marine stainless steel railing fitting

Ref Price:
$0.03 / pc
Loading Port:
Qingdao
Payment Terms:
TT LC
Min Order Qty:
100 pcs pc
Supply Capability:
300000pcs Per Month pc/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Usage: Pipe Clamp
Material: steel、matel;Galvanized iron ,stainles
Band width:3mm/20mm
Connection:welding
Model number:As your requirement
Structure:Swivel clamp
Certificate:ISO9001:2008
Feature:
1.Use the open internal and external circle structure,and with screw fixed.It is effectively to solve the problem that when small diameter solft tube connect the hared tube,it is easy appear dead angle,and liquid or gas leakage problem.Easy structure,Easy maked.
2.Edge is no burrfree,it is ability to prevent the tube damaged
3.By a efficiently hydrogen relief treatment,long-term use needn't to worry fracture and other problems
Surface: zinc plated Packaging
4.Accord with DIN3017 Standard.By 48 hours salt and fog test,it has a good corrosion resistance
5.By our last 48 hours elastic test,to insure a high strength mechanical properties.
6.Easy to fix.
Working Temp: -40 ℃ ~ 110 ℃
Size:3/8" 1/2" 3/4" 1" 1 1/4" 1 1/2" 2" 2 1/2
Structure: Suspension Clamp and so on On-time shipment and pre-shipment product quality safeguards clamp is mainly used in automobiles,tractors, ships, gasoline engine, and so on each kind of mechanical
device for oil, gas, hydraulic hose connector, various types of
rubber tube interface must join parts fastening.
Detail: plywood case ,pallets or any other package as buyer's requirements
Delivery Detail: about 20-30days

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:How to use the multimeter to check the grounding wire is normal?
The multimeter is not able to detect whether the earth wire is normal. Grounding resistance detection is usually done by bridge method, grounding resistance tester and clamp type meter grounding resistance tester. They all need special test equipment.
Q:BM822A type digital clamp meter is how to measure current?
Clamp meter working principle: clamp meter is composed of a current transformer and current meter assembly. The iron core of the current transformer can be opened when the wrench is tightened; the wire through which the current is measured can be cut through the opening of the iron core without cutting off, and when the wrench is released, the iron core is closed. Through the test circuit of the core, the wire becomes the primary coil of the current transformer, in which the current is induced in the two coil through the current. Thus, the current meter connected with the two coil is instructed to measure the current of the line to be measured. A table can shift through the switch, the scale change. But the switch is not allowed to operate when charged. Clamp meter general accuracy is not high, usually 2.5 ~ 5. In order to facilitate the use of the table there are different ranges of switching switches for measuring different levels of current and voltage measurement function.
Q:Clamp ammeters how to measure resistance, current, voltage
A multimeter and ordinary multimeter is not the same as lies in: as the current measurement to the meter in series in the circuit, so under normal circumstances, using ordinary multimeter to measure the current required power cut, multimeter or current meter, current transformer primary side connected in series in the circuit. Then power is measured, and a multimeter can measure the current power. A multimeter than the ordinary multimeter more than one meter, the meter is made according to the principle of the current transformer, specially used for measuring alternating current. Its working principle is as follows: a part of current meter measurement million by the current transformer and current measuring part composed of 000 table. The iron core of the mutual inductor is provided with a movable part and is connected with the handle. When the utility model is used, the movable iron core is opened by pressing the handle. The wires of the current to be measured are put into the jaw and the handle is closed to close the iron core.
Q:According to the three-phase current and voltage, the reactive power and power factor are calculated
Clamp meter is the current transformer measurement is a valid value.
Q:How to use the 266CLAMPMETER clamp multimeter
When measuring, the current to be measured should be estimated and the proper range should be chosen. If you can't estimate, you can select a larger number of courses, then reduce the number of files to the appropriate gear. When converting the range gear, it must be done in the case of no electricity or under the opening of the jaw so as not to damage the meter.
Q:How do I add refrigerant to the wall mounted air conditioner?
Turn on the air conditioner and turn on the refrigerant tank valve.3. Open the valve of the two way valve of the meter valve.4, at this time began to add refrigerant, watch the pressure rising gradually.5, hands up to 0.5~0.6MPa, the notes of refrigerant right, then you can turn off the refrigerant tank valve and valve meter valve. It takes about 30 minutes to fill in the refrigerant.6, if the refrigerant filling capacity is insufficient, the valve will appear all frosted, and then need to add.7, if the refrigerant filling volume is too much, there will be air valve and liquid valve all frosted, then need to drain refrigerant.
Q:The multimeter, megohmmeters and use clamp meter.
Preparation prior to use1, check whether the European watch can work properly, place the watch horizontally, and empty the handle of the euro watch. The pointer should point to. O, and then slowly shake the handle, so that L and E two terminal pile output line instantaneous short, the pointer should quickly point to zero. Note that the L and E cannot be shorted too long when shaking the handle, otherwise it will damage the watch. ,2, check the electrical equipment and circuit being tested to see if all the power has been cut off. Never allow equipment and lines to be charged with a European watch.3, before measuring, deal with equipment and line the first discharge capacitor discharge equipment or line so as not to endanger the personal safety and damage megohmmeters, it can reduce the measurement error at the same time, attention will be the test point to wipe clean.
Q:The reason that the phase current meter of the three-phase asynchronous motor is too low and the other two phases is normal is that it is too normal
If a new motor appears, one phase current is low, and the other two phases are normal. It is possible that the current is low, the phase voltage is high, or the current meter and the transformer have problems
Q:Excuse me, great God. What is a DC clamp type?
Clamp type table (sometimes called the table clamp, clamp meter) AC / DC clamp meter as the daily maintenance work is one of the essential test tool, mainly used to test the voltage, current, frequency and other related parameters, it has high resolution and precision testing and more testing function. It works the same way:
Q:A selection table clamp type table
Because the clamp table itself is of low precision, small current measurement, can adopt the following methods: first, the measured circuit of the wire around a few times, were measured and then put into the jaw in clamp meter. The current clamp meter indicating the value of the actual value is not measured, the actual current should be divided by the wire clamp meter readings for winding the coil number.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range