SET SCREW EMT COUPLING-ZINC,EMT couplings

Ref Price:
$0.05 - 2.50 / pc
Loading Port:
Ningbo
Payment Terms:
TT or LC
Min Order Qty:
1000 pc
Supply Capability:
300000 pc/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Description:
EMT couplings are used in dry location to connect the ends of two unthreaded EMT conduits together. EMT aluminum set-screw couplings provide concrete tight connections when taped. Additionally, These set-screw couplings eliminate the need to thread bald conduits to fit old threaded couplings. EMT conduit couplings are pure aluminum material for excellent corrosion protection in damp location.


EMT Coupling
American Standard
UL Standard 514B
Size: Zinc 1/2" to 4"
Aluminum 1/2" to 2"
Set-screw type
Material: Zinc/Aluminum Die Cast


Applications:

These set-screw couplings are used in dry locations to connect   the ends of two EMT thinwall conduits together. topele’ die-cast aluminum, set-screw couplings provide concrete-tight connections when taped and properly secured with the included set-screw. Topele’ set-screw electrical couplings are rated for electrical applications above 600 volts.

SET SCREW EMT COUPLING-ZINC,EMT couplings

 

 

 

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Decoration doubt, what kind of wall can not open the horizontal groove?
Excretion training is the use of positive reinforcement, that is, a variety of food, toys, the best time to reward
Q:Apple 6 Charging Why always show this cable has not yet been certified
Is the power directly out of the CPU power supply line or on this basis and added the extension line
Q:How much of the cable with the switch?
The switch is not selected according to the cable and is selected according to the current. The cable is determined by the size of the power (converted to current) and the distance from which the distance is far. The greater the power distance, the greater the cross-sectional area of the required cable. For example: 15KW motor selection cable current I = P / 1.732UcosΦ = 15 / 1.732 / 0.38 / 0.8 = 28A if it is close (within tens of meters), copper cable 6 square millimeters, aluminum cable 10 square millimeters. If it is in the distance (a few hundred meters), copper cable 10 square millimeters, aluminum cable 16 square millimeters. If it is long distance (close to kilometers), copper cable 16 square millimeters, aluminum cable 25 square millimeters. The switch is regardless of distance, completely based on the load current to choose, generally according to the load current of 1.5 times to 2 times to choose.
Q:7 kilowatts of electricity with what specifications of the wire
1 square millimeters can flow 4A current, 1KW380V, then the current is about P = UI about 2.6A7KW, 380V, then the current is about 18A, each with the line to share 18/3 = 6A2.5 square mm of copper on it. Of the area need to take . probably 6 level. V is probably 7KW220VI = p / u = 7000/220 = 31A. Then need 10 square millimeters of copper.
Q:Is the cable head made of every building?
Building in accordance with the floor or unit configuration distribution box, there are office buildings using a total box. Where there is a cable out of the situation, must be wrapped to make the cable head, according to the choice of distribution box circuit breaker wiring crimp or not crimp the cable terminal. In other words, the cable head must be made, but not necessarily crimp the cable terminal.
Q:25 square copper cable how much money one meter?
3000w electrical work at 220V voltage is about 13.6A (current = power divided by voltage). Copper core line of the working current is generally a square 4-6A. That is to say you use 3-4 square power cord more secure.
Q:How to solve the computer connected to the TV audio problem, how to set the computer and TV audio separation
In accordance with the relevant safety regulations, the power cable should not be parallel to the top of the thermal pipe laying, when can not be avoided, the interval distance should not be less than 1000mm, during which should also take effective insulation measures. Power cable and thermal pipe cross, the thermal pipe insulation layer, the separation distance should be not less than 500mm, no insulation layer should not be less than 1000mm, and in the cross with the insulation board to be protected, the length of the insulation board should not be less than d + 2000mm (d for the thermal pipe insulation layer diameter).
Q:1000 kW 600 m cable to use much
Three-phase 380V, 1000 kilowatts load, the working current is about: 1899A. The total area of copper cable is not less than: 1200 mm2 copper cable. . the cable is usually a few or several groups of wires (at least two each) twisted from the rope-like cable, each group of wires are insulated from each other, and often around a center twisted, the entire outer package Highly insulated cover. Cable with internal power, external insulation characteristics. . the cable has power cables, control cables, compensation cables, shielded cables, high temperature cables, computer cables, signal cables, coaxial cables, fire cables, marine cables, mining cables, aluminum cables and so on. They are composed of single or multi-strand wire and insulation layer, used to connect the circuit, electrical appliances and so on.
Q:5 air conditioning can be used 4 square cable
You do not use the 9V power supply, a long time will burn the router.You'd better measure the original adapter voltage, if you want to extend the power cord, it is best to use a thick line of reliable connection, you can not start now, you can not start Depending on whether the extension line is too thin, causing the voltage drop too much.It is necessary to extend the front end of the adapter can extend the 220V power cord.
Q:What is the type of pipe that is marked as KBG pipe?
If no color distinction, 100 meters after you know which line of the fire line which line? The

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range