KD series Slurry pump single shell

Ref Price:
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Product overview

KD series single shell slurry pump is a single-stage single-suction cantilever centrifugal pump, is my company according to the market demand, to comprehensively consider the working characteristics of the specific application system, to absorb the advantages of similar products at home and abroad, developed a new generation of slurry pump. This series of pump adopts excellent hydraulic model design, ensure the pump is more efficient, more reliable operation, longer life, the various performance indexes exceed industry standards, in the domestic leading level. KD pump completely subverts the traditional slurry pump double shell structure, adopt single shell design, make the pump structure more compact, lightweight maintenance more convenient.

Application field

The periphery of the flue gas desulfurization assistant system;

Alumina process mill;

Power plant ash metallurgical and chemical industry.

Product features

1, for the closed impeller impeller, high efficiency, wide flow design, anti-clogging, good resistance to cavitation performance.

2, vice impeller + packing combined seal, mechanical seal, seal packing seal three forms can be arbitrary choice.

3, single shell structure, small volume, light weight, easy to tear open outfit

4, the large capacity fuel tank design, prolong the service life of bearing

5, adopt the bracket, short cantilever, the large capacity fuel tank and the reasonable water cooling system design, thin oil lubrication oil bath, greatly extend the service life of the bearing, improves the whole machine trouble-free running time.

6, unique rotor axial regulating mechanism, is convenient to adjust the impeller, ensure the long-term stable operation of pump in the best condition

The working conditions

Flow range: Q = 5-3000 - m after/h; Lift range: H = 3-110 - m

Medium temperature: 80 ° C or less commonly, special of up to 110 ° C; Medium concentration: mortar concentration 45% or less, pulp density 60% or less

Mode of transmission: general for direct drive, also can be changed to other transmission way according to the requirements of customers




Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Which nuclear submarines use the shaftless pump technology?
At present, the submarine has been used in the pump jet technology, the most representative is the United States Virginia class submarine and the Russian North Sea God class submarines.. And shaftless pump is a derivative application of superconducting technology, which is more advanced than pump jet technology..If you want to learn more about shaftless pump technology, you can find relevant papers online.
Q:How do vacuum pumps and pumps work together?
The role of the check valve:"[the water pump impeller is not closed" refers to the pump suction pump before the water without water inlet pipe and water outlet pipe gas should be connected] is a connector, a connector, still can make the level surface, in order to prevent the water flow along the pipe, until it reaches the level of the flush, then increased check valve.
Q:Metering pumps related matters
Rotate to stroke length 100% position. This allows the kit to rotate to the back of the drain hole and align the bottom of the pump. Adjust the hydraulic end and diaphragm to the proper position during the pump operation.The duration of the pulse may not be long enough for the reaction time. With respect to the standard pulse width 80msec, the flow monitor pulse width expansion can be activated, increasing the pulse width to 300msec. Activate the smart switch, remove the cover fixed circuit board, remove the jumper X-1. This activates the extended function and allows more time before the failure instructions.Metering pump installed from the exhaust pump head, the use of self suction liquid imbibition. Keep the suction line as short as possible.
Q:Centrifugal pumps for normal operation, is it reasonable to install valves on their inlet lines?
Reasonable, no valve, how to debug, overhaulGenerally installed on imports of valves of relatively large Cv value
Q:Does the control cabinet of the fire control pump need to be related to the fire control room?
Normal words are needed, but when you check and check, has anyone checked?
Q:What is the function of a submersible pump?Do you have any knowledge about submersible pumps?.
Submersible pumpThe submersible pump is composed of a control cabinet, submersible cables, water pipes, submersible pumps and submersible motors.Submersible pump main application and scope of applicationIncluding mine rescue, construction, drainage, agricultural irrigation and drainage, industrial water recycling, urban and rural residents cited water supply, and even rescue, disaster relief and so on.Classification of submersible pumpsAs far as media is concerned, submersible pumps can be broadly divided into three categories: clean water submersible pumps, sewage submersible pumps, sea water submersible pumps (corrosive).
Q:What are the starting and stopping procedures for centrifugal pumps?
The use of centrifugal pump can be divided into three steps, namely, start, run, stop.Start: you should do the following preparation before starting:(1) check the water pump equipment in good condition.(2) the bearings are filled with oil, the oil level is normal, and the oil quality is qualified(3) all the inlet valves of the centrifugal pump are opened.(4) pump water injection or vacuum pump diversion (except for flow), open the vent valve exhaust.(5) check the leakage of shaft seal. It is advisable to fill the seal with a little drop of water.(6) the motor rotates in the right direction.
Q:Double floor sewage pump circuit diagram of a small problem
Question 3 when the water level is low, when the 1KA is connected, the pump will run depending on where your SS selector switch is located. Its left and right position, running pump and standby pump definition is different, left position is 1#, running 2# standby, right position is 2# running, 1# standby. Only inIn case the high level switch 2KA is connected, the standby pump may work at the same time.
Q:What is the dry running protector of screw pump? What's the principle and function? Thank you
The utility model relates to a screw pump dry running protector, which is used for protecting the stator and the rotor of the screw pump from being transported by air
Q:How long does the fine stone pump need maintenance? What should I pay attention to?
Check the line from the relief valve to the cylinder inlet to ensure that there is no external drainage or deformation due to impact and wear and that the connections are complete and fully tightened. - replace any damaged pipe immediately. - change the original settings strictly: all adjustments and calibrations can only be done by professionals. - no fucks hydraulic components, otherwise manufacturers on product warranties and liability shall not be responsible for. A warning because the hydraulic oil can reach very high temperature, there is the danger of burns, so open pipe fittings should take appropriate protective measures. Any replacement parts must conform to the level specified by the manufacturer. 8.2 check lubrication grease pump in oil at any time to ensure adequate and clean the lubrication pipeline joints without overflow phenomenon. Check the lubrication of the running parts at any time, and find the parts which lack oil, and check them immediately to prevent accidents. - check that the centralized lubrication system is effective daily. When the grease pump is empty, the grease added is often not easy to pump out because of the bubble. In this case, open the outlet of the pump, run the grease pump until the grease is re flowing, and then connect the pipe

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range