Online UPS 20KVA
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Online UPS 10-20KVA
The XPC series 10-20K series is applicable to small and medium-sized data centers, network management center, computer rooms for enterprises, or able to provide solutions to conditions like voltage instantaneous drop-off or damping concussion, high-voltage pulse, voltage pulsation, surge voltage, harmonic distortion, and frequency fluctuation. XPC series 10-20K series UPS provide customers safe and sound power supply.
Excllent performance in industrial environment protection
Just with the standard product, IP21 protection level (protecting the machine from the intrusion of solid material
with the diameter larger than 12mm or the water drops) is achieved. If a higher protection level is required, the
optional dust-proof accessories can help to increase the protection level in industrial environment and safeguard
the ups security when operation in bad environment.
Ientelligent management of battery charging and discharging
The advanced battery intelligent charging technology enables the UPS's charger to rectify the charging parameter,
and provide the optimum charging modes in the different environment, types and amounts of cells, and the using
condition of the battery. The scientific charging mode extends the battery's lifetime. The optional addition to
charging units shortens battery charging time.
Front board operation and maintenance
The smart module design and front board design make the users operation more conveniently and easily.
Remote monitoring
Communication interfaces like RS232/RS485, Intelligent Slot of JingFuYuan Company are available for the realization
of remote management and monitoring.
High-efficient DSP chip
The digital Ti DSP controlling chip provides precise data processing capability with excellent performance in output
and reliability.
Outstanding electric property
The efficiency of the machines is as high as 93% and reaches over 98% in the ECO mode, which can help reduce the
power loss of UPS. Because of the technology of IGBT FM intelligent rectifier and inverter is used , the input power
factor is as high as 0.99,and the input current harmonic wave is as low as 3%,which makes the output voltage electric
property more extraordinary.
Powerful overload capacity: the ups can work normally up to 10 mins under the condition of 110-125% load and 1
minute in load of 125-150% . It also has the output short circuit protection capability.
MODEL | XPC 3110L | XPC 3115L | XPC 3120L |
Rated Power | 10KVA/8KW | 15KVA/12KW | 20KVA/16KW |
INPUT | |||
Phase | 3W+N+G | ||
Input Voltage | (207-475)VAC | ||
Input Frequency | (46-54)Hz | ||
Input PF | >0.95 | ||
Bypass voltage | (302-437)VAC | ||
OUTPUT | |||
Output Voltage | 220VAC±1% | ||
Output Power Factor | 0.8 | ||
Output Frequency | Normal mode:same with utility power Battery mode:49.9~50.1Hz | ||
THD | THD<3% (linear load);THD<5% (non-linear load) | ||
Transfer Time | Normal to battery mode: 0ms Bypass mode to normal : 0ms | ||
Overload Capability | load≤105±5%:normally run;normal mode,turn to normal mode after overload disappearing 105±5%<load≤135±5%:60s 135%≤load≤150±5%:30s >150%:0.1s | ||
BATTERY | |||
Voltage | 192Vdc | ||
Charging voltage | 220Vdc | ||
Overvoltage | 230Vdc | ||
Charging Current | 2A/4A(L type) | ||
SYSTEM | |||
Efficiency | >92% | ||
Communication | LCD display+RS-232 + Intelligent slot | ||
Restart Function | After turning off due to cut off voltage of battery, UPS will restart when voltage is in (302~437Vac) and frequency is in (47~53Hz). | ||
Noise (1m front) | <45dBA | <50dBA | |
Operation Temperature | 0°C to 40°C | ||
Humidity | 0~95% non-condensing | ||
Storage Temperature | -40°C to 50°C | ||
Altitude | 1000m | ||
Dimension(WXDXH) | 248×500×616 | ||
Weight(kg) | 27 | 35 | 35 |
Specification is subject to change without prior notice. |
- Q:Just like ordinary power outlets? System to set up what power? Stress? Power and chassis power supply the same? Will not affect the chassis voltage?? good UPS price? Home ~ ~ to buy this power in general where to buy?Back to the 1 floor, I use a computer, choose what type of comparison, the quality of the relatively good price?Computer city will be sold... After a few days to see what brand is better?
- UPS is a power fail delay device designed to prevent loss of system information with a maximum duration of 15 minutes
- Q:Excuse me: how long is the service life of the UPS power supply?
- A few years is ok. Look at the brand, look at the model, see the use of the environment.
- Q:UPS uninterrupted power supply, how long can you extend the power supply?
- The backup UPS general built-in 4AH or 7AH battery, the standby time is fixed; the standard model of online and interactive online UPS with built-in 7AH battery, there are long-term models with a large capacity battery, the user can set equipped with large capacity battery standby time according to the need to achieve.UPS power backup delay time calculation method: (battery capacity, X, battery operating voltage) / equipment power = extended time (hour).
- Q:60 cameras, 4 video distributors, 1 video matrix controllers, 4 hard disk video recorders, one server, 5 22 monitors, 4 cameras
- I'll calculate it as a rule:The power CCD camera board in 1 to about 2W, such as infrared camera, infrared lamp power of 2 to 60 cameras ranging from 15W, 10*60=600W estimation;4 Video Splitter 4*5=20W,1 video matrix controllers 300W,4 hard disk recorders are usually around 15W, that is, 15*4=60W,A server dl388 comes with 460W,
- Q:What are the features of the UPS uninterruptible power supply?
- The main features of UPS power supply include over current alarm, over voltage protection, short circuit protection, overload protection and short circuit alarm. Some of the UPS is now intelligent, in power (level discipline), power planning, design and construction (two disciplines), hospitals, banks, securities and other departments. When the power input is normal, UPS electric voltage supplied to the load, the UPS is an AC power regulator, it is also the built-in battery; when the power interruption (outage), UPS will immediately machine battery power through the inverter conversion method continue to supply 220V AC power to the load, the load to maintain normal working load and protection of software and hardware are not damaged, that is the work of the normal operation of equipment; is processing the data is not lost.
- Q:There are several ups
- Reserve UPS power supply mode is that the city power input UPS power, divided into two running, all the way for equipment direct power supply, the other way through the UPS power supply will be converted to DC power supply for battery charging
- Q:What is UPS?
- UPS has evolved from the 60s rotary generator to today's intelligent, fully static electronic circuit and continues to develop. At present, UPS generally refers to the static UPS, classified according to its way of work, can be divided into backup, online interactive and online three categories.1. backup type UPS: when the city power is normal, the power supply is directly supplied by the city to the load. When the power supply exceeds the scope of work or the power failure, the power supply is transformed into a battery by inverting the switch. The utility model is characterized in that the structure is simple, the volume is small, and the cost is low, but the input voltage range is narrow, the output voltage is stable, the precision is poor, and the switching time is also available, and the output waveform is generally Fang Bo2. line interactive UPS: in the normal electricity directly by electric power to the load when the power is low or high, through the UPS internal voltage regulator circuit voltage output, when power failure or abnormal, through the switch to battery powered inverter. Its characteristics are: wide input voltage range, low noise, small size and so on, but there is also switching time3. online UPS when power supply is normal, the rectifier provides DC voltage to the inverter by electricity from the inverter to provide AC power load, power anomaly in the city when the inverter powered by battery, the inverter always in working condition, ensure uninterrupted output. The utility model is characterized in that the utility model has the advantages of extremely wide input voltage range, no switching time, stable output voltage and high precision, and is especially suitable for occasions with high power supply requirements, but the cost is higher. At present, UPS with power greater than 3KVA is almost all online UPS
- Q:What is the working principle of the UPS power supply?
- On line staggered online interactive working principleLine interleaving also known as online interactive or online interactive (Line-Interactive UPS), the basic mode of operation and off-line, the difference is that online is not interleaved on-line in the whole power supply, but all the time in the power supply condition monitoring of city electricity, has boost and decompression compensation circuit in the power supply situation, real-time correction electricity is not ideal, and reduce unnecessary "Battery Mode" switch to extend battery life.
- Q:What is the name of the device that provides the server with power?
- UPS is the abbreviation of uninterruptible power system, which is an important external equipment to provide continuous, stable and uninterrupted power supply.
- Q:Why can ordinary UPS power only take a few minutes?
- The voltage is on the low side, and the UPS can only be powered by batteries, accompanied by alarm. The new battery has not been out for only a few minutes. Monitor host will crash. When you measure the voltage is normal, should be the same line, there is a larger power load, there is a sudden start phenomenon. And the battery may be out of commission.
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Online UPS 20KVA
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products
Hot Searches
Related keywords