Technical specifications
Table 2.3: Technical Parameters of QD200 Series Frequency Inverters
ITEM | SPECIFICATIONS | |
Main Input | Rated voltage and frequency | Single-phase 200V class: 200V-240V,50Hz/60Hz |
3-phase 400V class: 380V-480V , 50Hz/60Hz | ||
Allowable value of change | Voltage: 380V-15% ~ 480V+10%; Frequency: ±15% | |
Main output | Output voltage | Maximum output voltage equals to input voltage |
Output frequency | 0.5 Hz to 400 Hz | |
Overload capacity | 150% of rated output current for 60s, 200% of rated output current for 2s | |
Control performance | Modulation mode | 3-phase PWM, 2-phase PWM |
Control mode | V/f control for constant torque, V/f control for quadratic load, vector control without PG (open loop control),Energy-saving | |
Setting method of run command | Outer terminal, keyboard panel or serial communication | |
Setting method of speed command | Analog setting, keyboard, serial communication, UP/DOWN speed setting from external terminal | |
Speed setting resolution | Keyboard: 0.1 Hz | |
Analog setting: 0.05/50Hz (10bit) | ||
Speed control precision | V/f control:±2% | |
vector control without PG (open loop control): ±0.2% | ||
Speed control range | V/f control 1:40 | |
vector control without PG (open loop control) 1:200 | ||
Acceleration and Deceleration Time | 0-3200.0s | |
switching frequency | 1.5 kHz ~ 12 kHz, according to junction temperature automatically reduce the switching frequency | |
Analog input | Number | 2 ways: AI1、AI2 |
Type | DC voltage or DC current | |
Maximum input range | AI1: 0 to 5VDC, 0 to 10VDC, 0/4 to 20mA DC receivable AI2: 0 to 10VDC or PTC probe input receivable | |
Analog output | Number | 1 way: AO1 |
Type | DC voltage or DC current | |
Maximum input range | Voltage output: 0 to 10V, Current output: 0/4 to 20mA | |
logic input | Number | 0.75kw-11kW:LI1,LI2,LI3,LI4,AI1,AI2 15kW-500kW:LI,LI2,LI3,LI4,LI5,LI6,LI7,LI8,AI1,AI2 note:2 virtual logic input, capable of configuring AI1 and AI2 into logic input port (positive logic or negative logic) |
Type | Source or Sink | |
Maximum input range | 0-24VDC |
ITEM | SPECIFICATIONS | |
logic output | Number | 0.75kW-11kW: pulse signal output (LO-CLO)、relay output 1(T1A、T1B、T1C) 15kW-500kW:pulse signal output(LO-CLO)、relay output 1、2(T1A-T1B-T1C、T2A-T2B-T2C) |
pulse signal output | ||
relay output | RA-RB-RC, including a NO contact and a NC contact Maximum switch capacity: T1A,T1B: 3A at 250VAC, or 4A at 30VDC T2A,T2B: 2A at 250VAC or 30VDC | |
Serial communication interface | RS485 interface supports Modbus protocol. | |
Display | 4-digit LED digital display | For display of frequency setting, output frequency, fault code and parameter setting etc. |
Environment | Standard | Development of VSC200 series frequency inverters follows strict international standards and relevant recommended IEC and EN standards for control devices, especially IEC/EN61800-5-1 and IEC/EN61800-3. |
Altitude | Derating unnecessary when altitude is 1000m or below (Derating necessary at altitude higher than 1000m) | |
Ambient environment | 0.75kW-11kW: Reliable operation at -10 ~ 50°C without derating. When top protective cover is taken off, the environment temperature can be as high as +50 °C. Above +50 °C, the current drops by 2.2% for each rise of 1 °C in temperature. 15kW-500kW: Reliable operation at -10 ~ 40°C without derating. Storage: -25 ~ 70°C | |
Humidity | No condensed water or drip at 5 ~ 95%, In accordance with IEC60068-2-3 | |
Impact strength | 15gn for continuous 11ms, In accordance with IEC/EN60068-2-27 | |
Maximum antipollution capacity | Class 2, in accordance with IEC/EN61800-5-1 | |
Structure | Protection level | Top: IP41 (without removing the protective top cover). Other parts: IP20 |
Cooling Method | Forced Air cooling | |
Installation method | Wall mounted |
- Q: How to choose the right inverter?
- 1, constant power load During the operation of the load device, the power remains constant. Such as machine tools, cutting machines, paper machines and so on. For example: a marble cutting machine frequency conversion system, is a constant power load, load inertia, inverter selection configuration A power with the G-type machine, plus the braking unit and braking resistor.
- Q: Is it possible to use a different laptop's power adapter?
- For the power adapter, whether access to equipment, the following aspects of the measurement standards: Interface form The interface plug and socket used must be dimensioned. Voltage size The output voltage of the adapter is the same as the required voltage of the connected device (eg notebook). Inconsistencies may not be able to start or burn the device properly. Current or power The power of the adapter is greater than the maximum power required by the device. Power is not enough, may cause the voltage to drop, the adapter is hot, or burn the adapter. More than the above, the use of more power of the power adapter, while meeting the interface and voltage conditions, it can be replaced.
- Q: My Lenovo v450 laptop power adapter should be bad how to match?
- Lenovo V450 laptop power adapter is broken, the warranty period is not artificially damaged can be directly to the Lenovo aftermarket replacement adapter can be outside the warranty period to pay maintenance, it is recommended to use the original power adapter the best. Laptop charger (Laptop Charger), that is, laptop charger. The traditional notebook charger can only output a single voltage to a type of notebook computer charging, the industry called the traditional notebook power adapter for the single band notebook charger (mainly in order to distinguish between the universal notebook charger.)
- Q: How can a variable speed multi - speed three - phase asynchronous motor be controlled by a frequency converter?
- Although the waste, but can be used, we use the frequency band with two-speed motor when the output is connected to the fast three terminals, you can refer to the next
- Q: Laptop power adapter aging
- This should be no, play the game automatically shut down should be detected other
- Q: What is the adapter?
- Easy Alliance Electronics (China) Co., Ltd. (eNetwork) currently has a different series, different types of adapters, original authentic, and sold at competitive prices.
- Q: What is the difference between AC and DC frequency converters?
- L inverter air conditioner refrigeration system components: inverter air conditioner by the compressor, evaporator, condenser, electromagnetic four-way valve, electronic expansion valve, defrost valve, double capillary and other components (see Figure II), work, air conditioner Room needs, automatic control of the inverter output frequency higher AC, the motor speed to speed up, the compressor cooling capacity increased to achieve the purpose of rapid cooling or heating, on the contrary, when the room cooling or heating less, Compressor to normal speed or lower speed operation, therefore, inverter air conditioner has a continuous cooling capacity adjustment, making the room temperature fluctuations smaller. In the process of compressor operation, the microcomputer system controls the inverter compressor at the same time, controls the opening degree of the electronic expansion valve, maintains the proper refrigerant flow, and directly changes the flow of the refrigerant in the evaporator to change its state, the compressor The speed corresponds to the opening degree of the expansion valve, and the displacement of the compressor corresponds to the supply amount of the expansion valve, so that the degree of superheat is not so large that the capacity of the evaporator is maximized, so that the refrigeration system The most efficient control.
- Q: What is the maximum speed adjustable for a 4-stage motor with a rated frequency of 50Hz / 60Hz?
- Motor speed and frequency of the formula N = 60f / p In the above formula N - the speed of the motor (r / min); 60 - per minute (seconds); F - power frequency (Hirsch); P - pole pairs of motor rotating magnetic fields. China provides the standard power frequency f = 50 weeks / second, so the rotation of the magnetic field of the size of the theoretical diameter only with the magnetic pole. The number of pole pairs is large, and the rotational speed of the rotating magnetic field is low.
- Q: Whether the inverter can control the start and stop of the horizontal monopole centrifugal pump
- Can be installed by a simple float level control to achieve, the general frequency is to constant pressure, of course, start and stop is completely controlable Oh. It's good for the pump to start the speed change
- Q: Oil-free vertical vacuum pump why a little negative pressure inverter on the torque limit
- Or the star of the three-phase motor to the corner, so that after the rectifier inverter into a 220-volt three-phase AC ...