Hot Sales Smd 3014 Led Strip 12V 54Cm 54Leds 4Mm Wide
- Loading Port:
- Shenzhen
- Payment Terms:
- L/C,T/T
- Min Order Qty:
- 50 Pcs pc
- Supply Capability:
- 100000 Pieces Per Month pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Specifications
Work voltage | DC12V |
Working current ( one meter): | 540mA |
Standard length | 540mm per piece(Size is customizable.) |
PCB Width | 4MM |
Available Color | White, Warm White,Cold white |
Lighitng angle | 120 degree |
led rigid strip | SMD5050/3528/5630/7020 |
All parts | Aluminum pcb and LEDs (54pcs) |
CRI | :>80% |
Beam Angle | 120 degree |
Light decay | Less than 5% after 1000 hours constant work |
Protect range | non-waterproof or waterproof IP65 andIP68 |
Power | 6.5W |
Warranty | 2- 3 years |
Life Span | 50,000-80,000 hours |
Hight Lumen | 650lm/pc |
Apllications
1. LED super thin light box
2. Indoor decorative lighting and backlighting
3. Emergency hallway lighting
4. led pane light 1200*300mm (many sizes, 300*300mm,300*600mm,600*600mm)
5. Indoor/outdoor illuminated signs and advertisements
6. Backlighting for larger size ad-signs
7. Elegant interior decoration
8. Nice accent lighting lamps
9. Landscape outlines, etc.
10. Signal lighting
Note:
1. The SMD light ribbon itself and all its components many not be mechanically stressed.
2. Assembly must not damage or destroy conducting paths on the circuit board.
3.Installation of LED modules (with power supplies) need to be made with regard to all applicable electrical and safety standards. Only qualified personel should be allowed to perform installations.
4. Correct electrical polarity needs to be observed, Wrong polarity may destroy the ribbon.
5.Parallel connection is highly recommended as safe electrical operation mode, Serial connection is not recommended, Unbalanced voltage drop can cause hazardous overload and damage the ribbon.
6. Please ensure that the power supply is of adapters power to operate the total load.
7.When mounting on metallic or otherwise conductive surfaces, there needs to be an electrical isolation points between ribbon and the mounting surface.
8. Pay attention to standard ESD precautions when installing the ribbon.
9.Damaged by corrosion will not be honored as a materials defect claim, it is the user’s responsibility to provide suitable protection against corrosive agents such as moisture and condensation and other harmful elements.
Delivery:
Shipping Service | Estimated Delivery Time |
DHL | 2-8 business days |
FedEx | 3-8 business days |
TNT | 2-10 business days |
UPS | 1-7 business days |
EMS | 6-14 business days |
ePacket | 7-12 business days |
China Post Air Mail | 7-15 business days |
China Post SAL | 14-30 business days |
By Air | 3-10 business days |
By Sea | 30-40 business days |
1. 3-5 business days for Sample Orders; 7-30 business days for Bulk Orders.
2. "Business days" means Monday-Friday, excluding holidays.
3. DHL and UPS cannot ship to military or P.O. boxes address.
4. The Shipping Service above is for reference only, for any other questions, please feel free to contact us.
- Q: How does the LED band replace the tube?
- The light band and the tube are the same. You can choose the LED model, so there is no limit to the type of the light band
- Q: LED lights with 12 volts a meter, how many W?
- According to the specific amount, then a lamp will know how W, the cumulative
- Q: What is the wattage of the LED lamp with one meter?
- Each band must be equipped with a dedicated plug (plug with a transformer); when connected, be sure to remove the transparent plastic cover, and then try the lights and then cover. It must not be connected directly with a cover, so it is easy to short-circuit!
- Q: Does the LED belt need 3C certification?
- LED lamp belt is not 3C certified, LED lamps to do 3C certification; I did LED lamp 3C certification, but there is no certification of LED lamp
- Q: How much is the output voltage of the LED lamp belt driver?
- 3V to 36V, more LED products technical problems, consult the selected lighting
- Q: 5050LED lights with 14.4W/1 meters, power 12V-360W can take 25 meters? I mean RGB, if it's connected to the color
- For the second problem, 360/12 = 30A, the current large, general electric wire is unable to load the current so high, and you want to see in the light there is no equipment line, if not, it should be every meter to connection to the power supply, if any, every four to five meters should also be wiring to the power supply voltage, so as to ensure the basic stability of the position
- Q: What kind of power supply should the LED light belt be equipped with?
- LED lights should be configured with dedicated DC power supplies.DC power supply is divided into two kinds of voltage source and current source;In general, a fixed number of LED lights can use a DC voltage source, the voltage source is relatively simple, many varieties, the corresponding LED lamp group should work in parallel. If the LED lamp group is connected in series, once one of the circuit breaks, the fault will be caused, so the light is not on.
- Q: What happens if the 12vled lights are connected to the 24V transformer?
- LED is called a light emitting diode. When communicating, it actually flashes at 50 times per second, and it continues to shine when in direct current. Life would not be affected because the temperature of the LED would affect its life. So it may be longer to use under communication (of course, this is only theory).
- Q: Does the LED low voltage lamp belt belong to the luminaire?
- LED low voltage light belt does not belong to lamps and lanterns, and belongs to decorations.
- Q: LED how to connect the lamp band, 12 volt battery is not damaged
- Direct contact will burn. The three should be connected in series, with 150 ohm resistors in front (power not less than 0.06 watts). Note the positive and negative poles, and the gap is negative.
Send your message to us
Hot Sales Smd 3014 Led Strip 12V 54Cm 54Leds 4Mm Wide
- Loading Port:
- Shenzhen
- Payment Terms:
- L/C,T/T
- Min Order Qty:
- 50 Pcs pc
- Supply Capability:
- 100000 Pieces Per Month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords