• white  plastic can  motor running capacitors System 1
  • white  plastic can  motor running capacitors System 2
  • white  plastic can  motor running capacitors System 3
white  plastic can  motor running capacitors

white plastic can motor running capacitors

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing
Case:Round plastic case,quick connector terminals,anti moisture,anti explosion,good self-healing,good insulation etc.

AC film capacitors for general purpose applications (e.g. AC filters with harmonic frequencies exceeding 60 Hz), as well as for lighting and motor run applications.For the latter, AC capacitors are used in conjunction with asynchronous motors on single-phase mains supplies. They are designed for 50 or 60 Hz systems.


Applications:Asynchronous motors、Air conditioning、Domestic appliances、Compressors/pumps/garage、door openers、 Awning drives、 Heat pumps etc.



****Specifications****
Standard temperature
-40℃ ~ +85℃
Voltages Ratings
250V ~ 500V AC
Capacitance Range
1~60 uF
Applicable Standard
IEC60252-1:2011,GB/T3667.1-2005.UL810、EN60252-2:2011
Size


D±1mm
30
35
40
45
H±2mm
60-80
60-80
60-90
70-100


Q:What is the difference between the reactor and the capacitor?
Reactor is the inductive load, there are series and parallel in series, the series is mainly used to limit the short-circuit current, parallel mainly used for ultra-high voltage long-distance transmission, the compensation line capacitance. Capacitors are capacitive loads that are used primarily to compensate for reactive and energy storage. Inductance and capacitance combinations for filtering and so on.
Q:What is the phase-shifting capacitor, what is the difference between it and the general capacitor
And the phase-shifting capacitor has the function of changing the phase of the alternating current signal in addition to the characteristics of the general capacitor. The answer can be compensated by the power factor compensation in parallel with the phase-shifting capacitor, and the phase-shifting capacitor can be used to produce the phase-shifting capacitor fault diagnosis device.
Q:Does anyone know the difference between the stray inductance of the capacitor and the parasitic inductance?
With the increase in stray inductance, IGBT turn-on loss will be reduced, the diode loss will increase. Stray inductance may also cause oscillations, such as oscillations caused by current mutations, which may result in limited device use due to EMI or overvoltage limits.
Q:What are the differences between capacitors and capacitors?
There is a capacitor is a unit of the capacitor is a substantial object ah
Q:What kind of capacitance can be divided into?
Capacitors are often called capacitors. According to its structure can be divided into fixed capacitors, semi-variable capacitors, variable capacitors three.
Q:Capacitance for AC and DC effects?
Current waveform ahead of the voltage 90 degrees, in a sine wave cycle, half of the time ( Voltage waveform 0-90 degrees and 180-270 degrees) power to charge the capacitor, while the other half of the time (voltage waveform 90-180 degrees and 270-0 degrees) capacitance of the power discharge, the power and intact return power The
Q:What is the relationship between capacitance and voltage?
In your case, you can think of two capacitors as two containers, 5v capacity than 10v half (because they are 0.01uF),
Q:Use capacitance to do transformer how to calculate
According to this feature, if we connect a resistive element in series with a 1uF capacitor, the voltage obtained at both ends of the resistive element and the power dissipation it generates depends entirely on the characteristics of the resistive element.
Q:Capacitance can pass high frequency resistance low frequency principle
The capacitor has a charge and discharge time problem. When the positive half of the AC, to the capacitor charging moment, the circuit is a current flow, the equivalent of the channel, once the capacitor is charged, the circuit will not flow through, the equivalent of open circuit.
Q:Low voltage capacitor voltage 0.45 and 0.4 What is the difference between usage
0.45 capacitor used in the voltage level is high (for example, the transformer low voltage side voltage may reach 415V), with a tuned reactor (tuning reactor will increase the capacitor terminal voltage) situation; Note that the actual capacity of 0.45 capacitor nominal capacity (Actual voltage / 0.45) ^ 2 times;

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords