Ceramic fiber blocks for thermal insulation
1.Excellent chemical stability
2.Excellent flexibility
3.Low heat capacity

Item name:  Standard Ceramic Fiber Folding Block

Ceramic fiber blocks for thermal insulation

All kinds of ceramic fiber folded block, using the corresponding materials are ceramic fiber blanket acupuncture, according to fiber components of the structure, size and mechanical processing on the dedicated form.  

In the course of processed, are to maintain a certain proportion of compression to ensure the ceramic fiber lining folded block wall construction has been completed, because each piece of folded pieces of ceramic fiber in different directions on the expansion,

so that pieces of ceramic fiber folded between the extrusion into a seamless whole.

Product Characteristics

1.Excellent chemical stability;

2.Excellent thermal stability;

3.Excellent flexibility, because of fiber in a pre-compression state, and its expansion can be compensated fiber contraction, improve the insulation properties of fiber lining;

4.Low heat conductivity;

5.Low heat capacity.

Technical Specifications

Item Product

COM

ST

HP

HA

HAZ

HZ

Specification Tem(°C)

1050

1260

1260

1360

1360

1430

Working Tem(°C)

950

1050

1100

1200

1280

1350

Color

white

white

white

white

white

white

Density(kg/m3)

200/220

200/220

200/220

200/220

200/220

200/220

Rate of liner(%)
(24h,Density 200kg/m3)

-3
(950°C)

-3
(1050°C)

-3
(1100°C)

-3
(1200°C)

-3
(1280°C)

-3
(1350°C)

Rate of thermal(%)conductivity
(w/m.k )(Density 200kg/m3)

0.09(400)
0.176(800)

0.09(400)
0.176(800)

0.09(400)
0.22(1000)

0.132(600)
0.22(1000)

0.132(600)
0.22(1000)

0.76(600)
0.22(1000)

AL2O3(%)

42-44

45-46

47-49

52-55

45-46

39-40

AL2O3+SIO2(%)

96

97

99

99

---------

-------

AL2O3+SIO2+ZrO2 %

----------

---------

-----------

----------

99

99

ZrO2(%)

----------

---------

-----------

----------

99

99

Fe2O3(%)

<1.2

<1.0

0.2

0.2

0.2

0.2

Na2O+K2O(%)

≤0.5

≤0.5

0.2

0.2

0.2

0.2

Size (MM)

300×300×300/250

Specifications

Ceramic fiber blocks for thermal insulation
1.Excellent chemical stability
2.Excellent flexibility
3.Low heat capacity

Item name:  Standard Ceramic Fiber Folding Block

Ceramic fiber blocks for thermal insulation

All kinds of ceramic fiber folded block, using the corresponding materials are ceramic fiber blanket acupuncture, according to fiber components of the structure, size and mechanical processing on the dedicated form.  

In the course of processed, are to maintain a certain proportion of compression to ensure the ceramic fiber lining folded block wall construction has been completed, because each piece of folded pieces of ceramic fiber in different directions on the expansion,

so that pieces of ceramic fiber folded between the extrusion into a seamless whole.

Product Characteristics

1.Excellent chemical stability;

2.Excellent thermal stability;

3.Excellent flexibility, because of fiber in a pre-compression state, and its expansion can be compensated fiber contraction, improve the insulation properties of fiber lining;

4.Low heat conductivity;

5.Low heat capacity.

Technical Specifications

Item Product

COM

ST

HP

HA

HAZ

HZ

Specification Tem(°C)

1050

1260

1260

1360

1360

1430

Working Tem(°C)

950

1050

1100

1200

1280

1350

Color

white

white

white

white

white

white

Density(kg/m3)

200/220

200/220

200/220

200/220

200/220

200/220

Rate of liner(%)
(24h,Density 200kg/m3)

-3
(950°C)

-3
(1050°C)

-3
(1100°C)

-3
(1200°C)

-3
(1280°C)

-3
(1350°C)

Rate of thermal(%)conductivity
(w/m.k )(Density 200kg/m3)

0.09(400)
0.176(800)

0.09(400)
0.176(800)

0.09(400)
0.22(1000)

0.132(600)
0.22(1000)

0.132(600)
0.22(1000)

0.76(600)
0.22(1000)

AL2O3(%)

42-44

45-46

47-49

52-55

45-46

39-40

AL2O3+SIO2(%)

96

97

99

99

---------

-------

AL2O3+SIO2+ZrO2 %

----------

---------

-----------

----------

99

99

ZrO2(%)

----------

---------

-----------

----------

99

99

Fe2O3(%)

<1.2

<1.0

0.2

0.2

0.2

0.2

Na2O+K2O(%)

≤0.5

≤0.5

0.2

0.2

0.2

0.2

Size (MM)

300×300×300/250



Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What is the appropiate thickness if fire resistant time for ultra thin steel structure coating is 2.5 hours?
According to the "code for fire protection design of tall buildings", the fire resistance time of the component is at the first level: 3 hours, beam: 2 hours, floor: 1.5 hours;if fire resistance level is level the requirement for time of fire resistance component is the column: 2.5 hours, beam: 1.5 hours, floor: 1 hours. For fire resistant coating, fire resistance time for ultra-thin fire retardant coating is shorter than 1.5 hours. If the time exceeds 1.5 hours, thick fire resistive coating should be used. Steel structure can adopt surrounding concrete or brick, fireproof coating, fireproof board coating and composite structure for its fire resisitance. Fire resisitance board can be divided into thick fire protection plate and thin plate, the thickness of the plate thickness of the fire is between 20 ~ 50mm, mainly includes calcium silicate fireproof board and expansion boring stone fire board, the main varieties are KB board, CF; thin fireproof plate is between 6 ~ 15mm thick, the main varieties include enforced short fiber cement plate, ordinary enforced fiber silicate calcium board and glass cloth reinforced inorganic board. As is known to all, steel structure usually will lose bearing capacity usually in 450 to 650 degree, leading to deformation, steel column and beam bending, and be no longer usable at last. Generally fire resistant limit of unprotected steel stucture is about 15 minutes. 1.5 hours;if fire resistance level is level the requirement for time of fire resistance component is the column: 2.5 hours, beam: 1.5 hours, floor: 1 hours. Steel structure an use surrounding concrete (or masonry), fire retardant coating, fire retardant plate and compround structure to achieve the required refractory limit. Hope my answer will help you.
Q:Who knows about ranking rules of fireproofing thermal insulation materials for exterior wall?
(1) the height of buildings is greater than or equal to 24 m, the combustion performance of thermal insulation material should be A-level. (2) the height of buildings is less than 24 m, the combustion performance of thermal insulation materials should be A- or B1-level. When using B1-level thermal insulation materials, fire barrier zone should be set in each floor. (3) incombustible materials should be used as the protective layer of thermal insulation materials. Thermal insulation materials should be completely covered by protective coatings. The thickness of protective layer should be no less than 3 mm. (4) The base walls should be set in buildings with nontransparent curtain wall structures of metal, stone,etc. The fire endurance of which should comply with relevant provisions of current fire safety rules on fire endurance of external wall. The fire endurance and fire protection construction of pier between two windows, window sill walls, skirt walls of glass curtain walls should comply with relevant provisions of current fire safety rules on building curtain walls. (5) the internal cavity of base walls, as well as the space between the skirt wall and base walls, pier between two windows, window sill walls should be sealed with fire-proof sealing materials at each floor.
Q:I want to know what is the slim in the refractory bricks
Where are you from, I can introduce to you
Q:What are the differences between intensive refractory busway and other busways?
Compact busway is named after its structure, especially referring to busway which is closely laminated between phases and between phase and shell and use thin insulating material to achieve the insulation result. Fire-resistant busway is named after its uses, just as its name implies, for higher fire safety requirements need busway of higher fire resistance level. The structural style of fire-resistant busway can be intensive and of air type, depending on what material it use to resist fire, so there is no direct link between them, but there is a included relationship.
Q:what is the material of fixed first rate fire resistant window?
Window frames and fireproofing glass, fire sealing strip, fireproofing glass mound layer, which is infexible fan, and the flexible fans have to plus folding and closing window cleaner. (3) window frames must be integral with the building, using wood or iron to connect the wall. After the installation of the steel frame, the cement mortar must be watered between the window frame and the wall, and it should conserve more than 24 hours before normal use.
Q:What are the types of advanced refractory?
According to the chemical composition of minerals,refractory can be divided into eight categories: 1, siliceous material. 2, aluminosilicate materials. 3, magnesia materials. 4, dolomite materials. 5, chromium materials. 6, the carbonaceous material. 7, zirconium materials. 8, special refractories. 1. refractories according to chemical properties can be divided into three categories: 1, acidic refractory materials. 2, neutral refractories. 3, basic refractories. 1. refractories according to chemical properties can be divided into three categories: 1, ordinary refractories, refractoriness is 1580-1770 degrees. 2, advanced refractories refractoriness is 1770-2000 degrees. 3, super refractories refractoriness higher than 2000 degrees. 3. refractory according to the forming process can be classified into seven categories: 1, natural rock molding process. 2, compression moulding refractories. 3, moulding refractories by casting. 4, plastic molding refractories. 5, ramming molding refractories. 6, injection molding refractories. 7, extrusion molding refractories.
Q:The classification of fire-resistant material
There are various refractory materials classified according to the chemical properties of material: Min< manufacturing technique: neutral refractory materials, pipes, etc. Standard model: baidu.hiphotos;8 simatic carbon composite refractory material zirconia based refractory material special fire-proof material 6; or a acute angle of 50~70° and material forms. 3.
Q:Which brand of thermal insulating refractory is good?
The most famous is the dragon, Morgan, Luyang, which are good at making ordinary thermal insulation materials and whose products are cheap but quality. Guangdong ALISON nanometer aerogel is more expensive. The heat conductivity coefficient is 0.018. It can work under 1000℃
Q:How to divided the grade of external wall thermal insulation materials?
Synthesized the three versions of GB8624 (1997,2006,2011), external wall thermal insulation fire rating can be basically divided into: A1, A2, B1, B2, B3 and other levels. There are many technical indicators to make specific division, but I partly cannot report for a while, because it is very professional and technical. I hope I can help you!
Q:how long is the fire endurance of plasterboard?
fireproof endurance can reach a maximum of 4hours, suitable for a variety of public buildings firewall, and partitions for public exit passageway, reaching standard level of fireproof. the lightweight partition made of gypsum board and steel stud is mainly for dividing architecture space. Rock wool can be filled in the mddle according to its design requirements, using different series of gypsum board, steel stud. the walls may have fire resistance and sound insulation property of various degrees.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range