• Online UPS 15KVA System 1
Online UPS 15KVA

Online UPS 15KVA

Ref Price:
get latest price
Loading Port:
Shekou
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Online UPS 10-20KVA

The XPC series 10-20K series is applicable to small and medium-sized data centers, network management center, computer rooms for enterprises, or able to provide solutions to conditions like voltage instantaneous drop-off or damping concussion, high-voltage pulse, voltage pulsation, surge voltage, harmonic distortion, and frequency fluctuation. XPC series 10-20K series UPS provide customers safe and sound power supply.

Excllent performance in industrial environment protection
Just with the standard product, IP21 protection level (protecting the machine from the intrusion of solid material
with the diameter larger than 12mm or the water drops) is achieved. If a higher protection level is required, the
optional dust-proof accessories can help to increase the protection level in industrial environment and safeguard
the ups security when operation in bad environment.


Ientelligent management of battery charging and discharging
The advanced battery intelligent charging technology enables the UPS's charger to rectify the charging parameter,
and provide the optimum charging modes in the different environment, types and amounts of cells, and the using
condition of the battery. The scientific charging mode extends the battery's lifetime. The optional addition to
charging units shortens battery charging time.


Front board operation and maintenance
The smart module design and front board design make the users operation more conveniently and easily.


Remote monitoring
Communication interfaces like RS232/RS485, Intelligent Slot of JingFuYuan Company are available for the realization
of remote management and monitoring.


High-efficient DSP chip
The digital Ti DSP controlling chip provides precise data processing capability with excellent performance in output
and reliability.


Outstanding electric property
The efficiency of the machines is as high as 93% and reaches over 98% in the ECO mode, which can help reduce the
power loss of UPS. Because of the technology of IGBT FM intelligent rectifier and inverter is used , the input power
factor is as high as 0.99,and the input current harmonic wave is as low as 3%,which makes the output voltage electric
property more extraordinary.
Powerful overload capacity: the ups can work normally up to 10 mins under the condition of 110-125% load and 1

minute in load of 125-150% . It also has the output short circuit protection capability.


MODELXPC 3110LXPC 3115LXPC 3120L
Rated Power10KVA/8KW15KVA/12KW20KVA/16KW
INPUT
Phase3W+N+G
Input Voltage(207-475)VAC
Input Frequency(46-54)Hz
Input PF>0.95
Bypass voltage(302-437)VAC
OUTPUT
Output Voltage220VAC±1%
Output Power Factor0.8
Output FrequencyNormal mode:same with utility power
Battery mode:49.9~50.1Hz
THDTHD<3% (linear load);THD<5% (non-linear load)
Transfer TimeNormal to battery mode: 0ms
Bypass mode to normal : 0ms
Overload Capabilityload≤105±5%:normally run;normal mode,turn to normal mode after overload disappearing
105±5%<load≤135±5%:60s
135%≤load≤150±5%:30s >150%:0.1s
BATTERY
Voltage192Vdc
Charging voltage220Vdc
Overvoltage230Vdc
Charging Current2A/4A(L type)
SYSTEM
Efficiency>92%
CommunicationLCD display+RS-232 + Intelligent slot
Restart FunctionAfter turning off due to cut off voltage of battery, UPS will restart
when voltage is in (302~437Vac) and frequency is in (47~53Hz).
Noise (1m front)<45dBA<50dBA
Operation Temperature0°C to 40°C
Humidity0~95% non-condensing
Storage Temperature-40°C to 50°C
Altitude1000m
Dimension(WXDXH)248×500×616
Weight(kg)273535
Specification is subject to change without prior notice.


Q:How does PLC use UPS?
PLC, like other electronic products, has different powers, with enough sizes of UPS,Generally requires more than equipment, maximum power +30% is safe
Q:The server is the highest rated power power power 500W power 270W 400W actual computer hardware over time with 12 hard disk so 300W with an optical transceiver to 320W display to unplug the server after power failure in the company of our own and run the web site to prevent power which can maintain 8 hours of running the best server is the 12 hour UPS brand does not need to be too good not to use enough often cut occasionally can be added:
In fact, a brother said the truth you load the ability to charge low power UPS did not reach the example of APC SU series machine 48V good for 8 hours with UPS configuration results 1 hours are not up to the person to suggest that you should be able to match the actual 3K suggest you brand Santak because Santak is 8 a group should be charged
Q:Can UPS power turn DC48V into AC220?
According to human interface of the UPS power supply by super intelligent power management humanization indicator panel composed of a small LCD system, provide clear overall UPS operation, electricity, battery, output, load and machine status information can be displayed through the LCD panel, greatly facilitate the operator and users. Through the RS232 interface to implement remote monitoring, and has the system self-test function, timing switch machine function, a variety of different state detection, alarm function, and become a truly intelligent UPS.
Q:How old is the 12 volt car inverter in use?
UPS has the power inverter in working state, the external alternating current into direct current through the circuit, then through high quality inverter to convert DC to high quality sine wave AC output to the computer. The main function of the on-line UPS in the power supply condition is to regulate voltage and prevent radio wave interference. In the power failure, the standby DC power supply (battery) is used to supply the inverter. Because the inverter is working all the time, there is no switching time problem. It is suitable for occasions where the power supply is strictly required. A major advantage of online UPS power supply is different from the backup power supply for a long, usually for a few hours, also have to ten hours, its main function is to allow you to be working as usual, in case of power failure obviously, because of its special function, the price is clearly a big section. This on-line UPS is more suitable for computers, transportation, banking, securities, communications, medical, industrial control and other industries, because computers in these areas generally do not allow blackouts.
Q:What is dynamic UPS?
The definition of interactive UPS power is: when the electric power in the range of about 150~264 volts, it provides users with the ferromagnetic resonance voltage regulator or the transformer tap processing General Electric Power (AC power supply the actual use of low quality power supply by this means: the frequency fluctuation, from general electric the power grid by "harmonic pollution" and the formation of high distortion degree and on interference from the power grid is user) for this UPS, only when the power supply voltage below 150 volts or higher than about 264 volts, it is possible to the user to provide the real "UPS inverter high quality sine wave power.
Q:UPS will burn down in those cases? Is it because the voltage of the mains voltage exceeds the input voltage range? Or because the percentage of the load is too large?
The UPS of the big brand will not burn out beyond the input voltage range and will not burn if the percentage of load is too large. Because UPS has the self-protection function. Voltage and load are out of range and UPS does not work. 90-270 access 380UPS does not work. Not burn. Unless you sell fakes. Generally burned is the aging of components, or internal dust, static and other internal causes of UPS. I don't know the Shanzhai UPS. 380 input with 220 city electricity will not burn, when the voltage is too low, the battery power supply UPS work properly.
Q:What's the difference between online UPS and pure online UPS?
This UPS uninterruptible power supply has the inverter in working state, it first through the external circuit AC into DC through high quality inverter to convert DC to high quality sine wave AC output to the computer. The main function of the online UPS in the power supply condition is to regulate voltage and prevent the interference of the electric wave. At the same time, the management of the battery is managed. In the case of power failure, the standby DC power supply (battery) is used to supply the inverter. Because the inverter is working all the time, there is no switching time problem. It is suitable for occasions where the power supply is strictly required.
Q:Can the power supply of the ups supply the lighting continuously?
As long as the battery is large enough, it is theoretically possible! General UPS power supply, according to the needs of the equipment to configure the appropriate battery, the time can range from 15 minutes to 12 hours! General power is relatively large load only about half an hour, and the longer the backup time, the higher the battery cost, small power load, such as monitoring, can generally be back up, 10-12 hours can be...
Q:What is UPS? What's the effect?
UPS is for some more important electrical equipment to provide uninterrupted power supply equipment, specific introduction, there are many online
Q:What is the difference between EPS and UPS functions?
Online UPS when power supply is normal, the rectifier provides DC voltage to the inverter by electricity from the inverter to provide AC power load, power anomaly in the city when the inverter powered by battery, the inverter always in working condition, ensure uninterrupted output. The utility model is characterized in that the utility model has the advantages of extremely wide input voltage range, no switching time, stable output voltage and high precision. The utility model is especially suitable for occasions with high power supply requirements, but the cost is higher. At present, UPS with power greater than 3KVA is almost all online UPS.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords