Specifications of Cable Conductor HS-201
ACSR Conductor Cable
1.Conductor:Hard drawn aluminium wire
2.Steel core:Galvanized steel wire,solid or concentric stranded
ACSR Conductor, Aluminium Conductor Steel Reinforced of Cable Conductor HS-201
Aluminum Conductors Steel Reinforced ACSR ASTM B 232 of Cable Conductor HS-201
Area |
Stranding and wire diameter |
Approx. overall diameter |
Weight |
Nominal breaking load |
Nominal DC resistance at 20 deg. | ||||||
Nominal |
Alum. |
Steel |
Total |
Alum. |
Steel |
Alum. |
Steel |
Total | |||
AWGorMCM |
mm2 |
mm2 |
mm2 |
mm |
mm |
mm |
Kg/km |
Kg/km |
Kg/km |
kN |
Ohm/km |
1272 |
644.51 |
81.68 |
726.19 |
54/3.90 |
19/2.34 |
35.10 |
1795 |
638 |
2433 |
194.00 |
0.04516 |
1272 |
644.51 |
17.87 |
662.38 |
36/4.78 |
1/4.78 |
33.42 |
1777 |
140 |
1917 |
115.85 |
0.04472 |
1351.5 |
684.84 |
47.10 |
731.94 |
45/4.40 |
7/2.92 |
35.16 |
1898 |
368 |
2266 |
160.70 |
0.04230 |
1351.5 |
684.84 |
86.71 |
771.55 |
54/4.02 |
19/2.41 |
36.17 |
1906 |
679 |
2585 |
206.05 |
0.04250 |
1431 |
725.10 |
50.32 |
775.42 |
45/4.53 |
7/3.02 |
36.24 |
2009 |
393 |
2402 |
170.71 |
0.03994 |
1431 |
725.10 |
91.87 |
816.97 |
54/4.14 |
19/2.48 |
37.24 |
2019 |
719 |
2738 |
218.24 |
0.04013 |
1510.5 |
765.35 |
52.90 |
818.25 |
45/4.65 |
7/3.10 |
37.20 |
2120 |
414 |
2534 |
177.89 |
0.03784 |
1510.5 |
765.35 |
96.84 |
862.19 |
54/4.25 |
19/2.55 |
38.25 |
2131 |
759 |
2890 |
230.20 |
0.03802 |
1590 |
805.68 |
55.48 |
861.16 |
45/4.77 |
7/3.18 |
38.16 |
2232 |
435 |
2667 |
187.02 |
0.03595 |
1590 |
805.68 |
102.13 |
907.81 |
54/4.36 |
19/2.62 |
39.26 |
2243 |
799 |
3042 |
242.55 |
0.03613 |
80 |
40.52 |
14.13 |
54.65 |
8/2.54 |
1/4.24 |
9.32 |
112 |
110 |
222 |
23.60 |
0.7115 |
101.8 |
51.61 |
30.06 |
81.67 |
12/2.34 |
7/2.34 |
11.71 |
143 |
235 |
378 |
41.75 |
0.5613 |
110.8 |
56.13 |
32.77 |
88.90 |
12/2.44 |
7/2.44 |
12.22 |
156 |
256 |
412 |
51.25 |
0.5161 |
134.6 |
68.19 |
39.81 |
108.00 |
12/2.69 |
7/2.69 |
13.46 |
189 |
311 |
500 |
61.70 |
0.4248 |
159 |
80.58 |
46.97 |
127.55 |
12/2.92 |
7/2.92 |
14.63 |
223 |
367 |
590 |
72.55 |
0.3595 |
176.9 |
89.48 |
52.19 |
141.67 |
12/3.08 |
7/3.08 |
15.42 |
248 |
409 |
657 |
78.50 |
0.3237 |
190.8 |
96.71 |
56.39 |
153.10 |
12/3.20 |
7/3.20 |
16.03 |
268 |
441 |
709 |
84.80 |
0.2995 |
203.2 |
102.97 |
91.87 |
194.84 |
16/2.86 |
19/2.48 |
18.14 |
285 |
722 |
1007 |
128.80 |
0.2813 |
211.8 |
107.10 |
62.45 |
169.55 |
12/3.37 |
7/3.37 |
16.84 |
297 |
488 |
785 |
93.90 |

- Q: Four lines only reached a phase line, at the other end all charged, I use the digital pen! In addition, I often check the cable when the cable current through the dot digital pen voltage symbols sometimes have time to disappear, in other bare wires when the test keys are normal! What is this going on! Ask the heroes to give the younger brother a complete point of the answer! More
- Bookstore tool book should have "communication project budget", I do is what you say, the budget is divided into estimates and budget, is two steps. So that is not very clear. But what is needed is the preliminary design of the project. The budget is needed for design and drawings. Internal management of this piece, the main thing is that you need to do what the project department, and are generally very complicated
- Q: Engineering materials inspection, all types of cable wires should be issued a test report?
