Solar Battery REX Series Introduction

REX battery  is designed for Renewable Energy Sources such as  Solar and Wind Power. REX protects  our environment using Green Technology and  benefits the World's Urban  and Rural Population by Generating  Power Economically from a Clean Source  of Energy.

REX is a product developed  by our R&D with  an " eXtra" in Performance  and Life Span.
The REX series batteries are ensured the quality with  QA  system according to the ISO9001&ISO14001 standard.

 

Solar Battery REX Series for Solar and Wind Power  REX-1000

Solar Battery REX Series for Solar and Wind Power  REX-1000

Solar Battery REX Series for Solar and Wind Power  REX-1000

Solar Battery REX Series Features and Benefits

  • Long life design for both  cyclic and float applications

  • Superb security and  reliability

  • Robust design inside and out

  • Excellent deep discharge  recovery fast recharge performance

  • Extra long back-up times

  • More cost effective than  nearest equivalent


Type:

  REX-1000

Voltage:

  2V

Nominal Capacity:

  1000Ah(C10)  1000Ah(10 hours rate:)

Length:

  231mm

Width:

  282mm

Height:

  396mm

Height with termial:

  408mm

Weight:

  76Kg

Solar Battery REX Series Compliant  Standards

  • IEC60896-21/22

  • IEC61427

  • BS6290 part 4

  • Telcordia SR4228

  • Eurobat guide

  • UL

  • Manufactured under system  ISO9001(TUV) and ISO14001

Solar Battery REX Series  Battery  Installation Compliant with

  • EN 50272-2 or local  equivalents

Solar Battery REX Series Main  Applications

  • Renewable energy source such  as solar and wind power

  • Telecom exchange and transmission  system

  • Mobile communication system

  • Power plant and power  transformer system

  • Navigation aid signaling  system

  • Radio and broadcasting  station

  • Emergency lighting system

  • Other standby, cyclic system

Solar Battery REX Series Installation  and Operation

  • Recommended float charge voltage  2.27V per cell at 25oC
     compensation in function of temperature -3mV/oC/cell

  • Cycle and equalize charge  voltage: 2.35V per cell at 25oC
     compensation in function of temperature -5mV/oC/cell

  • CC-CV charge current  unlimited, otherwise 150A  max. if T>25oC

  • Preferred operating  temperature range 15oC to 25oC(68oF to 77oF)

  • Maximum operating  temperature range -40oC to 50oC(-40oF to 122oF)

  • A separate battery room is  not necessary

  • Reduced maintenance no water  addition required.

  • Design float life: 20 years at 25oC (77oF)

Solar Battery REX Series Construction

  • Positive plate --- Reinforced grids in a corrosion-resistant pure  lead, high tin, low calcium alloy

  • Negative plate --- Lead-calcium alloy grid

  • Separator ---  High  density microporous glass mat with low electrical resistance

  • Container & lid --- High strength ABS(HB). Optional flame retardant F V-0 and halogen-free versions available

  • Electrolyte --- Sulphuric acid with a density of 1.28g/ml  absorbed in AGM

  • Terminal design --- Patented leak resistant seal configuration with  brass insert

  • Safety valve --- Calibrated opening pressure , the valve  equipped with flame arrestors for  increased operational safety and service life.

 FAQ

How long a battery can last?

The service design life of a battery are vary considerably with how it is used, how it is maintained and charged, temperature, and other factors.

Do batteries self-discharge when not in use?

All batteries, regardless of their chemistry, self-discharge. The rate of self-discharge depends both on the type of battery and the storage temperature the batteries are exposed to. However, for a good estimate, Narada batteries self-discharge approximately 4% per week at 80ĄăF.

What is battery cycle life?

One cycle of a battery is a discharge from full charge to full discharge and a return to full charge again. The total number of cycles a battery can perform before failure is called its Cycle Life. Moat battery manufacturers will not discus the Cycle Life of their product. Many advertised Deep Cycle batteries have not been tested, or, which is the case with cranking batteries, were never designed for long Cycle Life .

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What is the meaning of the battery above 12v65Ah?
12V represents the rated voltage. 65Ah indicates that the battery capacity (ie 1 ampere current can be used for 65 hours).
Q:The role of the battery?
Battery is a kind of battery, its role is to be able to save the limited power, in the right place to make 6v4ah emergency light battery. Its working principle is to convert chemical energy into electricity.
Q:Battery 200ah / 104 what does that mean?
This should be refers to 2V200AH battery 104, power with the 220V. Lead-acid battery nominal voltage is 2V / (each or monomer), but in fact will be higher than 2V, so the actual use and charging equipment for the matching will use 104, also useful 103, also useful 108 Only.
Q:What are the advantages of maintenance-free batteries?
Maintenance-free battery because of its normal charging voltage, the electrolyte only produce a small amount of gas, so throughout the use of the need for the addition of distilled water, in the normal charging system, do not need to remove the charge from the removal. But in the maintenance of the proportion of its electrolyte should be checked.
Q:What battery does the van use?
The battery is mainly composed of tube positive plate, negative plate, electrolyte, separator, battery compartment, battery cover, pole, injection liquid cover and so on. The electrode of the exhaust type battery is made of lead and lead oxide, and the electrolyte is an aqueous solution of sulfuric acid. The main advantage is the voltage stability, the price is cheap; the disadvantage is lower than the energy (that is, per kilogram of battery storage power), short life and routine maintenance frequently. Old ordinary battery life of about 2 years, and the need to regularly check the height of the electrolyte and add distilled water. However, with the development of science and technology, lead-acid battery life becomes longer and maintenance is also more simple.
Q:How to determine the battery is good or bad?
Observe the battery electrolyte is turbid, turbidity that the battery positive plate softening. Observe the bottom of the battery whether there is sediment, if the plate off the battery capacity has been inadequate. Hand hit the battery two electrode piles If you hear an empty voice that pole pile and plate break. With a thick wire short-circuit positive and negative pile observation of the battery filling holes, such as the discovery of a bubble appears that the interval has been damaged.
Q:What is a maintenanceable battery?
Maintenance-free battery due to its own structure on the advantages of electrolyte consumption is very small, in the life of the basic need not add distilled water.
Q:Lead-acid battery how to maintain?
When receiving the battery should first check whether the phenomenon of short circuit, first short circuit repair and then fill the distilled water.
Q:How is the capacity of the battery defined?
The capacity of the battery unit is AH (safety) is the product of current and time.
Q:What kind of battery is divided into?
Ordinary battery: ordinary battery plate is composed of lead and lead oxide, the electrolyte is sulfuric acid aqueous solution. Its main advantage is the voltage stability, the price is cheap.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range