COMPRESSION EMT CONNECTOR-ZINC,EMT couplings

Ref Price:
$0.05 - 2.50 / pc
Loading Port:
Ningbo
Payment Terms:
TT or LC
Min Order Qty:
1000 pc
Supply Capability:
300000 pc/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

 EMT Compression Connector
American Standard, NPT Thread
UL Standard 514B
Size: 1/2" to 4"
Material: Zinc
Technics: Casting


EMT compression connectors are used in dry locations to bond unthreaded EMT conduit to electrical junction boxes or enclosures. TOPELE EMT compression  connectors provide concrete tight connections when taped Its steel construction maintains mechanical protection and solid grounding of the conduit to the designated electrical junction box or enclosure. They eliminate the need to thread bald conduits to attach them to electrical junction boxes or enclosures. Compression connectors are pure zinc material for excellent corrosion protection.


Applications:

EMT connector: Joins steel EMT conduit to Electrical box
•Connect & effectively bond EMT conduit to steel outlet boxes, load centers & other metal enclosures
• in concrete-tight applications when taped
•Reversible locknut designed to cut through protective coatings on boxes & enclosures
•UL standard for safety
•Application type : EMT
•Electrical Product Type : Standard Fitting
•Fitting type : Connector
•Indoor/Outdoor : Indoor / outdoor
•Paintable/Stainable : No
•Trade Size (in.) : [1/2"] [3/4"] [1"] [1-1/4"] [1-1/2"] [2"][2-1/2"] [3"] [4"]

 

 

 

 

 

 

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Decoration doubt, what kind of wall can not open the horizontal groove?
Reply to the landlord: I read a part of the literature, more Google is aware of the following part may be your reference weak construction specifications 1
Q:Apple 6 Charging Why always show this cable has not yet been certified
Motherboard and power supply problem, the best way is to try to USB2.0 ban on the use of USB1.1 but will be slower
Q:How to distinguish how many pairs of cable with a large heat shrink tubing
Yellow line is video, red and white are audio, you can only pick one!
Q:How much of the cable with the switch?
Switch = (2-2.5) current three-phase current = P / 1.732 / 0.38 / 0.8 single-phase current = P / 0.22 / 0.8
Q:7 kilowatts of electricity with what specifications of the wire
7 kilowatts of electricity with what specifications of the wire if it is single-phase 220V, then 7 kilowatts of current is 7000 × 220V = 31.8A, check the electrical manual 4 square copper wire interception is 33A, to meet the requirements.
Q:Is the cable head made of every building?
Building in accordance with the floor or unit configuration distribution box, there are office buildings using a total box. Where there is a cable out of the situation, must be wrapped to make the cable head, according to the choice of distribution box circuit breaker wiring crimp or not crimp the cable terminal. In other words, the cable head must be made, but not necessarily crimp the cable terminal.
Q:The difference between nylon balls and geese and ducks
As long as the cable is thick enough, 20 meters of the basic loss can be ignored.
Q:25 square copper cable how much money one meter?
There is no 1..2..4.5 square wire. The family uses most of the four wires with 1.. 1.. 2.5 and 4. Power 1KW Approx. 5A.3KW Approx. 15A.2.5 square copper wire can be used. Plug or empty open (25A).
Q:5 air conditioning can be used 4 square cable
Lengthened low voltage side, the line resistance increases, the voltage drop increases. Reduced load capacity. So that the router due to insufficient supply voltage and can not work properly. It is not allowed to use 9V power supply. Voltage is too high, the router part of the internal power supply increased power, heat increased, it is possible to burn the router. It is necessary to extend the power cord, I suggest you extend the power supply side (220V one end) safe and reliable. Increase the voltage to increase the supply current, in the electrical working voltage range (with the electrical work voltage range) is allowed, too low electrical appliances can not work properly. Too high there is the risk of burning appliances, according to your actual situation, marked 5V0.2A that the router works at rated voltage, so the way to improve the supply voltage is not applicable. So you can only improve the power supply power (that is, you say to increase the power supply current rather than voltage). With the reserve power, it will provide enough current at the rated voltage (the router as a resistor, from I = U / R, you can know the danger of increasing the voltage) need help please message
Q:What is the type of pipe that is marked as KBG pipe?
If no color distinction, 100 meters after you know which line of the fire line which line? The

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range