EPDM Waterproofing Membrane for Roof Only

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
50000 m²
Supply Capability:
5000000 m²/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

EPDM Waterproofing Membrane for Roof Only

 

 Description Of EPDM Waterproofing Membrane for Roof Only:

This waterproof coiled material is of high elasticity with best performance among high polymer waterproof coiled material in the world.It is also the most typical one in the world.Waterproof coiled material made of ternary ethylenepropylene rubber of KINTOPbrand is produced with the use of the most advanced continuous extrusion and vulcanization technology and related equipments which are specially designed for production of such product.It is good in compactness,without bubble and performance difference in length and breadth.



 Main Features of EPDM Waterproofing Membrane for Roof Only: 

1>Excellent anti-aging performance, service life up to 50 years

2>Working well with in -40°C to 100°C,it can be constructed with a single layer in ambient temperature.

3>Waterproofing on various kinds of underground project,industrial of civil buildings and structures.

4>high extension rate, high tensile strength, small size changes at heat treatment

5>Good plant roots penetrability resistance and can be made waterproofing layer of planting roof

6>Special modified molecular structure ,effectively resolving the current domestic and foreign glue 

joint problem .

7>Good low temperature flexibility, and good performance of adapting to ambient temperature 

changes.

8>Convenient application ,solid joint, no environment pollution

9>chemical corrosion Resistance, can be used for special occasions

                                    



Specifications of EPDM Waterproofing Membrane for Roof Only:

 

Type

EPDM Rubber Waterproof   Membrane

Type

Vulcanized and Weldable

Thickness

1.2mm

1.5mm

2.0mm

Weight(kg/m2)

1.54-1.58

1.79-1.83

2.25-2.29

Size

1.2m (width) * 20m (length)/roll.    Weldable type could be 4m wide.

Packing

24/roll, with plastic bag. (Weldable: 80/roll)

Usage

Roof, basement, pond, Lake, steel structure roofing,   underground, tunnel, etc

NO.

Item

Unit

Technical requirement

1

Tolerance on size

Thickness

%

±10

Width

%

±1

length

%

Does not allow negative

2

Fracture tensile strength (normal temperature )

Mpa

≥7.5

Fracture tensile strength(60 )

Mpa

≥2.3

3

Breaking elongation,(normal temperature )

%

≥450

Breaking elongation,(-20 )

%

≥200

4

Tearing resistance

KN/m

≥25

5

Impermeability

*

0.3Mpa impermeable

6

Bending at low temperature

°C

≤-40

7

Elongation and contraction volume at heating

Elongation

mm

≤2

contraction

mm

≤4

8

Hot air aging 80°CX168h

Fracture strength retention

%

≥80

Rate of elongation at break

%

≥70

9

Alkaline (saturated Ca(OH)2  solution normal

Temperature x2  168h )

Fracture strength retention

%

≥80

Rate of elongation at break

%

≥80

10

Ozone aging (40 degree by 168 hours )

Elongation 40% , 500x10-2

*

No Crack

11

Phytotron aging

Fracture strength retention

%

≥80

Rate of elongation at break

%

≥70


Applications of EPDM Waterproofing Membrane for Roof Only: 

Widely used in roofs, basement, toilet ,swimming pool, and all kinds of industry and civil building waterproofing, reservoir, vivicism, bridge, underground, tunnel and dam waterproofing ,especially to the keystone waterproofing projects which is durability, high corrosion resistance and easy deformation.



Construction Site of EPDM Waterproofing Membrane for Roof Only:

EPDM Waterproofing Membrane for Roof Only

EPDM Waterproofing Membrane for Roof Only

EPDM Coiled Rubber Waterproof Membrane for Roof Waterproof System

 

IMages of EPDM Waterproofing Membrane for Roof Only:

EPDM Coiled Rubber Waterproof Membrane for Roof Waterproof System

EPDM Coiled Rubber Waterproof Membrane for Roof Waterproof System

EPDM Coiled Rubber Waterproof Membrane for Roof Waterproof System

EPDM Coiled Rubber Waterproof Membrane for Roof Waterproof System

 

FAQ of EPDM Waterproofing Membrane for Roof Only:


1. What are we supplying?

We are specialized in producing Colorful Asphalt Roof Shingle, SBS/APP modified bitumen waterproof membrane, Self adhesive bitumen waterproof membrane, PVC waterproofing membrane, EPDM rubber roofing membrane, Single Component Polyurethane Waterproof Coating, and Spray Polyurea Waterproof Coating

 .

2. How Many years experience do we have?
We have been exported to more than 20 countries in the past 15 years.


3. How long do we usually reply your request?

We always reply our customer within 24 hours.

 







Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Basement SBS Waterproof Coil Division I and II type What is the difference? How is the site identified?
SBS type I and type II differences are mainly low temperature flexibility and tensile extension
Q:The shortcomings of polypropylene waterproofing, and the shortcomings of modified asphalt waterproofing membrane
The advantages of the membrane waterproof, such as: the construction is convenient, the construction period is short, not need to be cured after forming, is not affected by the temperature, the environmental pollution is small, the layer thickness is easy to hold and hold the fortification meter, the material is calculated accurately, the site management is convenient, Cut corners, even thick layer, empty shop can effectively overcome the grass-roots stress (effective in the grass-roots cracks to maintain the overall waterproof layer).
Q:What should the attention of the membrane waterproof construction?
(1) grass-roots coating on the base layer of treatment agent, requiring thin and uniform, generally dry, when the sticky hand can be paving the membrane;
Q:What is the preferred level of waterproofing?
2, roof 2 waterproof: Applications: important buildings and high-rise buildings; Waterproof layer of reasonable use of life: 15 years; Waterproof layer selection of materials: should choose high polymer modified asphalt waterproofing membrane, synthetic polymer waterproofing membrane, metal sheet, synthetic polymer waterproof coating, high polymer modified asphalt waterproof coating, fine stone concrete, flat tile, linoleum Tile and other materials; Fortification requirements: two waterproof fortification.
Q:How to distinguish whether the waterproofing membrane is polyester tires?
Polyester tires (polyester fabric, polyester felt, polyester linoleum fabric) with high strength, high extension and puncture resistance, light weight, high tensile strength, good permeability, high temperature, anti-freeze, anti-aging, corrosion. Technical requirements, including the appearance of quality, intrinsic quality assessment projects and internal quality reference project, the indicators are in line with the provisions of the waterproof standards. Routine project tests should be in accordance with national standards test methods, thermal stability, bending, impregnation, water resistance test methods have done a detailed test.
Q:Polyurethane and SBS membrane waterproof
SBS membrane, also known as modified asphalt waterproofing membrane, asphalt waterproof material;  Polyurethane is rubber and plastic mine waterproof material;
Q:How to choose waterproof membrane
Third, from the physical quality of strict quality off From the appearance of visual inspection can only distinguish the composite tire coil, but failed to solve the selected products meet the quality requirements, which requires users to have the ability to test the technical institutions, according to the corresponding product standards for soluble content The physical properties of the factory test, with the soluble content of the project to control the product contains the amount of asphalt and modifier, but also to reveal the product used in the real face of the fetus can determine whether it is consistent with the product mark.
Q:SBs waterproof cold sticky how to do?
Waterproof membrane cold sticking method construction points: 1, grass-roots inspection, cleaning. Cold sticky paste, the grassroots must be clean, dry, moisture content in line with design requirements, or easy to cause paste is not strong and drums. Therefore, before the construction, the grass-roots surface of the protrusions should be eradicated, and dust debris and other completely clean.
Q:Asphalt waterproofing membrane and polymer waterproofing membrane
Polymer modified asphalt waterproofing membrane according to the polymer modifier material is divided into: elastomer modified asphalt waterproofing membrane and plastic modified asphalt waterproofing membrane.
Q:Is the asphalt waterproofing membrane facing the side?
Because there are many types of self-adhesive waterproofing membrane, their use and construction methods are different, there are two main methods. 1, the normal self-adhesive paving method: the film directly paving or polymer cement cement wetting method, paste in the grass-roots level. The bottom of the floor floor of the building, in the concrete cushion with cement mortar leveling, and then the coiled surface of the membrane down, paste in the leveling layer, the roll surface pouring 50 thick stone concrete protective layer, Floor concrete. Wall construction, the film directly attached to the basement wall panels, and then do the protective layer on the outside. Commonly used modified asphalt self-adhesive waterproofing membrane, modified asphalt wet sheet is usually used in this method.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range