• High Luminous LED Compact Light Directly from Factory System 1
  • High Luminous LED Compact Light Directly from Factory System 2
  • High Luminous LED Compact Light Directly from Factory System 3
High Luminous LED Compact Light Directly from Factory

High Luminous LED Compact Light Directly from Factory

Ref Price:
get latest price
Loading Port:
China main port
Payment Terms:
TT OR LC
Min Order Qty:
50 pc
Supply Capability:
8000 pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Specification

Color Temperature:
Pure White
Size:
535mm *43.5mm *23.5mm
Lamp luminous flux(lm):
2000
Type:
other
Body material:
PC
Working lifetime(Hour):
25000
Power(W):
22W
Certification:
UL
Working Temperature(℃):
-20-45
PF:
>0.95
Input voltage(V):
100-277
CRI (Ra>):
>70
Warranty:
three years
IP Rating:
IP40

1.Technical Specification


Model   No.JCD01A220022JCD01A220022(INT)
Input   Voltage(V)AC100~277AC100~277
Dimming   Voltage1~10V\
Cut-off   Voltage0~1V\
Rated Power(W)2222
Rated   Lumen(lm)20002000
IP LevelIP40IP40
Operating   Ambient Temperature(℃)-20~45-20~45
Overall   Dimension(mm)535×43.5×23.5535×43.5×23.5
Weight(kg)0.4kg0.48kg


2.Product Features


1) Integrated design, compacted structure, convenient   installation;
2) Special surface treatment technology , beautiful and scratch resistant; 
3) Employ V0 fire-resistance level PC material for non-metal parts;safety;
4) Luminous efficiency can be more than 90lm/w; UGR<17;< span="">
5) Patented heat dissipation technology; temperature increase on the heat             sink<15℃;< span="">
6) Noise<45db;< span="">
7) High quality driver design,well-protected functions, long life time.


3.Beam Angle











Q: How do the fluorescent tubes fail?
It's not hard to repair, it doesn't have the value of maintenance.
Q: But what happens when you don't take a ballast and replace it with a traditional fluorescent lamp?
Days without a day LED fluorescent lamp of a large number of exported to Japan, the glare of the LED fluorescent lamp tyjb tian yuan festival safeguards through the efforts of the company research and development team this fluorescent lamp conquered the world's most rigorous German, also conquered the world's most critical Japanese... This product distinctive features are: (1) the light is very close to the common fluorescent lamp, the light is very soft and high brightness not dazzling, can't see the point light source, from the apparent anti-oxidation of gold plating technology on the electrode head, radiator with wiredrawing alloy processing, lamp holder to adopt green PC fireproof material, lens face processing, PC cover using nanometer ultra light manufacturing process. That compares with the highest levels of performance in South Korea and Japan. Craftsmanship reveals the aristocratic qualities of flagship products. Exclusive use of high heat conduction UL certified rich copper plate thermal conductivity 2.6 w/m.k. It is 13 times higher than the thermal conductivity of 0.2 watts/m.k. It is more than two times the heat transfer coefficient than the normal aluminum plate thermal conductivity of 1.0 w/m.k, and 13 times lower than the thermal lamp of a single fiberglass board. It is more than twice as low as the thermal light of the other aluminum plate. The cost of the copper plate is half as low as the aluminum plate. The power source adopts the super long life ruby capacitor, the realization and the light-emitting diode synchronous life, the real high performance, high life
Q: Fluorescent lamp double lamp tube wiring method
Leds that do not normally require special orders are mostly built with built-in power, which is directly available. Most can only need to remove the starter on the traditional stent line (is a cylinder bracket highlighted below) mount tubes can be used, if not yet so could you use the stent is a relatively new "electronic" will be a little trouble need you open the stents to get inside the ballast also take off to the inside of the line directly connected to the utility, LED bulb is directly at the mains. Of course, if you understand the circuit and you're not afraid of trouble, it's advisable to remove the "regenerator", because the "ballast" is a power drain.
Q: Do the fluorescent tubes save electricity for 10 minutes, or do they save electricity in a split second?
If you turn on the lights for a second, it won't take more than 10 minutes. When any lamp is lit, there is a loss to the filament, so a temporary turn off the light is unnecessary.
Q: How long does the energy-saving daylight lamp tube change?
If a square originally needed a single one to reach the requirement, it now needs to be increased to three to achieve the original brightness. It's normally 3X36 = 108 watts per square root of 36 watts. It turns out that electricity consumption is only 0.036 degrees per hour and now it is 0.108 degrees to achieve the same brightness. The more you open it, the more energy you will consume. Besides, this is without causing damage to the case, the general tubes to use fixed number of year will gradually damaged, bad time change time will be more trouble, so as to compare and calculate a one-time change.
Q: Who knows about the fluorescent light of 40w, how many w's LED bulbs can replace or exceed its brightness?
You can replace it with 18W leds, which are about the same.
Q: What's the difference between a single input and a double-end input?
Single end input is the only one that has a connection Double-end input is designed to be able to use the interface of the traditional lamp holder.
Q: How to connect the power supply when the LED lamp is energized? The search is to get a wire directly from two ends? Do you need to be able to distinguish positive and negative?
Are you asking for 220V power? If you don't have to be a plus or minus, because the ac is not a plus or minus, you can just plug it in. Hope can help you!
Q: How does the lamp line connect
If it is converted by fluorescent lamp tube into LED lamp tube, want to remove the regenerator and the ballast. The two wires connected to A1 and A2 have been turned into a thread, and the two wires connecting B1 and B2 are also twisted into one line and are connected to the two ends of 220V respectively.
Q: Now the home decorates is to use LED good or the good of the lamp tube
Now the home is decorated with LED. LED lamp tube also commonly known as the light tube, daylight lamp tube, its illuminant USES LED as the light body. The traditional fluorescent tube, also known as fluorescent lamp, lamp on both ends of each have a filament, inside the tubes filled with tiny amounts of argon and the thin mercury vapor, tubes coated with phosphor, on the wall between the two filament gas when conducting an ultraviolet, the phosphor emit visible light. Led bulbs have many advantages, such as general lighting, office buildings, shopping malls, restaurants, schools, homes, factories, etc. The lamp tube is a kind of fluorescent lamp (or fluorescent lamp, light tube, fluorescent tube), the diameter is 5/8 inches, about 16mm, belongs to the gas discharge lamp. It USES electricity to activate mercury vapor in argon or neon gas, forming plasma and emitting short wavelengths of ultraviolet light, causing the phosphor to emit visible fluorescence to illuminate. The normal fluorescent tube is made of glass, with a socket at both ends to connect the power source and the fixed fluorescent tube. The fluorescent lamp tube is a gas discharge luminescent light source, according to the pipe size of T12, T10, T8, T6, T5, T4, T3, etc., the current T8, T6, T5 are mainstream. Especially since the T5 fluorescent lamp tube, the technical performance is advanced, the light effect is high, the lighting quality and the effect is excellent and so on the technical characteristic, is replacing the T8 fluorescent lamp tube with the faster speed.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches