine, etc.) and PVC. It is manufactured to be used for air conditioning, heating and cooling systems.It has high thermal insulation value. It can be faced with aluminium foil and can be self-adhesive.

 

2. Application:

It is a black coloured elastomeric rubber based insulation material in the form of sheet and pipe with closed cell structure It is used on the exterior surfaces of the ducts and large diameter pipe lines in the heating, cooling and air conditioning systems for thermal insulation and condensation control purposes. It is developed to use at battleships, merchant ships, transportation systems; in areas where there are crowds of people such as business and entertainment places, hospitals, airports in order to reduce the emissions of smoke and poisonous gases. The sheets are adhered to the duct surface by using a special adhesive that it suggested. For the pipe applications, the pipe to be insulated and the rubber surface should fit properly and no gap should be left in between. Joints should be tightly sealed and they should be covered with insulation tape afterwards if necessary. Taping should not result in thickness loss. The application should be protected against distruption and rupture.

Q:How can the cooling water pipe of intermediate frequency cabinet be connected? What's the law?
Silicon controlled water jacket when taking over one side of the two groups: to optimize the water jacket together as one into a connected pipe following maintenance can remove a sawed off (or cut) leave allowance, too long to appear messy, not easy to smooth loop; after a pipe outlet, blowing verify whether the inlet or outlet side unobstructed; whether one should take over the symmetry, one is beautiful two is easy to find the import and export, reduce the chance of error later maintenance.
Q:What is the cause of the resonance in the cooling pipe of the central air conditioner?
Condensate pipe is said, the cause of this situation is mainly air conditioning pipe design is not good, exhaust pipe caused by internal condensation, water flow is not clear
Q:Volkswagen Sagitar cooling pipe, three pass joint, what is the name of
Hello This fitting is called a three - way connector. It is better to change aluminum because of the bad three - way connection. This is a common problem for volkswagen. After replacing the aluminum three pass, it can prevent future damage again.
Q:The cooling water pipe has condensed water. Can it be prevented from blowing up with the fan? Why?
Do not prevent the steam from freezing into water. The fan blows to accelerate the cooling. So it doesn't work
Q:What is the cooling water pipe of an automobile engine?Who can explain the introduction of the cooling water pipe of the automobile engine?
The cooling water pipe for automobile engine assembly in the presence of interference fit in the assembly process, if the amount of interference is too large, it is difficult to assemble, and easy to cause large deformation; if the amount of interference is too small, water and easy to fall off and Water Leakage. Carries on the simulation analysis using the finite element method, the assembly of different interference under the effect of size changes and pipe assembly force required and the amount of interference on the automobile engine cooling water pipe assembly to improve the best fit.
Q:How to scale the cooling water pipe of vacuum pump reducer?
Descaling ultrasonic, high pressure water or chemical reagents, descaling has not used, just know so many methods of descaling, or simply replace the tube to measure the economy of yourself!
Q:Rifled or smoothbore gun is? Why does it only use water cooling pipes, while anti-aircraft guns, infantry fighting vehicles and artillery guns do not? Thanks a lot!
Of course is the rifled gun, the gun is designed crash before the mid nineteenth Century. At present, only emphasizes the smoothbore high velocity direct tank gun of this demand, not the other needs, and in order to ensure the accuracy of long-range shooting only with rifled gun. There is enough space for warships. If there is a need for firing speed, water cooling systems can be used, and anti-aircraft guns and infantry fighting vehicles are not likely to be water-cooled in size and quality.
Q:Can you tell me how to distinguish the freezing pipes, cooling pipes and condensate pipes in HVAC engineering?
The chilled water is supplied at the end of the fan coil and the temperature is 7-18 degrees. The exterior is usually insulated with rubber and plastic;The cooling water is supplied to the refrigerator and is used without heat. The exterior is painted with green industrial paint;The condensed water pipe is generally installed at the lower part of the fan coil, and is connected with the water receiving plate, and introduces a floor drain or a collecting device without cold protection and brushing.
Q:My car is a 125CC assembly off-road vehicle. The engine is Tanaka's. Can this engine load the oil cooler?By the way, what is the lubrication of this engine?
I used to buy an oil cooler, but it doesn't work at all. Now I'm busy at home. I'll give it to you;Can only be installed in the oil port, due to the limitations of the design can only play the role of reducing pressure, the engine was actually with a waste pipe (exhaust gas purging and pressure), so this thing just decoration only, unless you love, if you consider the performance I suggest you modify the real oil cooler
Q:How to decorate the mass concrete cooling water pipe
Arrange the concrete according to the minimum section of the concrete and the temperature difference between the inside and outside of the concrete!
Our company invested in importing internationally advanced production technologies and equipment and set up a rubber and plastic insulation continuous foaming product line with an annual production capacity of 200,000 Cubic meters. Our company has become the largest company with the greatest variety of types and a specialized insulation material manufacture. The quality of our products come up to an internationally advanced level.

1. Manufacturer Overview

Location Shandong,China
Year Established 2009
Annual Output Value
Main Markets 30.00% Mid East
10.00% Southeast Asia
10.00% South America
9.00% Oceania
9.00% North America
8.00% South Asia
6.00% Eastern Asia
5.00% Western Europe
5.00% Eastern Europe
3.00% Northern Europe
2.00% Central America
2.00% Africa
1.00% Southern Europe
Company Certifications ISO 14001:2004;IQNET

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port Qingdao,Ningbo
Export Percentage 51% - 60%
No.of Employees in Trade Department 15 Day(s)
Language Spoken: English, Chinese
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords