klikkon brass quick release pipe clamps

Ref Price:
$0.03 / pc
Loading Port:
Qingdao
Payment Terms:
TT LC
Min Order Qty:
100 pcs pc
Supply Capability:
300000pcs Per Month pc/month
Inquire Now Customer Service

Contact us by

(1) WeChat
(2) Whatsapp: +8617190086776

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Usage: Pipe Clamp
Material: steel、matel;Galvanized iron ,stainles
Band width:3mm/20mm
Connection:welding
Model number:As your requirement
Structure:Swivel clamp
Certificate:ISO9001:2008
Feature:
1.Use the open internal and external circle structure,and with screw fixed.It is effectively to solve the problem that when small diameter solft tube connect the hared tube,it is easy appear dead angle,and liquid or gas leakage problem.Easy structure,Easy maked.
2.Edge is no burrfree,it is ability to prevent the tube damaged
3.By a efficiently hydrogen relief treatment,long-term use needn't to worry fracture and other problems
Surface: zinc plated Packaging
4.Accord with DIN3017 Standard.By 48 hours salt and fog test,it has a good corrosion resistance
5.By our last 48 hours elastic test,to insure a high strength mechanical properties.
6.Easy to fix.
Working Temp: -40 ℃ ~ 110 ℃
Size:3/8" 1/2" 3/4" 1" 1 1/4" 1 1/2" 2" 2 1/2
Structure: Suspension Clamp and so on On-time shipment and pre-shipment product quality safeguards clamp is mainly used in automobiles,tractors, ships, gasoline engine, and so on each kind of mechanical
device for oil, gas, hydraulic hose connector, various types of
rubber tube interface must join parts fastening.
Detail: plywood case ,pallets or any other package as buyer's requirements
Delivery Detail: about 20-30days

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:How can I measure the voltage and current with a clamp?
Clamp meter with digital display and pointer display, measuring about estimated range of the measured current, pay attention to the selection of range clamp meter, try to choose the appropriate range to reduce the error. In addition to the wire clamp in the middle of the jaw clamp meter, if the measured current is too small, can take the form of a plurality of winding wires, and then measure the value by the number of roots, but also take care not to measure the bare wire, so as to avoid the risk of electric shock. If we can measure the voltage clamp and other functions of the table, when measuring the current to pull out test. Furthermore, in the three-phase load, the line of the jaw clamp measures the current of the wire, and the two measuring current is the third. When measuring the current voltage clamp meter should note 1, the measured line is lower than the rated voltage of the current clamp meter; 2, measurement of high voltage transmission lines, to wear insulated gloves, wear insulated shoes, stood on the insulating pad; 3, to close not charged for jaw closing range; 4, in the measurement of resistance before the tested circuit must be completely discharged, and completely isolated from the power supply circuit; 5, if the test pen or power adapter to replace the damaged power, must have the same model and the same electrical specification test pen and power adapter; 6, the electric energy consumption as the battery indicator instructions, do not use instruments. If you don't use it for long time, remove the battery after storage; 7, not in high temperature, high humidity, flammable and explosive and electromagnetic field to store or use clamp meter; 8, please use a damp cloth or cleaner clamp meter shell, do not use friction or solvent; 9, the instrument when wet please, drying and storage.
Q:What's the reason for the leak on the air conditioner? The pipes outside are changed, but the air conditioner is nearby
Sometimes the ventilation pipe air conditioning installation company installed in place, the connection is not smooth, the vent seal will cause the air outlet panel dewing phenomenon. Of course, the central air conditioning outlet drip water, mostly by the first two reasons.
Q:How to use the caliper and its working principle?
A part of the measuring ammeter million is determined by the current transformer and current measuring part composed of 000 table. The iron core of the mutual inductor is provided with a movable part and is connected with the handle. When the utility model is used, the movable iron core is opened by pressing the handle. The wires of the current to be measured are put into the jaw and the handle is closed to close the iron core. At this point, the current through the wire is equivalent to the transformer primary winding, the two winding will appear induction current, the size of the wire by the working current and winding coil ratio is determined. The ammeter is connected to both ends of the two winding, so that the current indicated by it is the current in the two winding, which is proportional to the current in the work. So will be good as the amount of current reflect a scale on the side of the wire when a current is passed, and the two winding connected to the ammeter pointer is in proportion to deflect, thus indicating the value of measured current.
Q:But after 3 minutes on the machine, there is no electricity, what's the matter?
First of all, I suggest you make sure the compressor has no work and listen to the sound. No words starting with his hand to open the machine shell surface of compressor, see is not hot, hot water is available as the compressor cooling after the boot, if opened, let him run for a period of time, or if that is automatically shut down the compressor overheating protection. There are many conditions that cause overheating protection. The main points are normal and abnormal. Normal is when the air conditioning works in very harsh conditions, such as very high ambient temperature, refrigeration, and press load is too large to protect. Non normal, mainly the system problems, such as Freon shortage, the pipeline blocked, the fan does not turn, and so on, according to the specific circumstances of the decision.
Q:Air conditioning suddenly does not cool down, what's the matter?
Two reasons for the non cooling of air conditioning: the voltage of power supply is not enough: the solution is to maintain normal supply voltage.
Q:How to distinguish stealing from electricity
No problem has been found. The meter will be removed and sent to the measuring and testing department for verification. Usually, the meter should be sealed and mounted on the table inside the box meter relatively safe.
Q:What is the connection between the distribution box and the bridge?
To zn76126 fourteen class teacher said, with a wire clamp meter card in power when there is no current. If there is no, it can be proved that the electric wire zoom is transient. If there is a current to turn off the power of the box one by one to see if the current is reduced, the circuit of this box will be excluded. Look at the wiring of other distribution boxes.
Q:Can the clamp meter measure the direct current?
Uni-t has clamp meter can measure direct current.
Q:Use clamp meter?
The use of AC clamp meter measurement can only clamp into a wire, can not clamp into two or more wires.
Q:Clamp ammeters how to measure resistance, current, voltage
Usage:Although the clamp meter is similar, but each kind of table usage due to the design of the use of different methods are also different, so the user must read the instructions carefully before use.To be on the safe side, here are the main methods, but still want to read the manual. To measure the voltage and the resistance and the basic multimeter, using the pen pen insertion holes

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range