sanitary pipe clamp fittings fittings

Ref Price:
$0.03 / pc
Loading Port:
Qingdao
Payment Terms:
TT LC
Min Order Qty:
100 pcs pc
Supply Capability:
300000pcs Per Month pc/month
Inquire Now Customer Service

Contact us by

(1) WeChat
(2) Whatsapp: +8617190086776

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Usage: Pipe Clamp
Material: steel、matel;Galvanized iron ,stainles
Band width:3mm/20mm
Connection:welding
Model number:As your requirement
Structure:Swivel clamp
Certificate:ISO9001:2008
Feature:
1.Use the open internal and external circle structure,and with screw fixed.It is effectively to solve the problem that when small diameter solft tube connect the hared tube,it is easy appear dead angle,and liquid or gas leakage problem.Easy structure,Easy maked.
2.Edge is no burrfree,it is ability to prevent the tube damaged
3.By a efficiently hydrogen relief treatment,long-term use needn't to worry fracture and other problems
Surface: zinc plated Packaging
4.Accord with DIN3017 Standard.By 48 hours salt and fog test,it has a good corrosion resistance
5.By our last 48 hours elastic test,to insure a high strength mechanical properties.
6.Easy to fix.
Working Temp: -40 ℃ ~ 110 ℃
Size:3/8" 1/2" 3/4" 1" 1 1/4" 1 1/2" 2" 2 1/2
Structure: Suspension Clamp and so on On-time shipment and pre-shipment product quality safeguards clamp is mainly used in automobiles,tractors, ships, gasoline engine, and so on each kind of mechanical
device for oil, gas, hydraulic hose connector, various types of
rubber tube interface must join parts fastening.
Detail: plywood case ,pallets or any other package as buyer's requirements
Delivery Detail: about 20-30days

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:The multimeter, megohmmeters and use clamp meter.
Preparation prior to use1, check whether the European watch can work properly, place the watch horizontally, and empty the handle of the euro watch. The pointer should point to. O, and then slowly shake the handle, so that L and E two terminal pile output line instantaneous short, the pointer should quickly point to zero. Note that the L and E cannot be shorted too long when shaking the handle, otherwise it will damage the watch. ,2, check the electrical equipment and circuit being tested to see if all the power has been cut off. Never allow equipment and lines to be charged with a European watch.3, before measuring, deal with equipment and line the first discharge capacitor discharge equipment or line so as not to endanger the personal safety and damage megohmmeters, it can reduce the measurement error at the same time, attention will be the test point to wipe clean.
Q:Clamp meter cable direction? Why do I change the direction of measurement with a cable, the current is not the same
There is no direction in the clamp table and the card line. This is what you said
Q:How to maintain and maintain the communication and power room?
AC / DC clamp type meter. AC / DC clamp meter as the daily maintenance work is one of the essential test tool, mainly used to test the voltage, current, frequency and other related parameters, it has high resolution and precision testing and more testing function. At present, the maintenance personnel usually use the FLUKE of the United States F337 AC / DC Clamp Meter (RMS), and Silicon Valley communication production of SGT-11A and SGT-12B single and double jaw clamp type table, this kind of instrument with large diameter and small jaw electrical test resolution and high precision, accurate measurement, current flow the characteristics of. At the same time, the manual design of this kind of pliers is very suitable for the occasions with small space. Noise meter. The noise meter is mainly used to test the pulse component of rectifier equipment and DC converter output voltage, that is, noise voltage. At present, the noise meter in the market is mainly analog and digital. The analog noise meter is mainly JH5151 of state owned Jianhua instrument factory. Although it is larger and heavier, it has many testing indexes and high accuracy. Digital noise meter mainly has FZY-120 and FZY-120A, it has light and easy, portable, simple test, visual display and so on. At present, maintenance personnel can choose to use according to their favorite.
Q:What is the connection between the distribution box and the bridge?
May and the use of electric welding machine, wire welding machine in which a random metal pipe, when welding welding current welding wire through a plurality of left back, in a weak point there will be a great current, have a fever.
Q:How to accurately measure the Ma level current
Connect the ammeter to the circuit. To choose the right gear, unable to estimate the current range, from large to small range.
Q:How to measure the current and voltage clamp meter?
(1) in the measuring line, to clamp meter data of zero, to prevent errors in subsequent measurement.(2) after determining the voltage of the line to be measured, select the appropriate range.
Q:The difference between digital multimeter and caliper type multimeter
The principle of clamp meter is the use of electromagnetic induction principle, core wire clamp measurement will require the clamp meter of silicon steel lamination edges, then the wire clamp is equivalent to a coil current transformer, belonging to a current through the coil, when will dinner two coil clamp type ammeter inside induction two current, current in the wire clamp type ammeter dial can read the measurements.
Q:Would you please tell me how to use the DM6266 clamp type table with 261 insulation tester?
Greater than 20K ohm, cannot be measured; 266 or 6266; this model has no measuring range greater than 20K;
Q:Generator carbon brush fire how to deal with?
Carbon brush and slip ring should be inspected every day. Main inspection items are:(1) the wear length of carbon brush should not exceed 2/3. When the wear length of the carbon brush exceeds the 2/3 (i.e. the top of the carbon brush is at the same level as the top of the brush holder), it must be replaced.(2) carbon brush without sparking. When the carbon brush starts to spark, you must find out the reason and remove it in time.(3) there is no offset slip ring outside the carbon brush, and the edge of the carbon brush is not cracked.(4) the brush brush is connected with brush holder and carbon brush, without heating and touching brush holder.(5) the carbon brush has no pulsation, shaking or sticking in the brush holder.(6) regularly measure the current of each carbon brush evenly with the DC clamp type meter, and measure the carbon brush with the infrared thermometer. If abnormal, it should be replaced in time.(7) the spring pressure is normal, without deformation and fracture. Normal, the pressure on each carbon brush should be uniform and stable, the unit pressure is usually between 1.1kg ~ 2.5kg, the uneven pressure difference between the carbon brush should be less than 5%.(8) the distance between the brush holder and the slip ring conforms to the specified value. Distance between brush holder and slip ring of generator: 2.5 ~ 3 mm, distance between main brush holder and slip ring: 2~4 mm.
Q:A fire was found with a ground electricity? Stealing electricity.
To do so is very dangerous, prone to accidents, in case the public grounding wire grounding resistance is large, it will cause the water running electricity, indirectly causing electrocution, death accident, that would be troublesome

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range
客服
live chat