2014 One Air Conditioning Chiller Syetem
- Loading Port:
- Qingdao
- Payment Terms:
- L/C,T/T
- Min Order Qty:
- 1 Unit set
- Supply Capability:
- 5000 Units per Year set/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Part of technical data R407c
Model | Unit | 60 | 68 | 88 | 88 | 108 | 108 | 128 |
Capacity |
| |||||||
Cooling capacity* | kW | 60 | 68 | 88 | 80 | 108 | 108 | 128 |
Cooling power input* | kW | 19.26 | 21 | 26.3 | 26.25 | 34.38 | 34.41 | 41.36 |
Heating capacity** | kW | 65 | 70 | 95 | 88 | 110.8 | 110.8 | 135 |
Heating power input** | kW | 19.26 | 20.8 | 26.16 | 26.25 | 34.38 | 34.41 | 40.92 |
Compressor |
| |||||||
Type | / | Scroll | ||||||
Qty/refrigerant circuit | Nr | 4/4 | 2/2 | 2/2 | 6/6 | 3/3 | 6/6 | 4/4 |
Axial fan |
| |||||||
Quantity | Nr | 2 | 2 | 2 | 3 | 3 | 3 | 2 |
Airflow | m3/h | 24000 | 24000 | 35800 | 33000 | 39000 | 39000 | 48000 |
Evaporator |
| |||||||
Type | / | S | T | T | S | S | S | S |
Water flow | m3/h | 10.3 | 11.7 | 15.1 | 13.7 | 17.2 | 17.2 | 22 |
Water side pressure drop *** | kPa | 43 | 43 | 42 | 41 | 41 | 41 | 41 |
Noise level**** | dB(A) | 70 | 74 | 72 | 70 | 73 | 73 | 77 |
Dimensions |
| |||||||
Length | mm | 1980 | 2110 | 2170 | 3100 | 3100 | 3100 | 2200 |
Width | mm | 1005 | 1080 | 1285 | 1050 | 1050 | 1050 | 1560 |
Height | mm | 1750 | 1900 | 2050 | 1900 | 1900 | 1900 | 2160 |
Net weight | kg | 700 | 800 | 950 | 920 | 1000 | 1000 | 1450 |
FAQ
Q1:Why is it important to use home air conditioner filters?
A:Without them you can clog up vital parts of the heating or cooling components that can be difficult to clean out and can cause severe damage that will be much more expensive to repair than the inconvenience of replacing a filter once a month.
Q2:What is VRF Air Conditioning System?
A:VRF air-conditioning systems owe their growing popularity to their ability to meet a wide range of requirements.
- Q:The demolition of household air conditioner?
- Air conditioning units operating process: Switching (including replacement of indoor machine or need to recycle refrigerant), violate compasses operation may cause refrigerant recycling compressor, air conditioner switching is also a kind of frequent business, all need to be in the process of switching refrigerant recycling, but if the improper operation, will also be the worst effects of the compressor explosion. Operation: compressor running low voltage side to close the high-pressure valve, air conditioning system to run for a few minutes, the compressor suction air leakage explosion. Funnelled process analysis: due to air conditioner refrigeration system, the system internal cause low voltage side is funnelled has no refrigerant or a small amount of residual refrigerant, cause the compressor suction air and close running on the high side, the final explosion. Compressor explosion: the mechanism of air conditioner refrigeration cycle system high side blocked - compressor running to inhale air for several minutes, the compressor overheating - frozen oil overheating vaporization - compressor inside a huge increase in oil and gas mixture, temperature, pressure increased to achieve a certain pressure, temperature, mixture combustion of oil and gas compressor, a sharp rise in the temperature, pressure and compressive strength than the compressor shell and the compressor shell burst. Response: in front of the air conditioning switching operations, you must first open air conditioning to check operation parameters. Confirm the various performance parameters of the normal pressure gauge on the three-way valve process pipe connections, can close the high-pressure valve for refrigerant recovery, downtime when pressure is 0.1 MPa.
- Q:Household air conditioning refrigeration quality measure standard is what?
