• Lead Acid Battery the Acme.F Series Battery 12NDF100 System 1
  • Lead Acid Battery the Acme.F Series Battery 12NDF100 System 2
  • Lead Acid Battery the Acme.F Series Battery 12NDF100 System 3
  • Lead Acid Battery the Acme.F Series Battery 12NDF100 System 4
  • Lead Acid Battery the Acme.F Series Battery 12NDF100 System 5
Lead Acid Battery the Acme.F Series Battery 12NDF100

Lead Acid Battery the Acme.F Series Battery 12NDF100

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT or LC
Min Order Qty:
2000 unit
Supply Capability:
100000 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Range summary


The Acme.F range front access valve regulated lead acid batteries is designed with real front access structure. The state-of the-art internal and external design ensures Acme.F the high reliability and makes the installation squite simple and safe when placed on a standard relay rack tray or in a closed cabinet.
 Acme.F range VRLA battery is designed with high energy density and suitable for 19". 23" rack or cabinet.
                                    

Acme.F also offers options of top connection and side of monoblocs connection.

The terminal protector for Acme.F batteries are designed with special probe hole allowing safe and easier voltage testing and suitable for all connection means.

The specially centralized venting system ensures the small gas be vented our of the closed cabinet
                                     

The prmium Acme.F batteries are ensured  the quality with NARADA's QA system according to the ISO90001 and ISO14001 standard.









Technical features

  • Real front-access terminal connections for fast and easy installation and maintenance

  • Easy on easy off multi-purpose design ternimal protector

  • Suitable for 19", 23" racking or cabinet

  • Proven excellent special lead-tin-calcium formula alloy for grids and plates

  • Mircoporous glass mats in low resistance as separator

  • Flame retardant ABS material container and cover compliant with UL94 V-0

  • Self-regulating pressure relief valve

  • 12+ years expectant Life under full  float service at 68oF(20oC)

     

 

Type:

  12NDF100

Voltage:

  12V

Nominal Capacity:

  100Ah(C10)  100Ah(10 hours rate:)

Length:

  390mm

Width:

  105mm

Height:

  287mm

Height   with termial:

  287mm

Weight:

  33Kg

Compliant standards
Designed to be compliant with:

  • IEC 60896-2

  • BS 6290 Part 4

  • Telcordia SR-4228

  • EUROBAT GUIDE

  • UL

  • Manufactured under system ISO9001 & ISO14100 by NARADA

Battery installation compliant with:

EN 50272-2 or local equivalents

Main applications

  • Telecom standby and cyclical applications

  • UPS

  • Power system

Products characteristics:

  • Recommended float charge voltage for 12V battery: 2.25Vpc at 77oF(25oC)

  • Self discharge rate: < 2% pre month at 77oF(25oC)

  • Design life: more than 12 years at 68oF(20oC)

  • Shelf life: 6 months at 68oF(20oC)

  • Valve regulated system, no water addition needed

FAQ 

How long a battery can last?

The service design life of a battery are vary considerably with how it is used, how it is maintained and charged, temperature, and other factors.


Are lead acid batteries recyclable?

Lead acid batteries are 100% recyclable. Lead is the most recycled metal in the world today. The plastic containers and covers of old batteries are neutralized, reground and used in the manufacture of new battery cases. The electrolyte can be processed for recycled waste water uses. In some cases, the electrolyte is cleaned and reprocessed and sold as battery grade electrolyte. In other instances, the sulfate content is removed as Ammonia Sulfate and used in fertilizers. The separators are often used as a fuel source for the recycling process.


What is battery cycle life?

One cycle of a battery is a discharge from full charge to full discharge and a return to full charge again. The total number of cycles a battery can perform before failure is called its Cycle Life. Moat battery manufacturers will not discus the Cycle Life of their product. Many advertised Deep Cycle batteries have not been tested, or, which is the case with cranking batteries, were never designed for long Cycle Life .

 

Storage Battery  is a kind of chemical energy directly into electrical energy device, is designed according to the rechargeable Battery, it recharge by reversible

chemical reactions, usually is refers to the lead-acid Battery, it is one of the Battery, belongs to the secondary Battery.How it works: when charging use external

power to make the internal active substances, to store the electric energy to chemical energy, need discharge to convert chemical energy to electrical energy output,

such as mobile phone battery is commonly used in life.Accurate charging method can maintain the life of the battery, there are some in the process of charging charging

error such as: early charge, to supplement the charging, battery charging, charging polarity reverse filling, etc.Right electric device charging method was that the

positive battery anode, battery cathode to connect power cathode;Then initial charge in two stages: first with the initial charging current into the electrolyte to

emit bubbles, the single voltage up to 2.3 ~ 2.4 V.Then reduced to 1/2 at the beginning of charging current, continue to electrolyte filling out severe bubbles, stable

voltage for 3 h.All the charging time is about 45 ~ 65 h;Should be used in the process of charging the electrolyte temperature measured in current by half, stop

charging or cooling method, the temperature control in 35 ~ 40 ℃, when the initial charge, if the proportion of the electrolyte illegal, application of distilled

water or electrolyte specific gravity of 1.4.Adjust the recharging after 2 h, until density conform to the rules.

Q:What are the technical parameters of the battery?
Battery capacity is defined as ∫ t0tdt, theoretically t can be infinite, but in fact when the battery discharge is lower than the termination voltage continues to discharge, which may damage the battery, so t value is limited, the battery industry, in hours (h) Battery sustainable discharge time, feel the C24, C20, C10, C8, C3, C1 and other nominal capacity value.
Q:Battery 200ah / 104 what does that mean?
This should be refers to 2V200AH battery 104, power with the 220V.
Q:What is the difference between a maintenance-free battery and a conventional battery?
Different materials will produce a different phenomenon: the traditional battery in the course of the use of the phenomenon of liquid reduction occurs, because the antimony on the grid will pollute the sponge on the negative plate of pure lead, weakened after the full charge of the battery Electromotive force, resulting in excessive decomposition of water, a large number of oxygen and hydrogen, respectively, from the positive and negative plates to escape, so that the electrolyte reduced. With calcium instead of antimony, you can change the fully charged battery back electromotive force, reduce the overcharge current, liquid gasification rate decreases, thereby reducing the loss of electrolyte.
Q:How to deal with waste batteries?
The rest of the various types of waste batteries are generally shipped to a special toxic, hazardous landfill, but this approach not only cost too much but also cause waste, because there are many useful raw materials available.
Q:80ah how much battery storage capacity?
Is 80AH. Understood to discharge at 80 amps for about 1 hour (but not to say that after 1 hour is finished, there is still electricity). In theory, this is your battery power.
Q:What are the advantages of maintenance-free batteries?
Maintenance-free battery because of its normal charging voltage, the electrolyte only produce a small amount of gas, so throughout the use of the need for the addition of distilled water, in the normal charging system, do not need to remove the charge from the removal. But in the maintenance of the proportion of its electrolyte should be checked.
Q:What are the hazards of battery over discharge?
The battery discharge to the standard termination voltage when the internal resistance will become larger, the battery electrolyte concentration will become very thin, especially the battery plate micropores and battery plate surface these two points are almost neutral; battery over discharge because of Internal resistance will become larger, so the battery will appear inside the phenomenon of heat, the battery volume will appear fever expansion.
Q:How should the battery be well maintained?
Voltage check the state of the battery standard voltage should be maintained between 12.2 ~ 12.7V. If the voltage is too low should be charged, the charge should be kept small charge for a long time. Battery charging need to use a professional charger, the owner will not try to charge their own, the owner can only keep the engine running on the battery can be charged. If the battery aging should be replaced.
Q:Lead-acid battery how to maintain?
Along the battery cover on the exhaust hole, open the battery cover plate, some of the battery cover is APS adhesive, and some batteries are buckle connection, pay attention to open the cover when the cover plate The At this time you can see the six exhaust raft rubber cap.
Q:What battery does the van use?
The battery is mainly composed of tube positive plate, negative plate, electrolyte, separator, battery compartment, battery cover, pole, injection liquid cover and so on. The electrode of the exhaust type battery is made of lead and lead oxide, and the electrolyte is an aqueous solution of sulfuric acid. The main advantage is the voltage stability, the price is cheap; the disadvantage is lower than the energy (that is, per kilogram of battery storage power), short life and routine maintenance frequently. Old ordinary battery life of about 2 years, and the need to regularly check the height of the electrolyte and add distilled water. However, with the development of science and technology, lead-acid battery life becomes longer and maintenance is also more simple.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords