Product Description:

Usage: Pipe Clamp
Material: steel、matel;Galvanized iron ,stainles
Band width:3mm/20mm
Connection:welding
Model number:As your requirement
Structure:Swivel clamp
Certificate:ISO9001:2008
Feature:
1.Use the open internal and external circle structure,and with screw fixed.It is effectively to solve the problem that when small diameter solft tube connect the hared tube,it is easy appear dead angle,and liquid or gas leakage problem.Easy structure,Easy maked.
2.Edge is no burrfree,it is ability to prevent the tube damaged
3.By a efficiently hydrogen relief treatment,long-term use needn't to worry fracture and other problems
Surface: zinc plated Packaging
4.Accord with DIN3017 Standard.By 48 hours salt and fog test,it has a good corrosion resistance
5.By our last 48 hours elastic test,to insure a high strength mechanical properties.
6.Easy to fix.
Working Temp: -40 ℃ ~ 110 ℃
Size:3/8" 1/2" 3/4" 1" 1 1/4" 1 1/2" 2" 2 1/2
Structure: Suspension Clamp and so on On-time shipment and pre-shipment product quality safeguards clamp is mainly used in automobiles,tractors, ships, gasoline engine, and so on each kind of mechanical
device for oil, gas, hydraulic hose connector, various types of
rubber tube interface must join parts fastening.
Detail: plywood case ,pallets or any other package as buyer's requirements
Delivery Detail: about 20-30days

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Which is the best way to export lj2085 and lj2025 fishing gear?
The measured current is calculated for the fishing power, but the measurement of the maximum input current, to load a certain amount of fishing with, can bring high power light bulbs, or on the site with the sun, back type fishing device (such as SUSAN-735MP) with 500W solar lamp, solar lamp is two LJ-2025NP 1000W.
Q:How to maintain and maintain the communication and power room?
AC / DC clamp type meter. AC / DC clamp meter as the daily maintenance work is one of the essential test tool, mainly used to test the voltage, current, frequency and other related parameters, it has high resolution and precision testing and more testing function. At present, the maintenance personnel usually use the FLUKE of the United States F337 AC / DC Clamp Meter (RMS), and Silicon Valley communication production of SGT-11A and SGT-12B single and double jaw clamp type table, this kind of instrument with large diameter and small jaw electrical test resolution and high precision, accurate measurement, current flow the characteristics of. At the same time, the manual design of this kind of pliers is very suitable for the occasions with small space. Noise meter. The noise meter is mainly used to test the pulse component of rectifier equipment and DC converter output voltage, that is, noise voltage. At present, the noise meter in the market is mainly analog and digital. The analog noise meter is mainly JH5151 of state owned Jianhua instrument factory. Although it is larger and heavier, it has many testing indexes and high accuracy. Digital noise meter mainly has FZY-120 and FZY-120A, it has light and easy, portable, simple test, visual display and so on. At present, maintenance personnel can choose to use according to their favorite.
Q:How to use the correct measuring clamp current meter
1, in the high pressure loop measurement, prohibit the use of lead from the clamp ammeters another meter measurement. When measuring the phase current of high voltage cable, the distance between the cable head and line should be above 300mm, and the insulation is good, which can be carried out when the measurement is convenient. 2, the observation time, we must pay special attention to keep a safe distance from the head and charged part of the human body and any part of the charged body distance shall not be less than the entire length of the clamp meter. 3. When measuring low voltage fusible fuse or horizontally arranged low voltage bus current, each phase shall be protected or insulated by insulation materials, so as to avoid interphase short circuit4, the use of high voltage clamp current meter should be paid attention to when the voltage clamp current meter, prohibit the use of low voltage electric current clamp meter high voltage measurement circuit. With high voltage clamp meter measurement, by the two person operation, non duty measurement should fill in second working ticket, should wear gloves when measuring stand on the insulating mat, must not touch the other equipment, to prevent a short circuit or grounding.5, after the end of the clamp current meter to measure the switch to the maximum file, so that next time use careless flow; and should be kept in a dry room6, when the cable has a ground, it is strictly prohibited to measure. To prevent the breakdown of the ground due to the low insulation level of the cable head, and endanger personal safety.7, clamp meter measurement, near the wire current, also have influence on it, so must pay attention to the position of the wire to the equal phase.8, maintenance should not live operation, in case of electric shock.
Q:Automatic tripping of circuit breaker often, this is why, what to do?
After analyzing the two causes of circuit breaker tripping, some common analysis and treatment methods are summarized. The first is to judge whether it is a circuit problem or a circuit breaker problem. The general process is:Observe whether the burning of a circuit, whether there is odor, the low voltage cabinet within the two control loop whether there is no fault1., when there is a fault point, the switch can be closed, the line problem is explained, and the circuit breaker is irrelevant.2. there is no obvious fault point, in the case of no load, the circuit breaker still can not switch on, it shows that the circuit breaker can not be put into operation, it is the problem of the circuit breaker itself.
Q:Is the flow meter good or the multimeter?
The multimeter is also called the multiplex table, the multimeter, the three meter, the multiplication table and so on. It is an indispensable measuring instrument in the electric power and electronic departments. It is mainly used to measure the voltage, current and resistance.
Q:How to measure the static grounding resistance
The grounding resistance tester model is ZC29B. There are three lines: 20 meters of ground pile and 40 meter stake respectively
Q:How to accurately measure the Ma level current
Connect the ammeter to the circuit. To choose the right gear, unable to estimate the current range, from large to small range.
Q:How to measure the actual current of three-phase induction motor?
Available clamp type universal meter, but better according to the inverter panel display current adjustment is better, because the frequency of downtime is measured according to its own subject and tracking may have certain discrepancy
Q:20kW motor running for some time will trip what is the reason?
If you look carefully at this, I've met. Switch out the nasal line contact is not good, the heat to the air inside the trip. After tripping, you feel it immediately.
Q:The digital universal meter can measure the maximum AC current
Digital multimeter is generally the largest, can only measure 20A AC current, if you want to measure more current, you can use pliers type table.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range