- Summer air conditioning refrigeration standard is: air-conditioning electricity work half an hour later, the temperature of the outlet should be about 10-15 degrees below the temperature of the inlet to the normal. Know, isn't it?
- Q:How to correctly use of household air conditioning pressure gauge
- 1) check for the temperature of the fluid tube and muffler and condensation. Start the air conditioning runs under the condition of refrigeration 20 min, if any condensation on the outdoor unit back to the valve and the muffler, muffler fingered temperature was lower than that for the temperature of the fluid pipe, shows refrigerant in the system is enough, air conditioning running normally. Has one of following cases, indicates lack of refrigeration: (1) for the liquid condensation tube, muffler condensation; (2) for liquid pipe frost; (3) for liquid tube not dewing cool, muffler, nor too cold; (4) for fluid pipe and trachea is not cool. (2) measure the pressure of the valve in the back. Add the pressure gauge connected to air conditioning low pressure Angle valve inlet, measuring its operation at low pressure, under normal circumstances, when the environment temperature is about 30 ℃, refrigeration operation of low pressure is 0.45 ~ 0.55 Mpa, in heat pump air conditioning heating runtime should be 1.8 Mpa, if under the pressure, shows lack of refrigerant. The lower the pressure, the greater the leakage. If the basic pressure, explain refrigerant has. (3) fill nitrogen pressure (1.5 Mpa nitrogen filling the), observe the four two connecting pipe joint, gas liquid valve stem, and whether there is oil stains in areas such as the liquid mouth. There are oil stains for leaks. (4) using the leak detector to find the general part, and then coated with soap and water, if there are air bubbles appeared, to be funnelled namely.
- Q:Home air conditioning is not how to use, how long does it need to open it
- Refrigeration and heating guarantee respectively run once a year.
- Q:Can an air conditioner help with allergies?
- Indeed, allergies can be alleviated with the assistance of an air conditioner. The air conditioner functions by effectively filtering and circulating the air, thereby eliminating allergens like pollen, dust mites, pet dander, and mold spores from the indoor environment. By diminishing the presence of these allergens in the air, individuals suffering from allergies can experience relief. Moreover, air conditioners aid in regulating humidity levels, which in turn hinders the growth of mold and mildew, thereby further reducing allergens in the air. Nonetheless, to ensure optimal performance in reducing allergens, it is crucial to adequately maintain and clean the air conditioner filters.
- Q:I want to air conditioning in the sitting room and bedroom, someone says yi tuo 2 well, some people say that separate two little good. Please renew what, how YangZhuang more appropriate? Thank you very much!
- Yituo 2 air conditioning by out of the market, the sitting room and bedroom with a large and a small fission machine, air conditioning (beautiful cloth tube, maintenance convenient), common room per square - take refrigerating capacity / 100 w - 150 w can be.
- Q:Do you need frequency conversion for household air-conditioning
- Variable frequency and variable frequency difference is how much energy consumption. The meaning of is to save electricity... Frequency conversion will save electricity.. Other functionality and performance and frequency are the same... You want to save electricity to buy inverter
- Q:Can I run my air conditioner 24/7?
- No, it is not recommended to run your air conditioner 24/7 as it can put excessive strain on the unit and result in higher energy consumption and potential damage. It is advisable to give the AC periodic rest periods to maintain its efficiency and longevity.
- Q:Use air conditioning air intake
- Air intake? There is no fresh air in the vast majority of domestic air conditioning!
- Q:A typical household air conditioner how much is the normal work of electric current
- If it is haier frequency converter, with the loss of the indoor temperature, the compressor and the working power of the fan will decline gradually, then the working current of air conditioning, will be less than 7.2 A. (to around 1.5 A) to A minimum.
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
2014 One Air Conditioning Chiller Syetem
- Loading Port:
- Qingdao
- Payment Terms:
- L/C,T/T
- Min Order Qty:
- 1 Unit set
- Supply Capability:
- 5000 Units per Year set/month
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products
Hot Searches
Related keywords