Railway Digital Signal Cable

 

Product Description

Application

Cable is available for railway signal system connecting equipments and control facilities, could carry out the transportation of control information and electronic at 1MHz (analog signal), 2Mbit/s(digital signal), rated AC voltage 750V or DC 1100V and below.

 

Executive Standard

  TB/T3100-2004

Operational Performances:

  Ambient temperature of cable is -40~ +60°C,installation temperature no less than-10°C

  Long-term working temperature no more than +70°C,

  Cable allowed bending radius: 10 times of O.D. for non-armored cable, 15 times of O.D. for armored cable.

 

 

Model and Structure

Model

Name

Installation   requirements

Structure(Core   No.)

SPTYW   03

Skin-foam-skin   physical foaming PO insulated PE nutter sheathed digital signal cable

Pipeline,   hanging

4, 6,   8, 9,12, 14, 16, 19, 21,24,   28, 30, 33,37, 42, 44,48, 52, 56,61

SPTYW23

Skin-foam-skin   physical foaming PO insulated double steel tape armored PE outer sheathed   digital signal cable

Direct   bury, pipeline, hanging

SPTYWA23

Skin-foam-skin   physical foaming PO insulated synthesis sheathed PE nutter double steel tape   armored sheathed digital signal cable

SPTYWL23

Skin-foam-skin   physical foaming PO insulated A1 sheathed double steel tape armored PE nutter   sheathed digital signal cable

Product Electrical Characteristics

No.

Item

Unit

Index

Testing method

Reduction   formula

1

1.1

1.2

DC resistance at   20°C

Single conductor   DC resistance Working pair of conductor resistance imbalance

Ω/km

%

22.5±1.0≤1

GB/T3048.4

L/1000

-

2

DC 500V 20°C

Insulation   resistance DC 500V 20°C

Single   insulation core to other insulation core

connected with   screening and metal

MΩ·km

≥10000

GB/T3048. 6

1000/L

3

3.1

3.2

50Hz 2min   Insulation dielectric strength

Within cores

All cores   connect together (or each core) double screening and

metal sheath

V  

1000

2000

GB/T3048. 8

-

4

4.1

4.2

4.3

0.8~1.0kHz   Electricity capacity

4-core group   working capacity

Double-core   group working capacity

Single   insulation core connected to earth and other insulation core capacity

nF/km

28±3

35±4

≤70

GB/T5441.2

L/1000

5

5.1

5.2

5.3

0.8~1.0kHz   Coefficient of condenser coupling K1       Average Max

    Max

K9-K12   Average Max

    Max

4-core cable K   as the max index

pF/km

≤81

330

≤119

230

GB/T5441. 3

√L/1000

√L/1000

√L/1000

√L/1000

6

6.1

6.2

6.3

0.8~1.0kHz Capacity imbalance with nutter space

ea1,ea2 Average   Max

      Max

4-core cable   index as max

A11ow 10%   plates ea1,ea2 ≤1294pF/km

pF/km

≤330

800

GB/T5441.3

L/1000

7

7.1

7.2

Attenuation near   the end of the circuit

150kHz Within   the group

      Between the group

dB/km

≥51

≥55

GB/T5441.6

-10lg(L/ 1000)

1000kHz 300M or above

        Within the group

        Between the group

dB/km

≥37

≥42

GB/T5441.6

-

8

8.1

8.2

Defence end of   the circuit

150kHz Within the   group

      Between the group

1000kHz Within   the group

      Between the group

dB/km

≥52

≥62

≥39

≥49

GB/T5441.6

-10lg(L/ 1000)

No.

Item

Unit

Index

Testing method

Reduction   formula

9

Characteristic   impedance 20°C

0.55kHz

0. 85kHz

1.7kHz

2.0kHz

2.3kHz

Ω

675±68 550±33

396±24 367±22

343±21

325±20

163±17

155±16

GB/T5441. 7

-

10

Attenuation 20°C

0.55kHz

0. 85kHz

1.7kHz

2.0kHz

2.3kHz

2.6kHz

150kHz

1000kHz

dB/km

≤0.45

≤0.55

≤0.70

≤0.75

≤0.80

≤0.83

≤3.5

≤9.0

GB/T5441.7

L/ 1000

11

Phase angle

0.55 /0.85k/1.7/2.0/2.3/2.6kHz

o

-43±4.3 -42±4.2

-39±3.9

-38±3.8 -37±3.7 -36±3.6  

GB/T5441.7

-

12

(50H z)Ideal   shielding coefficient

50V/km~200V/km

0.8 Synthesis   sheath

0.2AL

sheath

GB/T5441.9

-

  Progress                                                  

 


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Why this cable has not yet been certified
The manufacture of wire and cable is completely different from that of most electromechanical products
Q:When pouring concrete is how to put the tube
Oh, the pipeline is poured before the layout according to the design drawings.
Q:Galvanized wire tube buried to do anti - corrosion do
Galvanized pipe itself with anti-corrosion coating, you can not do anti-corrosion.
Q:Where should the inner diameter of the plastic tube of the cable be at least the number of times the outer diameter of the cable?
You are not very clear: how to start again? 300μF capacitor is normal? If the sound is normal (very small) after no-load start, the cable and the motor temperature are normal, the coil can be judged to be normal
Q:Wire printed on the word what way to erase
Wipe with water that day. You can also use ink thinner
Q:2.5 square copper (green, with the threading tube) can withstand the highest power of several kilowatts,
Should be the line group: lighting a group of 2.5 square millimeters, an ordinary socket a group of 4 square millimeters, air conditioning a group of 6 square millimeters, kitchen and bathroom appliances a group of 4 square millimeters, so that after the down is not enough to put a separate group You say the high-power electrical outlet, the line to the square of the square mm to see your home how high-power electrical appliances, but advise you to use these high-power electrical appliances before the first to determine its current good, More than your home appliance load!
Q:Home leaked, installed in the floor below the wire was blisters will have any security risks? How can the water inside the pipe to dry
Can do so, it seems that less a HDMI high-definition line
Q:Fiber optic cable split box, integrated wiring box, cable terminal box, cable transfer box difference
Outdoor fire line must use fire-resistant KVV cable, wear pipe protection.
Q:How to distinguish between power cables and electrical wiring on drawings
After the opening is not, if not open like a downstairs to delete the C disk file on the line, if the boot is necessary to set up, sit down little hands and feet.
Q:What is the difference between a kbg threading pipe and a PVC threading pipe?
You should be said: 2-way cross-linked polyethylene insulated PVC sheathed cable 4 core 185 square millimeters, SC is steel pipe, diameter . FC is laying method dark cover the floor or floor. Personal opinion, hope to help you!

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range