- You look at your TV behind the interface dvd are generally with the color of the port (green red and blue) interface you dvd the best copy of the flowers deduction ditch dumplings evil spear that interface on the LCD TV certainly with that color interface so that your set-top box Then the av interface (yellow) video port on the line there is a way set-top box with a terminal is the same as the mouse with the same interface with the mouse with the video port plus two voice interface on the line that is better than the av interface can also solve the problem LCD TV certainly Will take that interface you look at the set-top box and dvd have any different interface on the use of the impossible can not only two mouth it (yellow interface) and 40-inch LCD TV is generally high-end are generally two An av channel input you are inserted two lines are also ah
- Q: Remove the computer and wash it off. What the motherboard did not move it, that is, the dust of those dust sasses, as well as the other wire of the skin what Sassafras wash, but the computer re-connected to the Internet when the old mistakes . and the lower right corner of the red Fork appears, disappeared after the emergence. The The Said the network cable is not plugged in, but the MODERN that POWER, LINK, LINE, 3 lights are normal display. The The This is how the matter, and just also appeared keyboard and mouse just start the machine can also be used normally, but in a moment to fall, and then plug their plug re-plug the mouse lights can be displayed, but the lights on the keyboard simply do not Bright, restart the computer but good, what is going on? bother. The The I hope the master quickly to help me, and this machine is relatively old ah No problem added: on a machine, just tried to re-create a connection in the network neighborhood, useless more
- Galvanized itself on the anti-corrosion, no need to do anti-corrosion treatment.
- Q: Do not know why not mislead. The The The The The Fire resistance is IECGBBS6387. GB is the general principle of flame retardant and fire resistant wire and cable, quoted the above criteria...........................
- About 140 PVC threading tube, which depends on how many lines you row. PPR cold / hot water pipe 42 meters, PPR cold / hot water pipe with 4 m / root and 6 m / root of the points, short will make the joints more recommended to use long, generally longer expensive. Decoration in meters to count, to facilitate the settlement of labor, 42 meters is the amount of my home My house 115 square meters, indoor area of 98 square meters. I hope useful to you. According to the 2011 price, the general brand of wires and pipes, their own materials to buy, without artificial about 4000-5000 yuan. I decorated last year, the package to the decorating company hydropower workers with me to calculate the 9800 yuan it, of course, each region has a price difference.
- Q: How to determine how much wire and cable should be used, the current load and how the corresponding wire, such as 4BV, under what circumstances, YJV240 what circumstances, the load is much more
- According to the control cable and the power of the different layers of laying, if the power cable to be multi-layer need to have 300mm spacing (or load capacity is large enough), if it is control cable, casually laying, if the laying of power cable laying below Layer, above the laying of control cable, but not too much affect the power cable cooling. If the high-voltage cable and low-voltage cable in principle do not allow common laying.
- Q: Wire and cable: RVFV. : RVFSV. : UTP-CAT5E. : SYV-F-75-5 : RVFSP. : RVSP. : RVFVSP. What is the type of wire? Solve! More
- If you need an unqualified wire, you can contact this part
- Q: Decoration when the purchase of water pipes, wires and other items included in the account
- Outdoor fire line must use fire-resistant KVV cable, wear pipe protection.
- Q: Why this cable has not yet been certified
- Electromechanical products are usually used to be assembled into parts, multiple parts and then assembled into a single product, the number of products or the number of pieces measured
- Q: Why does the bird stand on the wire without anything, but if people touch it,
- Is not the home of the bus box? Generally put a cat, a router, a power outlet, two transformers, the other is the network cable and telephone, the key space to be enough
- Q: Wire and cable fire resistance to meet what standards, which can provide about, thank you!
- Do not know why not mislead. The The The The The Fire resistance is IECGBBS6387. GB is the general principle of flame retardant and fire resistant wire and cable, quoted the above criteria...............