Water Mark SAA Stc Certified Electric All in One Heat Pump Water Heater
- Loading Port:
- SHANGHAI
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 10 unit
- Supply Capability:
- 50000 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Why air source heat pumps are more economical?
Rather than burning fuel as a source of heat, air source heat pumps work by transferring heat from one location to another. There is no need to light a fire, and no chimney or venting is required. Air source heat pumps are very efficient in heating and cooling indoor spaces. They can also heat household water, and as an added bonus, they typically offer energy cost savings.
If you’re wondering how air source heat pumps work, focus on basic refrigeration principles. Even in cold weather, outdoor air contains heat. An air source heat pump takes in outdoor air, extracts the heat from it, and uses that heat to warm your home. Standard air source heat pumps can extract heat from outdoor temperatures down to 5°. In warmer weather, the process reverses, and the pump keeps your home cool by extracting warm air indoors and transferring it outdoors.
Product Description
CECOX R290 all in one heat pump water heaters are compact domestic hot water heat pumps designed specifically for outdoor installation in Australia to supply domestic hot water to several draw-off points. Our heat pumps utilize the energy in the air to create environmentally friendly hot water all year round.
› CECOX hybrid heat pump water heater is designed for Australian conditions
› Max hot water temperature of this air to water heat pump is 75ºC due to backup electric heater
› 2 different sizes available, 200L and 270L to satisfy different families' demand for sanitary hot water, like hand basin, wash basin, shower, bath tub and kitchen sink.
› Compatible with Energy Management System for optimal use of grid
and solar energy
› heat pumps has a high operational reliability and long service life due to strict quality control
› Quiet operation of 45 db
› Can be installed indoors (13 m3 required)
- Q:What is the high voltage protection of heat pump water heater?
- The pump is then sent to the condenser (the air conditioner is the outdoor unit, and the heat pump is the heat exchange in the chamber or in the water tank...
- Q:What does "10e" on the monitor of the heat pump water heater mean?
- 2. Make sure the temperature sensor is open or shorted. Damaged parts need to be replaced.3, control whether the basic failure, unable to receive and issue signal control start. Need to replace the control circuit board.
- Q:What are the proper precautions for the proper use of air water heaters?
- Heat pump water heater must be installed or repaired by professionals, users can not install or repair themselves. The installation of heat pump water heater is completed. After checking, the heat pump water heater is connected. 2, close to the wall, with convenient installation, close to water and water, to reduce the pipeline length, split installation to winter the cold air exhausted to the outside (if necessary), reduce heat loss; the installation point near the wall outside the place, easy to cut a small hole for the winter will be cold air from outside, the best surface drainage export, to facilitate the discharge of condensate water
- Q:What is air source heat pump? What does energy saving refer mainly to?
- Its working principle is (by refrigerant / refrigerant) in the air to absorb heat, released into the water, circulating water heating, also lost a large amount of energy of low temperature air release to the kitchen or other place for refrigeration, kitchen or other refrigeration needs. When the air loses its energy and lowers its temperature, a large amount of water vapor is condensed, thereby releasing a considerably lower humidity of the air conditioner, which is equivalent to the dehumidification effect. Therefore, energy saving central hot water, kitchen (toilet) refrigeration and local dehumidification can be integrated into a whole, greatly improving the performance to price ratio.
- Q:My home is Mitra air source water heater,The upper temperature limit is 60 degrees,But now it's always warming up,In fact, the water temperature did not go up,But the temperature is rising,Sometimes a sudden jump of tens of degrees.High temperature alarms are also being issued.Tangle, looking for expert..........
- Encountered you this problem, temperature sensing system failure caused by. Usually controlled by a thermistor. It could be caused by its variable value damage. If you do not have the relevant professional knowledge, water heater is a high safety factor of electronic products, I suggest you let the factory after sale deal with this problem more professional, relatively safe! The above hope to help you ~!
- Q:Heat pump water heater high and low pressure in which range is the most appropriate?
- Most of the heat pump water temperature reached 40 degrees, high pressure of about 1.45MPa
- Q:Now tangled, do not know which brand to choose? GREE, Midea, Finney, cotton clouds, outesi! To see a lot of physical stores, but also on the Jingdong, Tmall read!
- 3, installation and after-sales maintenance is guaranteed? Finney is a free warranty for 6.5 yearsOf course, the proposal is best to find aftermarket convenience, maintenance is also convenient
- Q:What's the difference between a heater and an electric water heater?
- Is a kind of no electricity, no gas, no solar powered water heater, using the heat cycle heating will be low carbon environmental protection energy-saving device for heating tap water, built-in high efficiency heat exchanger, the hot water for bathing, washing, family, washing dishes, washing dishes, and so on. It is the ideal product for heating and providing hot water in winter for modern families and units. The solar energy and the heating water heater organic assembly installs together, one year four does not use the electricity, does not use the gas, the safe sanitation, uses hot water year by year.
- Q:The home of the air heater is installed last year, and later for a tank, but was put some snow, but also did not care to start heating, the recent period of time, heated to 60 degrees, soon cool, about 5 hours down to 20 excuse me, are power, with snow a relationship? Still busy, willing. Please understand the answer to prawns. Thank you
- Its power consumption is equal to the capacity of the electric water heater 1/4, the 1/3 of the gas water heater. The initial investment of air energy heat pump water heater (air source heat pump water heater) is three to five times of that of gas, natural gas and electric water heater, but its daily operation cost is low. Snow is refrigerant, refrigerant, also known as refrigerant, in some parts of the south, commonly known as snow. It is a working substance that circulates continuously in a refrigeration system and changes in its own state to achieve refrigeration. The refrigerant is vaporized in the evaporator by the heat of the cooling medium (water or air, etc.) and is transferred to the surrounding air or water by the heat in the condenser. It certainly has something to do with snow! Each degree of electric heating is 860K, the conversion rate is 92%, 200 liters water from 20 degrees to 70 degrees, warming 50 degrees,
- Q:Types of water heaters?Can you tell me the types of water heaters available now?
- Domestic water heater includes gas water heater, electric water heater, solar water heater and heat pump water heater four kinds.The gas water heater includes two types of displacement type and fast type, and the common is the fast gas water heater.
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Water Mark SAA Stc Certified Electric All in One Heat Pump Water Heater
- Loading Port:
- SHANGHAI
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 10 unit
- Supply Capability:
- 50000 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products
Hot Searches