Description Of 0.4KW ~400KW 50Hz/60Hz AC Motor Drive
CMAX frequency inverter is a high-quality, multi-function, low-noise variable frequency drive which is designed, developed and manufactured according to international standards. It can meet different needs of industrial conditions.The inverter applies advanced control technology of space voltage vector PWM, with functions of constant voltage control, power-off restart, dead zone compensation, automatic torque compensation, online modification parameter, high-speed impulse input, simple PLC and traverse
Features Of 0.4KW ~400KW 50Hz/60Hz AC Motor Drive
1).Adopts 16 bit microprocessor, sine wave PWM control2).Automatic torque ascension and automatic sliding compensation function
3).Output frequency 0.1-400 Hz
4).8 period of speed setting and 7 period can be running the program
5).Low noise, carrier frequency can from 1 kHz-15 kHz adjustment
6).Two paragraphs Acceleration and deceleration time and two segments of the S Curve slow and deceleration
7).Simulation frequency set acceptable 0-10 VDC, 4-20 mA
8).The built-in serial communication interface RS-485(baud rate can reach 38400)
9).Save energy running and automatic voltage stabilizing section function (AVR)
10).Adjustable V/F curve Acceleration and automatic and deceleration function
11).Simple vector control and built-in PID control, and the simple positioning function
12).Sleep/wake up function and zero velocity keep function
Structure Of 0.4KW ~400KW 50Hz/60Hz AC Motor Drive
Application Of 0.4KW ~400KW 50Hz/60Hz AC Motor Drive
★Textile: coarse spinner, spinning frame, wrap-knitting machine, loom, knitting machine, silk-spinning machine, etc.★Plastic: extruder, hauling machine, decorating machine, etc.
★Pharmacy: mixer, roaster, etc.
★Woodworking: engraving machine, sander, veneer peeling lathe, etc.
★Papermaking: single type papermaking machine, etc.
★Machine tool: non-core grinding machine, optical lens grinding machine, cutting mill, etc.
★Printing: cloth-washing machine, dye vat, etc.
★Cement: feeder, air blower, rotary furnace, mixer, crusher, etc
★Fan and pump: kinds of fans, blowers and pumps
Performance Of 0.4KW ~400KW 50Hz/60Hz AC Motor Drive
Item | Specification | |||||||
Input | Rated voltage | T4 series: Three phase 380v, ±15% | ||||||
Frequency | S/T2 series: Three/single phase 220V, ±15% | |||||||
50/60Hz ±5% | ||||||||
Output | Voltage | T4 series: Three phase 0-380V | ||||||
Frequency | S/T2 series: Three phase 0~220v | |||||||
0-400Hz | ||||||||
Overload ability | 150% rated current for 30s; 180% rated current for 1s; | |||||||
Dissipation | Cooling type | Forced Cooling | ||||||
Temperature protection | Heatsink temperature >85℃ trip protection against overheat | |||||||
Fan control | Heatsink temperature> 50℃, fan forced operation, frequency inverter continue work | |||||||
Control | Control mode | Open-loop vector control, V/F control | ||||||
Performance | Start torque | Open-loop vector control: 0.5Hz 180%; | ||||||
VF control: 0.5Hz 150% | ||||||||
Speed range | Open-loop vector control:1:150; | |||||||
VF control:1:100 | ||||||||
Speed control precision | Open-loop vector control: ±0.2%; | |||||||
VF control:±0.5% | ||||||||
Function | Channel of operation command | Keyboard control,terminal control,communication control | ||||||
Start mode | Direct start, DC injection braking before start, speed tracking before start | |||||||
DC injection braking | Start DC injection braking, stop DC injection braking | |||||||
Dynamic braking | Built-in braking unit | |||||||
Frequency source choice | Keyboard digital frequency setting, analog AVI setting | |||||||
PID control setting, telecommunications setting | ||||||||
Frequency resolution | Keypad setting:0.01Hz; Analog setting: 0.1% | |||||||
Carrier frequency | 1Khz~12Khz, | |||||||
Acc/Dec time | 0.1~6000.0s or 0.01~600.00s | |||||||
Signal | Analog input | AVI:0~10V | ||||||
ACI:4~20mA | ||||||||
Keyboard potentiometer input: 0~10V | ||||||||
Analog output | AFM:0~10V or 0~20mA, Select through JP1 jumper | |||||||
Digital input | A total of 28 kinds of function could be selected from S0 ~S5. | |||||||
Digital output | 1 channel open collector output(MO1-MCM) | |||||||
1 channel relay output( TA-TC normally open, TB-TC normally closed; | ||||||||
Communication Port | Communication protocol | Based on RS485 hardware, support standard MODBUS protocol. | ||||||
Display Functions | Four digital tube display | Can monitor the operation state of frequency inverter flexibly and conveniently. | ||||||
Installation | Humidity | Less than 90%RH | ||||||
condensation | ||||||||
Vibration | Less than0.6G | |||||||
Elevation | 0~1000m, reduce the rated specification 10% when lift 1000m for each. | |||||||
Storage temperature | -20~60℃ | |||||||
Structure | Defend degree | IP20 |
- Q:My inverter is the era TVF8000 series, the motor is 15KW6 pole motor, has been used for 3 years.
- For your situation about the summary of recommendations: First, check whether the motor overload and whether the leakage exceeded, Second, check and clean the inverter fan, if the room temperature is high, add the external fan to the inverter cooling Third, if none of the above, then please check the inverter module is burned, replace the module Fourth, if the inverter is no problem, then the motor and load the problem, if the motor problems are not resolved, then only re-select the inverter, please select the time to increase the margin
- Q:Do not the laptop directly connected to the power adapter?
- "Notebook do not power adapter", can only use the internal lithium battery power supply work. It can not directly use 220V AC power supply for it. 1, because the notebook product design power supply standard, is to use the matching power adapter power supply. That is, the power adapter will 220V civilian AC, rectifier filter, and then converted to low-voltage 19V DC, for the notebook to provide power supply;
- Q:11kw 6-pole motor can be used to adjust the inverter to 1800RPM?
- First, the inverter is no problem, I used so much to meet your needs ????? But to see if your motor can run at high speed, or whether the load is small, the power to have a general amount of redundancy. 6-pole motor synchronous speed of 1000, to meet your use to be transferred between 2000 or 1900, that is to say the frequency converter output frequency to be transferred to 90 to 100HZ. ????? Constant torque load is no problem, but the fan torque load to be a small job.
- Q:The motor is 2 pole with the inverter frequency to 50hz why the speed is only 1500 rpm
- The speed displayed on the display may be the speed of the deceleration or transmission. It is also possible that your inverter parameter ratio is not set, you need to modify and adjust, you want to help.
- Q:Is the laptop power adapter AC and DC?
- Most laptop power adapters can be used for 100 ~ 240V AC (50 / 60Hz). Basically, most of the notebook computers are external power supply, with a power cord and the host connection, which can reduce the size and weight of the host, only a very small number of models built in the host power.
- Q:Delta VFD-F frequency converter how to adjust the number of poles
- P148 look, this is to correspond to the number of poles of the motor, not to adjust the number of poles of the motor
- Q:Laptop warranty period is not over, the power adapter is broken, repair money?
- The general adapter is only one year warranty. And even some power warranty for three months. Go to the official website of the notebook, see the specific information of the computer, which includes the computer parts of the specific warranty date and expiration date. If the warranty period, as long as the purchase of the invoice, you can go to aftermarket replacement or maintenance. Remember to bring an invoice, warranty card. It can not find the warranty card must find the invoice. General power adapter is new.
- Q:Master Hello a machine requires 500 speed matching 6-pole motor frequency converter transferred to about 28HZ
- The belt rotation is calculated by the speed ratio. The current transferred to the motor by the inverter is approximately equal to the rated current of the motor, ie the motor's power is maximized.
- Q:B2b frequency how to speed
- AC motor speed control methods are four: frequency, transformer, variable pole and winding motor to change the rotor loop resistance of the speed control method. Its source is based on the motor speed formula: n = (1-s) * 60f / p where: n --- motor speed s --- motor slip f --- power frequency p --- motor pole Logarithm
- Q:Lenovo g450 laptop power adapter specifications is what?
- Input: 100-240V ~ 1.5A 50-60Hz Output: 19V - 4.74A
1. Manufacturer Overview |
|
---|---|
Location | Liaoning,China |
Year Established | 2001 |
Annual Output Value | US$5 Million - US$10 Million |
Main Markets | North America South America Eastern Europe Southeast Asia Africa Oceania Mid East Eastern Asia Western Europe |
Company Certifications | ISO9001 |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | DALIAN |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | ENGLISH,CHINESE |
b)Factory Information | |
Factory Size: | 5,000-10,000 square meters |
No. of Production Lines | Above 10 |
Contract Manufacturing | OEM Service Offered Design Service Offered Buyer Label Offered |
Product Price Range | Low and/or Average |
Send your message to us
0.4KW ~400KW 50Hz/60Hz AC Motor Drive
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1 pc pc
- Supply Capability:
- 5000 pcs per month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products
Hot Searches
Related keywords