Product Description:

Quick Details

Model Number:
Two wing
Standard:
BS
Type:
Two wing
Certification:
ISO 9001:2000, ISO/TS 16949
Material:
ductile iron
Surface:
polishing, grinding, plating or according to your requist

Packaging & Delivery

Packaging Detail:Plastic bag, pallet packing, carton box, by customer's requirement
Delivery Detail:within 30days after payment

Specifications

Two wing Butterfly Wing Nuts
1>Excellent dimension accuracy
2>Finished: per your requirements
3>factory directly supply

Two wing Butterfly Wing Nuts

We supply kinds of metal parts totally according to clients' drawings and samples and special requirement.

Product Description

1. Material: Ductile iron .

2. Sizes: Inner hole Dia 15/17mm.

We have different sizes ,types of wing nut to meet your needs, save your cost .

3. Weight:  0.35kg,thread pitch:  10.0mm.(or 6.35mm)

4. Surface: White  Zinic , Yellow Zinic or painted, self color

5 Thread:casted or machine tap.

Our Services

1. 12000M2 standard modern workshop guarantee production capability to satisfy the customers needs

2.  Our Independent quality control department,Which make sure the quality of all products

3.  Our efficient and experienced sales team ,provide friendly and thoughtful service for clients from all over the world


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:When to ask for formwork support
3, the height of the column in the following 2m must be set up a large cross bar, to maintain the stability of the column; when the height of the column is greater than 2m, should be set up a large cross bar, a large step distance of 1.8m.4, every big pillar template should be set two directions of the bar. At the same time, each 4 upright columns are provided with a pair of scissors braces.
Q:Steel support pre pressure construction should meet the requirements
The slenderness ratio of the support member and the thickness ratio of the plate should be based on the different fortification intensity, according to the current national standard "code for seismic design of buildings" GB 50011.4 support can be used with the original set of steel reinforced concrete members and reliable connection, and measures should be taken to support the reliable seismic force is transferred to the foundation.5 new steel support can be used for the calculation of both ends hinged, and only assume the role of earthquake.
Q:How to reinforce the lower part of the construction elevator on the garage roof
Crane hoisting torque weight of 5 meters X5 meters X 1. Four meters tower crane basis weight calculation of the four tons of free height tower crane foundation plane load per plane is not calculated
Q:How to calculate the axial force of steel support in deep foundation pit
Preload is generally not more than 450kN, because of the use of pile anchor structure is mostly sand, silt, or clay, anti pulling force of this stratum and anchor is limited, 450kN means that the prestressing design tension reaches 450/0.95~450/0.7, which is basically the ultimate anchor in this ordinary formation, if not met to consider the encryption of anchor spacing.
Q:Is the calculation of the axial force of concrete support and steel support
In addition to calculating the compressive strength of steel support to meet the requirements, but also to calculate the stability of the requirements to meet. Because the steel support is generally longer and thinner, it may be unstable.
Q:What is the maximum value of the support settlement on the beam
Germany developed a method of strengthening reinforced concrete structures with steel plates, which adopts the double component epoxy resin adhesive steel plate or other steel piece pasted on the surface of concrete, constitute a concrete - steel composite adhesive three-phase system * by reinforced concrete member after pasting steel plate, can partly replace the reinforced by steel plate the role of * therefore, when the bearing capacity of reinforced concrete members due to insufficient or deformation, cracks affect the structure of normal use, can use adhesive paste to steel reinforced concrete members outside the appropriate location, to meet the bearing of #.
Q:Does the basement steel frame support column need concrete pouring
A: if it is built at the same time design and construction in the case of the bottom note, in the pouring of the floor, the anchor bolt and the embedded steel plate according to the design requirements of embedded anchor bolts and embedded steel plate specifications to determine the design according to the design unit
Q:What is the size and wall thickness of the steel support inside and outside?
Press locking and fastening connection KGB wall thickness and JDG are very different,JDG in addition to 16 of the pipe wall thickness of 1.2, the rest are all of the 1.6.KGB tube wall thickness and pipe size. More than 16 also have more than 1.2, and more than 1 of theKBG metal threading pipe and JDG metal threading pipe are widely used in the construction of electrical engineering of 1kV and below, because of its advantages such as convenient construction, low cost, superior performance, complete specifications and complete products
Q:Steel support can not be removed if the deformation of the foundation pit, how to solve
You don't know is that part of the steel support: purlin, cross brace down, vertical brace, gusset
Q:Steel structure steel support (roof brace) what set quota?
Support, steel (steel brace) specificationsare steel / steel / steel /H steel box / other steel etc..

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range