1.Structure of  Water Pump with Diesel Engine Description

Fire Fighting Water Pump casing is axially split, which permits removal of the complete rotor without moving either piping or motor. Pumps generating high heads have double volutes to reduce radial forces. Replaceable wear rings protect the casing at the impeller running clearances. Flange drilled to ISO, DIN, BS or ANSI.The close double suction impeller gives practically zero axial forces. Each impeller is statically and dynamically balanced according to NFPA 20 STANDARD .Vertical or horizontal, soft packing or mechanical seal, grease or oil lubrication bearing on request. NFPA 20 standard pump is available.

 

2.Main Features of the Water Pump with Diesel Engine

•Diesel pump unit: diesel engine, water pump, cooling fan, cooling water tank, steel structure base (including fuel tank 80-120L), battery, connecting wires, exhaust muffler, control panel. 
•Standard design is the pump group, the fuel tank, control panel, battery composite type. 
•Can be designed according to customer requirement pump group, the fuel tank, control panel, battery, outdoor rainproof cabinet composite outdoor type. 
•Can be designed according to customer requirement trailer (four or two wheels) moveable type. 

3.Water Pump with Diesel Engine  images

Centrifugal Water Pump with Diesel Engine for Irrigation

4.Water Pump with Diesel Engine Specification

 

Pump TypeSplit Casing Pump
Casing MaterialHT200
ImpellerSS304,SS316,Copper,HT200
Pump SealingPacking seal,Mechanical seal
Capacity Range126m3/h~8520m3/h
Head Range8m~140m
Inlet/Outlet diameter6"(150mm)~32"(800mm)
Rotary Speed1450rmp/2950rpm/585rpm/730rpm/970rpm
NPSH(r)2.5m~7.5m
N.weight165kgs~2550kgs
Pump Parts

Casing,Pump cover,Impeller,Shaft, Double suction sealing ring

Shaft sleeve,Bearing etc

Certificate

ISO9001:2008,CE,TUV

 

 

5.FAQ

What is your product range?

Centrifugal pump, slurry pump, gravel pump, clean water pump, sewage pump, chemical pump, single stage

pump, double suction pump, industry pump, oil pump, paper pulp pump, mud pump, self-priming pump, pipe

water pump, boiler water pump, etc.

Are you a manufacturer?

Yes, we have been in manufacturing and marketing industry centrifugal pump over 20 years.

What information should I let you know if I want to get a quotation?

Pump capacity, pump head, medium, medium temperature, pump material, quantity, if possible, please also

provide the pump model you are using now, price will be calculated as per the pump model, if not, we willrecommend relevant product for reference.

 

Q:When the water pump is started, why should it start when the outlet valve is closed? Thank you
The valve opening pump is aimed at the centrifugal pump.From the power curve of the centrifugal pump, the power of the centrifugal pump increases with the increase of the flow rate; the flow curve of the centrifugal pump shows that the flow rate of the centrifugal pump decreases with the increase of the head.
Q:Piston filling and peristaltic pump filling which precision is high?
If the unit area is large, the accuracy of the plunger is certainly not high. The peristaltic pump is used by means of extrusion roller extrusion pump to promote the solution, this also depends on the unit cross section size, the same motor accuracy is very important.
Q:A residential building with a floor height of 11 stories and a roof height of 33 meters. The height of the water tank is 37.7 meters. The basement is -3.3 meters, only set fire hydrant, fire pump only consider the indoor fire water, fire flow should be 10l/s. Now select a fire pump, concrete should be much traffic, big head, flow determine how? How to determine the head, I hope to say some more detailed, thank you, and there is to explain this question, why is the fire pump lift 120?. Thank you
According to the water quantity form fire flow water supply system fire safety in high-rise building fire hydrant pump lift is 10L/s, accurate algorithm is to say after a simple calculation with each indoor hydrant flow is two 5L/s bolt so to get the most unfavorable point for the calculation unit to calculate the minimum requirements, with the most unfavorable point suppository pressure specifications 0.07MPa, partial loss of the most unfavorable line and the line (according to the equivalent length) and loss (according to the material resistance coefficient), and finally the pump head loss of gravity difference. But we just calculate the construction elevation difference multiplied by 110% to 120% to determine the head {there is a need to know is: conversion head (m), (kg) and MPa kg 1MPa=10 kg = 100m is the vertical water column on unit area pressure conversion
Q:What does electromechanical vector pump mean?
Scope of application is;Residents living water: such as high-rise buildings, residential areas, villas and so onPublic places such as hospitals, schools, gymnasiums, golf courses, airports, etc
Q:Centrifugal pump flow, why can be adjusted through the outlet valve? Can the flow of the reciprocating pump be adjusted in the same way?. Why
First of all, we know that pump according to the principle of work is divided into speed and volume type, centrifugal pumps are speed type, and reciprocating pumps are volume type.The centrifugal pump can adjust the flow through the outlet valve and outlet valve opening can determine the pump flow and head performance curve parameters such as specific relationship between the outlet flow and pressure can be provided by the data pump manufacturers endplate that even close the outlet valve of the pump pressure will also have a fixed value, but not allow zero flow pump operation, vibration caused by damage to the pump on the mechanical seal is not good and so easy to cavitation, set the minimum reflux line.
Q:What is the minimum continuous flow of a pump?
The minimum continuous steady flow can be obtained by test and, in general, the pump supplier will indicate(2) minimum continuous heat limited flow (.API) provides minimum continuous heat limit flow, which means the minimum continuous flow that the pump can maintain and that its operation is not impaired by the temperature rise of the liquid being pumpedMinimum continuous heat limited flow can be calculatedIn the formula, the Pe amount of the fixed axis power is.KW;P pump medium density, kg / m3;
Q:Why can't the inlet of centrifugal pump be negative pressure?
The entrance can be a negative pressure. You can often see someone pumping water from the pool. How can you pump water if it is not negative pressure?
Q:Please give me professionals to calculate, the cylinder bore is 100 and the rate of 20m/s, the leakage can be ignored, but to the large flow pump!
Select the hydraulic pump from the following considerations:1. hydraulic pump pressureHydraulic pump operating pressure is the pump (or motor) in actual work output (or input) oil pressure, determined by the external load.Rated pressure refers to the maximum pressure under continuous running in accordance with the test standards under normal working conditions. The size of the pump is limited by the service life, and the service life of the pump (or motor) will be shorter than the design life if it exceeds the rated pressure. When the work pressure is greater than the rated pressure, it is called overload.
Q:What are the meanings of the vacuum pump, the front pump and the main pump?
The main pump can be understood as a booster pump, used to improve the vacuum mechanical pump with pumping quantity. As the roots pump, diffusion pumps, molecular pump. These can not use (too much pressure) so the need for mechanical pump drainage, the vacuum chamber is pumped into the rough vacuum, then the main pump starts to work.
Q:What are the advantages and disadvantages of the pump control system and valve control system in the hydraulic system? How to choose in the project?
Valve control system is generally used for open systems, through the proportional valve or servo valve flow changes to control the motor or cylinder actuator action. The advantages of the system are energy saving, heat generation, and control accuracy. The disadvantage is that the system is complex and the cost is higher.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords