Specifications
1. Heat Insulation & Energy-Saving
2. Seisimic-Resistance & Light Weight
3. Sound-Proof & Water proof
4.beautiful designs
stone wall panel polyurethane Project Details :
Product Name.: | facade panel |
HS Code: | 73089000 |
Material: | Hanyi Panel is made up of three layers: the top material is embossed metal board coated with Alu-zinc, the middle is fire-safe material and Polyurethane foaming and the back is glass fibre paper |
Feature: | Decoration, insulation, energy-saving, fire-safe , easy installation, etc. |
Application: | Hanyi Decorative Wall Panel could be used on any structural buildings : brick wall, steel structure, cement wall,, wood wall etc for decoration and insulation . |
Weight.: | 3.7kg/ m2 |
Panel Size: | Length :3000-6000mm(standard length is 3800mm) width: 380mm, thickness : 16mm |
Packing Size: | 3840*415*135mm |
Package quantity: | 8 pcs/carton |
Productivity: | 3000m2/ day |
Delivery period: | 3-7days |
Minimum Order: | 1000m2 ( 300m2 for one color ) |
Unit Price: | USD14-18/ Square Meter |
Shipment Terms: | FOB CRF CIF etc |
Payment Terms: | L/C, T/T |
Export Markets: | Middle East, Europe , South America ,Asia etc. |
Certificate : | CE, ISO9001:2008 , Gost R certification and Russia Fire-safe certification |
Feature:
Light weight, high strength, impact resistance, heat insulation, fire resistance, anti-seismic, elegant pattern design, single or double colors, durable, weather resistance, easy to install.
- Q:What is the curtain wall insulation profile
- Curtain wall insulation profiles are generally used for the curtain wall, there are two kinds of plastic injection and wear, wear more common, that is, between the two ordinary aluminum profiles with two pieces of nylon material as a whole, nylon can transmit force But also can cut off the indoor and outdoor heat conduction, to achieve the purpose of energy conservation
- Q:Outer frame glass curtain wall 120 profile thickness requirements
- Column not less than 3 thick, beams not less than 2 thick, span greater than 1200 not less than 2.5 thick
- Q:Full concealed glass curtain wall works, aluminum alloy column theoretical weight Column is 120 * 60 aluminum alloy beam is 60 * 60, the material is 6063-T5, the drawings do not have the standard thickness, the theoretical weight is how much,
- This problem I encountered, you get the drawings also need to deepen the design, especially the aluminum alloy profiles, depends on what brand you and what series, each brand will have its own profile, such as 120 profiles, cross-section will There are many forms of your company to choose, different cross-section manufacturers will give the weight of the profile is how much, so you will be accurate, this is not like a steel weight of the theoretical weight, the current curtain wall profiles more , Each have electronic or paper profiles, if you are the construction unit, of course, to choose to meet the original requirements of the drawings and the lightest weight of the profile
- Q:Main wall thickness requirements greater than 1.4mm What is the meaning, as well as curtain wall.
- Live wall thickness requirements of more than 1.4mm refers to the doors and windows system, in the doors and windows norms require high-rise building doors and windows wall thickness of not less than 1.4mm, low wall thickness of not less than 1.2mm, but now 1.2mm wall thickness The building is getting higher and higher is slowly exit, the general profile manufacturers to provide the wall thickness of more than 1.4mm.
- Q:Glass curtain wall skeleton need what material
- Glass curtain wall skeleton requires material: 1, the skeleton: the main skeleton of the various profiles, as well as connecting and fixed a variety of connectors, fasteners. 2, profiles are: angle steel, square steel, channel and aluminum alloy profiles. 3, fasteners are: expansion bolts, aluminum nails, nails, connecting parts to use angle steel, channel steel, steel processing from. 4, aluminum alloy profiles should be refined aluminum alloy profiles, and in line with GB5237 standard requirements. Aluminum alloy oxide film is not lower than AA15 level. Aluminum alloy bar section section of the force part of the wall thickness should not be less than 3mm. Glass curtain wall aluminum alloy materials are used according to the need to make a variety of complex geometric shape of the profile, the alloy composition and mechanical properties should have the manufacturer's certificate. The surface of the profile is either anodized or plated.
- Q:150 profile curtain wall price of 680 yuan how much profit
- This depends on the thickness of the profile, the specifications of the glass model, and the processing technology.
- Q:Curtain wall aluminum is not broken bridge aluminum line okay
- Hidden curtain wall itself is the heat, the box wall is the existence of broken bridge insulation!
- Q:Can the broken aluminum frame be used for curtain walls?
- Have not heard of hidden curtain wall insulation profiles, hidden curtain wall without exposed metal components, indoor and outdoor heat itself can not be directly through the heat transfer of metal to exchange, so do not have to use insulation bars.
- Q:Glass curtain wall aluminum frame with what role
- Aluminum alloy itself has both a skeleton structure and a fixed glass
- Q:The drawings change from 150 series to 180 series, and now accounts are controversial because of the difference of this content. What should I do this? What is the basis for it?
- First: you want to see how much you use the profile of the weight of rice (including columns, beams, sub-box, and so on small accessories) Second: the column and the beam is the distance between the number Third: select the surface calculation as much as possible to choose the same sub-grid If each face of the sub-grid gap is not large, then each side are considered one by one or take the grid in the face to count.
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Facade Wall Cladding(Facade Panel Exterior Wall Panel Professional Maufacturer)
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products
Related keywords