Medium Voltage Drive VFD 1800KW 6KV HIVERT-Y 06/220
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- 100000 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Perfect Power Output Section
The HIVERT general MV VFD adopts the power cells connected in series and voltage overlapping method (i.e. Power cells multi-level cascade technology), it can output the perfect PWM sinusoidal waveform (see Figure 2 and Figure 3). It has the following advantages:
1. No need for the additional output filter
2. Directly driving general synchronous or asynchronous motor
3. No de-rating operation on the motor
4. No dV/dt stress on the insulation of motor and cables
5. No torque ripple, extending service life of motors and mechanism
6. No cable length restriction within the acceptable voltage drop.
The general MV VFD has the following protection functions and features:
Overload and over-current
Phase loss and grounding
Over voltage
Overheat
Current limit
Redundant control power supply
Cell Bypass (optional)
Cabinet door alarm
Phase-Lock function
Synchronous Switching between VFD and Grid system
Soft start of motor
High efficiency >98% (VFD at full-load)
Electrical Isolation by the optic fiber
Built-in PID regulator
RS485 communication with the protocol, Modbus as standard, optional Profibus-DP, Ethernet,etc
Accurate fault records, easy to check fault history
Compact structure and layout, customized design is available
- Q:What is the characteristic of the variable pole speed method?
- Seven, hydraulic coupler speed control method The hydraulic coupler is a hydraulic drive, generally composed of a pump wheel and a turbine, which collectively referred to as a working wheel and placed in a sealed housing. The shell is filled with a certain amount of working fluid, when the pump wheel in the prime mover driven under the rotation, in which the liquid by the blade to promote the rotation, under the action of centrifugal force along the outer ring into the turbine wheel, in the same direction to the Turbine blades are thrusted to drive the production machinery. The power transfer capacity of the hydraulic coupler is consistent with the size of the relative filling fluid in the shell. In the course of work, change the liquid filling rate can change the coupler's turbine speed, made stepless speed regulation, which is characterized by: power to adapt to a large range, from several tens of kilowatts to thousands of kilowatts to meet the different power needs; Simple, reliable, easy to use and maintenance, and low cost; small size, can accommodate large; easy to control and easy to achieve automatic control. This method is suitable for fan, pump speed.
- Q:How to choose a Siemens inverter for a 5.5KW three-phase motor (2 pole)?
- Siemens frequency conversion dedicated input / output filter, reactor, you contact us but smell it, the quality is guaranteed. We look forward to cooperation.
- Q:A water supply project, how to choose electrodes and frequency converters, such as giving a 7-storey water supply
- 2 pump power: If there is a tank, optional small pump, or should see how many households, fixed flow.
- Q:HP laptop power adapter how to open
- HP notebook power adapter for the full size of the design, you can follow the following steps to dismantle: 1, notebook computer power adapter for the injection molding package or with a strong adhesive glue, without any screws, so generally only with violence to crack. However, as long as the method properly, after the dismantling of the power adapter can be restored to the original, do not carefully observe almost no traces of open. 2, the power adapter on the side of the side of the white paper, with an electric knife edge along the power adapter between the gap between the cover, and then hit the electric knife with a hammer, so that the electric knife from the adapter between the upper and lower cover go with. In the different positions of the gap between the upper and lower covers of the adapter, use the tip of the electric knife to be scratched along the gap. When the upper and lower covers are first split, the depth of the tool is deep and then the upper and lower covers of the adapter are separated. 3, then open the shell of the power adapter, you can see the adapter circuit outside the package with a copper shield, with a knife to cut the shielding tape on the tape, and then use the soldering iron shield and the internal circuit board connected to the two Solder joints, you can remove the shield. 4, between the shield and the circuit board is also separated by a layer of thick plastic film, and then cut off the knife after the United States, you can see the circuit board "Lushan true"
- Q:6-pole motor, speed 8000 rpm, corresponding to the frequency converter output frequency is how much?
- The synchronous speed of the motor is n = 60f / p P is the pole pair number, and f is the power supply frequency. The pole pair number of the 6 pole motor is 3. Therefore, f = n * p / 60 = 8000 * 3/60 = 400Hz.
- Q:18: 5 kilowatts bipolar multi-pole pump motor with inverter
- Under normal circumstances, with 15KW inverter on it.
- Q:What is the difference between the electronic governor and the frequency converter on the motor speed regulation?
- Electronic governor is for single-phase motor, by changing the access winding resistance and capacitance to adjust the motor speed, the speed of the power supply power for the output does not change, so this speed is not an energy Type of speed control methods, such as home for the use of fans and the like. Inverter speed is the original direct input three-phase asynchronous motor power first access to the inverter, in the inverter through the PWM and other electronic converter technology to rectify the frequency AC, inverter, become a frequency controllable AC In the input to the motor, in the motor running through the V / F control, output torque control, vector control and other control methods to adjust the frequency, change the loop current, to achieve energy-saving operation, especially in the light load energy efficiency is obvious, An energy-saving products that have been widely promoted and applied
- Q:My inverter is the era TVF8000 series, the motor is 15KW6 pole motor, has been used for 3 years.
- For your situation about the summary of recommendations: First, check whether the motor overload and whether the leakage exceeded, Second, check and clean the inverter fan, if the room temperature is high, add the external fan to the inverter cooling Third, if none of the above, then please check the inverter module is burned, replace the module Fourth, if the inverter is no problem, then the motor and load the problem, if the motor problems are not resolved, then only re-select the inverter, please select the time to increase the margin
- Q:What is the application of variable frequency speed control?
- Frequency conversion is to change the power supply frequency, thus regulating the load, play a lower power consumption, reduce losses, extend the service life of the role. Frequency translation. Frequency conversion technology is the core of the inverter, through the conversion of the power supply frequency to achieve the motor speed regulation of the automatic adjustment of the 50Hz fixed-line frequency to 30-130 Hz change frequency. At the same time, also make the power supply voltage to adapt to the range of 142-270V, to solve the power grid voltage instability caused by electrical work problems. By changing the AC frequency of the way to achieve the AC control technology is called frequency conversion technology.
- Q:Why the number of motor poles increased, the inverter capacity will increase
- The power of the three-phase motor is equal to the root number of 3 times the line current and the line voltage of the product again good with the power factor. Can also be 3 times the phase current and phase voltage of the good product and then good to power factor. The frequency converter should match the rated current of the motor, not the power of the motor.
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Medium Voltage Drive VFD 1800KW 6KV HIVERT-Y 06/220
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- 100000 unit/month
OKorder Service Pledge