Favorites Compare Professional LED injection module light
- Loading Port:
- Shekou
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- 100000 PCS/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
IP66 LED module full color 3 SMD-LED with lens
Lens Make 20% Brighter, and reducing overal system costs
LED Type | 2835 SMD LED / 3 LED MODULE | |||||
View angle | Lens make 160 Degree | |||||
Lumen | 66 | 66 | 16.2 | 37.8 | 10.8 | 18.9 |
Warranty | 5-year. | |||||
Voltage(V) | 12V DC | |||||
Current(mA) | 60(single led module) | |||||
Consumption | 0.72W(single led module) | |||||
IP | 66 | |||||
Color(k/nm) | 6500 | 9000 | 623~625 | 515~517 | 462~464 | 590~592 |
Size | 81x14x5mm | |||||
Operation Tem | -25~60 degree | |||||
Part No | RZFT7213-3W2835 | RZFT7213-3CW2835 | RZFT7213-3R2835 | RZFT7213-3G2835 | RZFT7213-3B2835 | RZFT7213-3Y2835 |
Features:
Lens make 160 degree viewing angle, higher effciency
Extremely luminous, with 66lm brightness
Energy saving and environmental friendly
Various colors are available
Long lifespan: More than 50, 000 h, 5 years warranty
Aplication:
Channel letter,reverse letter with waterproof requirement
Outdoor light box
Advertising leds sign lighting
Outdoor architectural lighting and decoration
Large area back lighting
Other lighting projects
Quick Selection Guide: LED Injection Module For Channel Letter
Depth of channel letter(mm) | LED Pitch(mm) | Density(pcs/m2) | Surface brightness(Lux) |
50~60 | 120 | 100 | 4200~4800 |
60~80 | 140 | 55 | 2200~2600 |
100 | 160 | 40 | 1700~2000 |
120 | 180 | 29 | 1300~1600 |
150 | 210 | 24 | 900~1200 |
1. The test results are based on 3mm thickness white acrylic panel and 6500K led module
2. Blue line is best product performance at Max LED pitch
- Q: Led full-color light string and how to control wiring
- 5 line DMX512 full color string, 2Po, 2 access, and access control site
- Q: 220vled water lamp string how to connect, that is, 220 of the electricity
- The triode acts as a switch in the circuit, and when the circuit is through, the left LED is first lit. The base is connected with a capacitor to connect the collector of the next triode.
- Q: The number of lights in the LED string
- In general, 1210 specifications of the band is 60 LED per meter, 5050 specifications of the band is 30 LED per meter, the special has 60 LED per meter.
- Q: What's the average luminous current of an ordinary LED lamp string?
- If the lamp light current series is their rated current,
- Q: How does the LED light string flash?
- What kind of light? What about the flash?If you are talking about the pulse drive mode of LED, then it is for heat dissipation and energy saving.
- Q: Section LED lantern, no controller, can shine principleTwo now reduced brightness string string
- Led 2 polar tube inside chip oscillator circuit, and the general appearance led 2 polar tube without distinction, only connected to the power supply of two kinds of color turns light, 1 seconds, I bought the 5MM red, blue autoflash. From the appearance of the series, but not necessarily in series
- Q: Example: if I want to do a 40 head low voltage lamp string, do 10 lights, 1 loop, transformer is 150MA, then how can I calculate the resistance? The grid is 60 Hz of China's power grid! Give a formula, and then count the examples. What is it?! Thank you
- Diode products cannot be calculated by resistors.
- Q: Rated voltage of LED lamp string
- You are the light string and see how much you a lamp, the lamp voltage for LED in 3.0-3.4V, for intermediate values of 3.2V, N=220/3.2=68.75 so many beads. In fact, we are in terms of LED is a DC device, there is no voltage rating, mainly to see his current value, the work must be steady flow. The power 0.06W LED current is 20MA, the power 0.2W LED current is 60MA, the power is 0.3W, the LED current is 100MA, the power is 1W, the high power LED current is 300-350MA, and so on in turn, ah, I=P/U
- Q: What is the connection distance of the LED light string?Be specific
- The connection distance is 15 meters. If the connection distance is exceeded, the LED light string is easy to heat, and the service life of the LED light string will be affected during use
- Q: Why are there three lines for the controller of the LED light string? What are they?
- Common positive (red line +) is the positive pole for each street lampThree road cycling (blue line) this four lines are respectively connected with the four colors of LED tube anode side run. When the positive pole is connected to the common cathode, remember that the resistor must be connected first to connect to the positive electrode of the LED tube. The bright output (white) is the word to make it bright
Send your message to us
Favorites Compare Professional LED injection module light
- Loading Port:
- Shekou
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- 100000 PCS/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords