Description Of CE Approve
d 90KW Inverter Frequency
Features Of CE Approved 90KW Inverter Frequency
1).Adopts 16 bit microprocessor, sine wave PWM control2).Automatic torque ascension and automatic sliding compensation function
3).Output frequency 0.1-400 Hz
4).8 period of speed setting and 7 period can be running the program
5).Low noise, carrier frequency can from 1 kHz-15 kHz adjustment
6).Two paragraphs Acceleration and deceleration time and two segments of the S Curve slow and deceleration
7).Simulation frequency set acceptable 0-10 VDC, 4-20 mA
8).The built-in serial communication interface RS-485(baud rate can reach 38400)
9).Save energy running and automatic voltage stabilizing section function (AVR)
10).Adjustable V/F curve Acceleration and automatic and deceleration function
11).Simple vector control and built-in PID control, and the simple positioning function
12).Sleep/wake up function and zero velocity keep function
Structure Of CE Approved 90KW Inverter Frequency
Application Of CE Approved 90KW Inverter Frequency
★Textile: coarse spinner, spinning frame, wrap-knitting machine, loom, knitting machine, silk-spinning machine, etc.★Plastic: extruder, hauling machine, decorating machine, etc.
★Pharmacy: mixer, roaster, etc.
★Woodworking: engraving machine, sander, veneer peeling lathe, etc.
★Papermaking: single type papermaking machine, etc.
★Machine tool: non-core grinding machine, optical lens grinding machine, cutting mill, etc.
★Printing: cloth-washing machine, dye vat, etc.
★Cement: feeder, air blower, rotary furnace, mixer, crusher, etc
★Fan and pump: kinds of fans, blowers and pumps
Performance Of CE Approved 90KW Inverter Frequency
Item | Specification | |||||||
Input | Rated voltage | T4 series: Three phase 380v, ±15% | ||||||
Frequency | S/T2 series: Three/single phase 220V, ±15% | |||||||
50/60Hz ±5% | ||||||||
Output | Voltage | T4 series: Three phase 0-380V | ||||||
Frequency | S/T2 series: Three phase 0~220v | |||||||
0-400Hz | ||||||||
Overload ability | 150% rated current for 30s; 180% rated current for 1s; | |||||||
Dissipation | Cooling type | Forced Cooling | ||||||
Temperature protection | Heatsink temperature >85℃ trip protection against overheat | |||||||
Fan control | Heatsink temperature> 50℃, fan forced operation, frequency inverter continue work | |||||||
Control | Control mode | Open-loop vector control, V/F control | ||||||
Performance | Start torque | Open-loop vector control: 0.5Hz 180%; | ||||||
VF control: 0.5Hz 150% | ||||||||
Speed range | Open-loop vector control:1:150; | |||||||
VF control:1:100 | ||||||||
Speed control precision | Open-loop vector control: ±0.2%; | |||||||
VF control:±0.5% | ||||||||
Function | Channel of operation command | Keyboard control,terminal control,communication control | ||||||
Start mode | Direct start, DC injection braking before start, speed tracking before start | |||||||
DC injection braking | Start DC injection braking, stop DC injection braking | |||||||
Dynamic braking | Built-in braking unit | |||||||
Frequency source choice | Keyboard digital frequency setting, analog AVI setting | |||||||
PID control setting, telecommunications setting | ||||||||
Frequency resolution | Keypad setting:0.01Hz; Analog setting: 0.1% | |||||||
Carrier frequency | 1Khz~12Khz, | |||||||
Acc/Dec time | 0.1~6000.0s or 0.01~600.00s | |||||||
Signal | Analog input | AVI:0~10V | ||||||
ACI:4~20mA | ||||||||
Keyboard potentiometer input: 0~10V | ||||||||
Analog output | AFM:0~10V or 0~20mA, Select through JP1 jumper | |||||||
Digital input | A total of 28 kinds of function could be selected from S0 ~S5. | |||||||
Digital output | 1 channel open collector output(MO1-MCM) | |||||||
1 channel relay output( TA-TC normally open, TB-TC normally closed; | ||||||||
Communication Port | Communication protocol | Based on RS485 hardware, support standard MODBUS protocol. | ||||||
Display Functions | Four digital tube display | Can monitor the operation state of frequency inverter flexibly and conveniently. | ||||||
Installation | Humidity | Less than 90%RH | ||||||
condensation | ||||||||
Vibration | Less than0.6G | |||||||
Elevation | 0~1000m, reduce the rated specification 10% when lift 1000m for each. | |||||||
Storage temperature | -20~60℃ | |||||||
Structure | Defend degree | IP20 |
- Q: Can the laptop's power adapter be used for years?
- Generally 3 to 5 years is not a problem, good quality can be used for 10 years. Power adapter is a small portable electronic equipment and electrical and electronic power supply conversion equipment, generally by the shell, power transformer and rectifier circuit, according to its output type can be divided into AC output and DC output type; by way of connection Divided into wall and desktop. Extensive support in the phone son machine, game consoles, language repeaters, Walkman, notebook computers, cellular phones and other equipment.
- Q: What is the motor series parameter setting of the inverter? If it is with the spindle,
- Ordinary inverter standard drive is a 4-pole motor, the greater the number of poles of the motor, the greater the rated current, the motor pole number is the frequency converter when the self-learning automatically set, in the vector control must be self-learning
- Q: Inverter signal line analog 4-20mA connection positive and negative can be reversed?
- Inverter signal line analog 4-20mA connection when the positive and negative is not reversed. Inverter input analog signal is generally 4-20mA, 0-20mA, 0-5V, 0-10V and so on.
- Q: Is the inverter output current proportional to the output torque?
- The output voltage of the inverter is proportional to the frequency, which is to keep the motor flux constant, T = KIφ so the motor output torque is proportional to the inverter current.
- Q: Is the laptop power adapter long-haul?
- This is not good, If you need to shut down, then it is recommended that the power adapter plug from the board to pull down. Because if only pull the adapter and the computer plug so that the adapter will still have the internal current through, hear the small sound is actually the sound of the current. So it is recommended that the power adapter from the outlet on the unplugged, and the computer connected to the one do not have to pull, so that will not cause the power adapter power and convenient computer to open.
- Q: Why the number of motor poles increased, the inverter capacity will increase
- The power of the three-phase motor is equal to the root number of 3 times the line current and the line voltage of the product again good with the power factor. Can also be 3 times the phase current and phase voltage of the good product and then good to power factor. The frequency converter should match the rated current of the motor, not the power of the motor.
- Q: Do not the laptop directly connected to the power adapter?
- 3, the notebook internal circuit using low-voltage direct current work, if the direct use of 220V AC and its connection will burn the circuit in the low-voltage devices, which is absolutely prohibited, but also basic common sense. At the same time, its external power jack is also dedicated, and the AC outlet is different;
- Q: I power adapter output current 3.25A for a 4.5A, can you use it
- No problem that nominal value is that the adapter can provide the maximum operating current to your computer current is not so big
- Q: What is the maximum speed adjustable for a 4-stage motor with a rated frequency of 50Hz / 60Hz?
- Asynchronous motor speed depends on the maximum speed of the bearing, theoretically look at what the choice of bearing, above the rated speed into the constant power area, with the increase in speed torque becomes smaller, but the motor constant power area is limited, usually ordinary asynchronous motor rated Voltage is 380v motor constant power area is the motor rated speed of 2.5 to 3 times, if you want to get a higher constant power area can be reduced by the way to reduce the rated voltage constant power area, if you do not consider the reasons for mechanical bearings, asynchronous motor Speed depends on what speed the motor torque can overcome the resistance to maintain the speed.
- Q: How to choose a Siemens inverter for a 5.5KW three-phase motor (2 pole)?
- Siemens frequency conversion dedicated input / output filter, reactor, you contact us but smell it, the quality is guaranteed. We look forward to cooperation.
1. Manufacturer Overview
Location | Zibo, China |
Year Established | 2004 |
Annual Output Value | Below US$1 Million |
Main Markets | Middle-East America; Mid East; Northern Europ; Africa; Southeast Asia |
Company Certifications | CE;ISO |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | Qingdao |
Export Percentage | 1% - 10% |
No.of Employees in Trade Department | 500-999 People |
Language Spoken: | English; Chinese |
b) Factory Information | |
Factory Size: | Above 50,000 square meters |
No. of Production Lines | Above 8 |
Contract Manufacturing | |
Product Price Range | High; Average |
Send your message to us
CE Approved 90KW Inverter Frequency
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1 pc pc
- Supply Capability:
- 5000pcs per month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords