• klikkon brass quick release pipe clamps System 1
  • klikkon brass quick release pipe clamps System 2
klikkon brass quick release pipe clamps

klikkon brass quick release pipe clamps

Ref Price:
$0.03 / pc get latest price
Loading Port:
Qingdao
Payment Terms:
TT LC
Min Order Qty:
100 pcs pc
Supply Capability:
300000pcs Per Month pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing
Usage: Pipe Clamp
Material: steel、matel;Galvanized iron ,stainles
Band width:3mm/20mm
Connection:welding
Model number:As your requirement
Structure:Swivel clamp
Certificate:ISO9001:2008
Feature:
1.Use the open internal and external circle structure,and with screw fixed.It is effectively to solve the problem that when small diameter solft tube connect the hared tube,it is easy appear dead angle,and liquid or gas leakage problem.Easy structure,Easy maked.
2.Edge is no burrfree,it is ability to prevent the tube damaged
3.By a efficiently hydrogen relief treatment,long-term use needn't to worry fracture and other problems
Surface: zinc plated Packaging
4.Accord with DIN3017 Standard.By 48 hours salt and fog test,it has a good corrosion resistance
5.By our last 48 hours elastic test,to insure a high strength mechanical properties.
6.Easy to fix.
Working Temp: -40 ℃ ~ 110 ℃
Size:3/8" 1/2" 3/4" 1" 1 1/4" 1 1/2" 2" 2 1/2
Structure: Suspension Clamp and so on On-time shipment and pre-shipment product quality safeguards clamp is mainly used in automobiles,tractors, ships, gasoline engine, and so on each kind of mechanical
device for oil, gas, hydraulic hose connector, various types of
rubber tube interface must join parts fastening.
Detail: plywood case ,pallets or any other package as buyer's requirements
Delivery Detail: about 20-30days
Q:How to find out the broken capacitor in the three-phase capacitor of the reactive compensation cabinet with the clamp table?
Electrical operation rules specified in the current method for measuring power capacitor should be removed after online with the corresponding voltage level of the shaking table measuring attention before measuring the discharge if there is damage to the capacitor must immediately remove power treatment to prevent explosion harms people body and equipment safety of capacitor fault.
Q:Why my fridge had put popsicle or ice cream frozen stiff
If the refrigerator is refrigerant, first to the refrigerator, control in the freezer, will appear, you said the freezing is not hard (folded below the melting). The temperature in the freezer is on the high side. The temperature in the refrigerator can meet the requirement. (it was designed at the factory.)
Q:How can I measure the voltage and current with a clamp?
Clamp meter with digital display and pointer display, measuring about estimated range of the measured current, pay attention to the selection of range clamp meter, try to choose the appropriate range to reduce the error. In addition to the wire clamp in the middle of the jaw clamp meter, if the measured current is too small, can take the form of a plurality of winding wires, and then measure the value by the number of roots, but also take care not to measure the bare wire, so as to avoid the risk of electric shock. If we can measure the voltage clamp and other functions of the table, when measuring the current to pull out test. Furthermore, in the three-phase load, the line of the jaw clamp measures the current of the wire, and the two measuring current is the third. When measuring the current voltage clamp meter should note 1, the measured line is lower than the rated voltage of the current clamp meter; 2, measurement of high voltage transmission lines, to wear insulated gloves, wear insulated shoes, stood on the insulating pad; 3, to close not charged for jaw closing range; 4, in the measurement of resistance before the tested circuit must be completely discharged, and completely isolated from the power supply circuit; 5, if the test pen or power adapter to replace the damaged power, must have the same model and the same electrical specification test pen and power adapter; 6, the electric energy consumption as the battery indicator instructions, do not use instruments. If you don't use it for long time, remove the battery after storage; 7, not in high temperature, high humidity, flammable and explosive and electromagnetic field to store or use clamp meter; 8, please use a damp cloth or cleaner clamp meter shell, do not use friction or solvent; 9, the instrument when wet please, drying and storage.
Q:How to measure the motor current with a multimeter?
Measurement of direct current. The first black probe into "COM" hole. If the measured current is more than 200mA, will be the red pen into the "10A" Jack and the knob to direct "10A"; if the current measurement is less than 200mA, the red pen into the "200mA" Jack will knob to the appropriate range of DC within 200mA. When adjusted, it can be measured. String the multimeter into the circuit and keep it steady until you read it. If the display is "1.", then to increase the range; if the numerical left "-" appears, indicates that the current from flowing into the black pen multimeter.
Q:The power consumption of the same load, different power motors?
The key lies in the size of the load, according to the current data you provide, basically can determine whether the motor is loaded; if the motor using 37kW, because the load torque constant, the motor for rated torque, it is necessary to reduce speed, increasing the current, the current may be not reached before 70A would have burned the motor.
Q:30mA leakage breaker trip home is always with what method to find the leakage point, with clamp ammeters how?
Check the leakage with shaking table or pointer multimeter 10K resistor file. In the case of power failure, the insulation resistance between the fire line and the ground wire of each branch is measured. When there is leakage, the meter will indicate a relatively small resistance value and the insulation will indicate infinity.
Q:But after 3 minutes on the machine, there is no electricity, what's the matter?
First of all, I suggest you make sure the compressor has no work and listen to the sound. No words starting with his hand to open the machine shell surface of compressor, see is not hot, hot water is available as the compressor cooling after the boot, if opened, let him run for a period of time, or if that is automatically shut down the compressor overheating protection. There are many conditions that cause overheating protection. The main points are normal and abnormal. Normal is when the air conditioning works in very harsh conditions, such as very high ambient temperature, refrigeration, and press load is too large to protect. Non normal, mainly the system problems, such as Freon shortage, the pipeline blocked, the fan does not turn, and so on, according to the specific circumstances of the decision.
Q:A selection table clamp type table
1, before use, should read the instruction manual carefully, make clear whether it is communication or AC and DC dual-use.2, the measured voltage clamp meter shall not exceed the values marked on the ground, otherwise easy to cause the accident, or cause the risk of electric shock.3, you can only measure the current one conductor, the measured wire clamp should be placed in the center of the window, the window with all phase conductors can not measure.
Q:How to use the multimeter to check the grounding wire is normal?
The multimeter is not able to detect whether the earth wire is normal. Grounding resistance detection is usually done by bridge method, grounding resistance tester and clamp type meter grounding resistance tester. They all need special test equipment.
Q:Automatic tripping of circuit breaker often, this is why, what to do?
Generally speaking, there are two main causes of circuit breaker tripping. The first is short circuit. Similar conditions occur in a humid environment. Remember a customer reflects a DW16-2500 universal circuit breaker, sunny normal, rainy days often trip, that is caused by short-circuit. The final check is due to the short circuit of the control circuit, resulting in two line burn, resulting in tripping.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords