• Railway Digital Signal Cable Wire for Building System 1
  • Railway Digital Signal Cable Wire for Building System 2
Railway Digital Signal Cable Wire for Building

Railway Digital Signal Cable Wire for Building

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT or LC
Min Order Qty:
1000 m
Supply Capability:
1000000 m/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Railway Digital Signal Cable

 

Product Description

Application

Cable is available for railway signal system connecting equipments and control facilities, could carry out the transportation of control information and electronic at 1MHz (analog signal), 2Mbit/s(digital signal), rated AC voltage 750V or DC 1100V and below.

 

Executive Standard

  TB/T3100-2004

Operational Performances:

  Ambient temperature of cable is -40~ +60°C,installation temperature no less than-10°C

  Long-term working temperature no more than +70°C,

  Cable allowed bending radius: 10 times of O.D. for non-armored cable, 15 times of O.D. for armored cable.

 

 

Model and Structure

Model

Name

Installation   requirements

Structure(Core   No.)

SPTYW   03

Skin-foam-skin   physical foaming PO insulated PE nutter sheathed digital signal cable

Pipeline,   hanging

4, 6,   8, 9,12, 14, 16, 19, 21,24,   28, 30, 33,37, 42, 44,48, 52, 56,61

SPTYW23

Skin-foam-skin   physical foaming PO insulated double steel tape armored PE outer sheathed   digital signal cable

Direct   bury, pipeline, hanging

SPTYWA23

Skin-foam-skin   physical foaming PO insulated synthesis sheathed PE nutter double steel tape   armored sheathed digital signal cable

SPTYWL23

Skin-foam-skin   physical foaming PO insulated A1 sheathed double steel tape armored PE nutter   sheathed digital signal cable

Product Electrical Characteristics

No.

Item

Unit

Index

Testing method

Reduction   formula

1

1.1

1.2

DC resistance at   20°C

Single conductor   DC resistance Working pair of conductor resistance imbalance

Ω/km

%

22.5±1.0≤1

GB/T3048.4

L/1000

-

2

DC 500V 20°C

Insulation   resistance DC 500V 20°C

Single   insulation core to other insulation core

connected with   screening and metal

MΩ·km

≥10000

GB/T3048. 6

1000/L

3

3.1

3.2

50Hz 2min   Insulation dielectric strength

Within cores

All cores   connect together (or each core) double screening and

metal sheath

V  

1000

2000

GB/T3048. 8

-

4

4.1

4.2

4.3

0.8~1.0kHz   Electricity capacity

4-core group   working capacity

Double-core   group working capacity

Single   insulation core connected to earth and other insulation core capacity

nF/km

28±3

35±4

≤70

GB/T5441.2

L/1000

5

5.1

5.2

5.3

0.8~1.0kHz   Coefficient of condenser coupling K1       Average Max

    Max

K9-K12   Average Max

    Max

4-core cable K   as the max index

pF/km

≤81

330

≤119

230

GB/T5441. 3

√L/1000

√L/1000

√L/1000

√L/1000

6

6.1

6.2

6.3

0.8~1.0kHz Capacity imbalance with nutter space

ea1,ea2 Average   Max

      Max

4-core cable   index as max

A11ow 10%   plates ea1,ea2 ≤1294pF/km

pF/km

≤330

800

GB/T5441.3

L/1000

7

7.1

7.2

Attenuation near   the end of the circuit

150kHz Within   the group

      Between the group

dB/km

≥51

≥55

GB/T5441.6

-10lg(L/ 1000)

1000kHz 300M or above

        Within the group

        Between the group

dB/km

≥37

≥42

GB/T5441.6

-

8

8.1

8.2

Defence end of   the circuit

150kHz Within the   group

      Between the group

1000kHz Within   the group

      Between the group

dB/km

≥52

≥62

≥39

≥49

GB/T5441.6

-10lg(L/ 1000)

No.

Item

Unit

Index

Testing method

Reduction   formula

9

Characteristic   impedance 20°C

0.55kHz

0. 85kHz

1.7kHz

2.0kHz

2.3kHz

Ω

675±68 550±33

396±24 367±22

343±21

325±20

163±17

155±16

GB/T5441. 7

-

10

Attenuation 20°C

0.55kHz

0. 85kHz

1.7kHz

2.0kHz

2.3kHz

2.6kHz

150kHz

1000kHz

dB/km

≤0.45

≤0.55

≤0.70

≤0.75

≤0.80

≤0.83

≤3.5

≤9.0

GB/T5441.7

L/ 1000

11

Phase angle

0.55 /0.85k/1.7/2.0/2.3/2.6kHz

o

-43±4.3 -42±4.2

-39±3.9

-38±3.8 -37±3.7 -36±3.6  

GB/T5441.7

-

12

(50H z)Ideal   shielding coefficient

50V/km~200V/km

0.8 Synthesis   sheath

0.2AL

sheath

GB/T5441.9

-

  Progress                                                  

 


Q: Four lines only reached a phase line, at the other end all charged, I use the digital pen! In addition, I often check the cable when the cable current through the dot digital pen voltage symbols sometimes have time to disappear, in other bare wires when the test keys are normal! What is this going on! Ask the heroes to give the younger brother a complete point of the answer! More
This is too difficult to give you a way to just try: with a fine wire rope, that is, lift the clothes on the stick so thick, the end of a bend, with a tape wrapped around the head, try can not wear, wear When the possibility of rotating wire rope, if you can go through the success of the half, the key is to use the wire through the more difficult, can only use the cord, hard-line 100% make life difficult.
Q: I would like to ask my new workshop power consumption of about 500KW, injection molding machine, 60KW . 40KW . 20KW . the other 20KW, how much should the wire? Respectively how to use lines and switches more
There must be no room for consultation I did not have to do for seven years lazy they want to do nothing irresponsible
Q: Rt, the charger did not change, has been no problem before, today just plugged into the charger, the results appear as if the problem, before the out of this problem, and now only ipad power off after the power can not be charged, and ipad start , Then immediately prompted the title, can not charge more
The proportion of the cross-sectional area of the cable through the embedded pipe is 20%
Q: Do not know why not mislead. The The The The The Fire resistance is IECGBBS6387. GB is the general principle of flame retardant and fire resistant wire and cable, quoted the above criteria...........................
Directly to find Dell customer service bar, the general warranty period are free replacement, unless the insurance of the. You can extend the warranty period, it seems you like to do the experiment.
Q: IPhone mobile phone data cable can not charge the power, the above shows the cable or accessories not certified can not work with the iPhone,
Wiring room refers to the distribution of the weak floor of the room, the weak point refers to the building weak vertical pipe
Q: Cable a fire line power and why the other did not pick up the line with a pen test also have electricity? Answer detailed point
Megohmmeter, such as measuring insulation normal, that is, induction power, the other line after grounding, the pen measured no electricity.
Q: Wire and cable CCC product consistency is what
PVC line, the market is better with plastic, plastic, . Wantong, etc., if only home improvement, then the brand requirements do not need so high. Small brands are the same, we see the quality. Network cable, then preferred Ann or TCL.
Q: What are the varieties of wire and cable (detailed point)
The meaning of the letter: W refers to the halogen-free, D refers to the low smoke, Z refers to the flame retardant WDZ is halogen-free low smoke flame retardant jacket power cable. WDZC refers to halogen-free low smoke C-class flame retardant
Q: This cable or accessory has not been certified and may not be able to work with this iphone reliably
The operation of the hydraulic pipe is very simple to see it will engage in their own, embedded more simple, and then get the construction site in accordance with the requirements of the drawings put away, tied with tie wire on the OK Mouth up the pipe to use cement bag to prevent good, to prevent the infusion of concrete, so buried even if the end
Q: What is the warranty period for wire and cable?
Wire and cable warranty period is 30 years of national warranty period. But the specific warranty period according to the type of wire and cable and the use of conditions and temperature and applicable methods to determine. General cable maintenance period is about 15 years, but to ensure that the normal use of the environment, such as the amount of temperature is below 70 degrees, but you are more than 70 working environment to use, of course, may not be used for a year. Therefore, the most important thing is to follow the instructions to use.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches